• Title/Summary/Keyword: 침출수 이동

Search Result 87, Processing Time 0.025 seconds

Leachate Treatment using Intermittently Aerated BAC-Fluidizing Bed (간헐폭기 생물활성탄 유동상에 의한 매립지침출수 처리)

  • Kim, Kyu Yeon;Lee, Dong Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.4
    • /
    • pp.136-147
    • /
    • 2005
  • Leachate from landfill sites contains high organics, chloride and ammonium nitrogen in concentration which might be potentially major pollutants to surface and groundwater environment. Most of landfill leachate treatment plants in Korea consist of biological processes to remove BOD and nitrogen. However, the efficiencies of refractory organics removal, nitrification and denitrification have not met frequently the national effluent regulation of wastewater treatment facility, especially in winter season. Simultaneous removal of organics and nitrogen from leachate is strongly necessitated to meet the national regulation on effluents from leachate treatment facilities. The intermittently aerated biological activated carbon fluidized bed(IABACFB) process was applied to treat real landfill leachates containing refractory organics and high concentration of ammonium nitrogen. The IABACFB reactor consisted of a single bed in which BAC fluidizing and an aerating column. The fluidized bed is intermittently aerated through the blower located at the aerating column. Experiments were performed to evaluate the applicability of Intermittently Aerated BACFB for simultaneous removal of refractory organic carbon and ammonium nitrogen of leachate. Organics and ammonia nitrogen($NH{_4}{^+}-N$)are oxidized during the aerobic stage, and nitrite-nitrate nitrogen($NO{_x}{^-}-N$) are removed to nitrogen gas through denitrification reaction during anoxic state. The IABACFB reactor condition reached a steady state within 40 days since the reactors had been operated. The blowing mode of 60 min.-On/60 min.-OFF is more compatible to remove TOC and ($NH{_4}{^+}-N$) operated. The blowing mode of 60 min.-On/60 min.-OFF is more compatible to remove TOC and ($NH{_4}{^+}-N$) simultaneously than the mode of 30 min.-On/90 min.-OFF. The average removal efficiencies of TOC, the refractory organic carbon, and the average efficiencies of nitrification and denitrification were 90%, 75%, 80%, 95%, respectively.

  • PDF

Leaching Behavior of Vanadium and Possibility of Recovery of Valuable Metals from VTM Concentrate by Sulfuric Acid Leaching (바나듐함유 티탄철석 정광으로부터 황산 침출법에 의한 바나듐의 침출거동 및 유가금속의 회수가능성)

  • Joo, Sung-Ho;Shin, Dong Ju;Lee, Dongseok;Park, Jin-Tae;Jeon, Hoseok;Shin, Shun Myung
    • Resources Recycling
    • /
    • v.31 no.1
    • /
    • pp.65-77
    • /
    • 2022
  • A study was conducted in Korea on the leaching behavior and possibility of recovery of vanadium and other valuable metals from domestic vanadium titanomagnetite (VTM) by direct acid leaching. In this study, a VTM concentrate containing 0.8% V2O5 was used, and the ratio of magnetite to ilmenite was calculated as 1.9:1 by using the HSC program. The leaching behavior of vanadium from the VTM was similar to that of iron, and it was affected by the concentration of sulfuric acid and temperature. Further, titanium could be leached in the form of TiOSO4 at a temperature higher than 75℃. To improve the leaching efficiency of V, Fe, and Ti in VTM, reductive sulfuric acid and oxidative sulfuric acid leaching were performed. When Na2SO3 was used as a reducing agent, the leaching rate of vanadium was 80% of that in that case of leaching by sulfuric acid. Similarly, the leaching rate of titanium increased from 20% to 50%. When Na2S2O8 was used as an oxidation agent, most of the vanadium was leached, and the main residue found by XRD analysis was ilmenite. In studies on the possibility of recovering valuable metals, the selective extraction of metals is hardly achieved by solvent extraction from oxidation leaching solutions; however, in this study, Cyanex 923, a solvation extractant from reductive leaching solutions, could selectively extract Ti.

The Synthetic Study of Environmental Contamination at the Seokdae Municipal Waste Landfill in Pusan (부산 석대 생활폐기물 매립장의 환경오염에 대한 종합적 연구)

  • 김병우;정상용;이민희;이병헌
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.98-103
    • /
    • 2001
  • In order to understand the characteristics of leachate at the Seokdae municipal waste landfill in the Pusan city, the correlation between leachate pollution loading and volume of gas production. concentration of gas and subsidence of ground, the characteristical methos, geochemical analyses and laboratory column tests using samples of gases, leachate and surface soil of Seokdae waste landfill area. Through the analysis of water balance, leachate flow rate and pollution loading were estimated. Geistatistical analysis of four gas components ( $O_2$, C $H_4$, $H_2$S and CO) shows the possibility of ground subsidence around the group of a site with high concentration of gas. From geochemical analyses of leachate, EC and Total-Alkalinity of ground subsidence around the group of a site with high concentration of gas. From geochemical analysis of leachate, Ec and Total-Alkalinity were increased, and Cl, Cr, Mn, Cu, Zn, Cd and Pb were decreassed comparing to the part, and the type of water quality was Na-HC $O_3$ in trilinear diagram. It shows that biodecomposition of municipal wastes continues actively. From the analysis of water balance, the total leachate flow rate is about 465.11㎥/day and pure pollution loading of Cl, Mn and Fe are estimated to 223.8kg/day, 0.2kg/day, 0.3kg/day, respectively. The laboratory column test of residual soil and landfill soil shows 0.206cm and 0.019cm for linear velocity(equation omitted), 0.234 $\textrm{cm}^2$/min and 0.018$\textrm{cm}^2$/min for diffusion coefficient ( $D_{ι}$), and 1.136cm and 0.095cm longitudinal dispersion index ($\alpha$$_{ι}$), respective]y. It demonstrates that the delay time of contamination for residual soil is shorter than that of landfill soil.

  • PDF

Major plant nutrient-releasing patterns in the leachates from the soil incorporated rice hull biochar adjusted pH with dry fish powder (산도를 조절한 왕겨 바이오차와 어분 혼합물을 처리한 토양 침출수의 양분용출 패턴)

  • Jae-Lee Choi;DongKeon Lee;MinJeong Kim;JooHee Nam;ChangKi Shim;SeungGil Hong;JoungDu Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.3
    • /
    • pp.55-64
    • /
    • 2023
  • This batch experiment was conducted to investigate the patterns of major plant nutrients in the leachates from the soil that was incorporated with rice hull biochar adjusted pH with dry fish powder utilizing rice hull biochar for loading the soil microorganisms. The rice hull biochar adjusted pH between 6.0 and 7.0, and the mixture ratio of rice hull biochar and dry fish powder was 4:6. The treatments consisted of three; the soil incorporated with rice hull biochar non-adjusted pH with dry fish powder as control (RB + DF), the soil incorporated with rice hull biochar adjusted pH by pyroligneous acid solution and dry fish powder (RBP+DF), and the soil incorporated with rice hull biochar adjusted pH by citric acid solution and dry fish powder (RBC+DF). NH4-N, NO3-N, PO4-P, and K concentrations in the leachates were analyzed during incubation. The accumulated NH4-N and PO4-P concentrations in the leachates from the RBC+DF treatment were the highest during leaching periods. The highest accumulated NO3-N and K concentrations in the leachates from the RBP+DF treatment were observed. It observed that NH4-N and PO4-P were more released in the adjusted citric acid solution, but NO3-N and K were less released than those in the pyroligneous acid solution due to their low absorption capacity. Furthermore, it is necessary to investigate crop growth responses to the soil incorporated with adjusted pH rice hull biochar and dry fish powder for loading soil microorganisms.

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

Heavy matal removal in leaching water from the region buried tungsten tailing (중석광 폐재광미의 매립지에서 나오는 침출수 중의 중금속 제거)

  • Lee, Dong-Hoon;Oh, Sae-Gang;Choi, Choong-Lyeal;Park, Man;Choi, Jyung
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.3
    • /
    • pp.218-222
    • /
    • 2000
  • Wasted${\cdot}$rested mine areas give lots of effect on around-environmental changes after mining development. Leaching water at reclaimed land has been eluted from the solid components through physical, chemical, biological procedures by waters percolated through reclaimed site. The element analysis of waste tungsten ore tailing, leaching water analysis and removal of heavy metal by zeolite were performed to investigate the influent of acid rain on the released contents of H. M. The heavy metal contents in leaching water were determined to be As $1.21\;{\sim}\;1.54\;ppm$, Pb $0.11\;{\sim}\;0.15\;ppm$ and $SO_4\;^{2-}$ was $302\;{\sim}\;378ppm$. As deionized water and simulated acid rain (pH 3,4) were percolated through columns packed tungsten ore tailing, the amount of Mn, Na, Ca which were dissolved by pH4 solution was higher than those by distilled water. However, W and Mo were eluted easily by high pH solution. The change of heavy metal concentration by column experiment packed zeolite was effective a little because heavy metals were adsorved much more by zeolite.

  • PDF

Seasonal Variation and Natural Attenuation of Trace Elements in the Stream Water Affected by Mine Drainage from the Abandoned Indae Mine Areas (인대광산 지역 광산배수에 영향을 받은 하천에서 미량원소의 계절적인 수질변화와 자연저감)

  • Kang, Min-Ju;Lee, Pyeong-Koo;Choi, Sang-Hoon
    • Economic and Environmental Geology
    • /
    • v.40 no.3 s.184
    • /
    • pp.277-293
    • /
    • 2007
  • Seasonal and spatial variations in the concentrations of trace elements, pH and Eh were found in a creek watershed affected by mine drainage and leachate from several waste rock dumps within the As-Pb-rich Indae mine site. Because of mining activity dating back to about 40 years ago and rupture of the waste rock dumps, this creek was heavily contaminated. Due to the influx of leachate and mine drainage, the water quality of upstream reach in this creek was characterized by largest seasonal and spatial variations in concentrations of Zn(up to $5.830 mg/{\ell}$), Cu(up to $1.333 mg/{\ell}$), Cd(up to $0.031 mg/{\ell}$) and $SO_4^{2-}$(up to $173 mg/{\ell}$), relatively acidic pH values (3.8-5.1) and highly oxidized condition. The most abundant metals in the leachate samples were in order of Zn($0.045-13.909 mg/{\ell}$), Fe($0.017-8.730mg/{\ell}$), Cu($0.010-4.154mg/{\ell}$) and Cd($n.d.-0.077mg/{\ell}$), with low pH(3.1-6.1), and high $SO_4^{2-}$(up to $310 mg/{\ell}$). The mine drainage also contained high concentrations of Zn, Cu, Cd and $SO_4^{2-}$ and remained constantly near-neutral pH values(6.5-7.0) in all the year. While the leachate and mine drainage might not affect short-term fluctuations in flow, it may significantly influence the concentrations of chemicals in the stream. The abundance and chemistry of Fe-(oxy)hydroxide within this creek indicated that the Fe-(oxy)hydroxide formation could be responsible for some removal of trace elements from the creek waters. Spatial and seasonal variations along down-stream reach of this creek were caused largely by the influx of water from uncontaminated tributaries. In addition, the trace metal concentrations in this creek have been decreased nearly down to the background level at a short distance from the discharge points without any artificial treatments after hydrologic mixing in a tributary. The nonconservative(i.e. precipitation, adsorption, oxidation, dissolution etc.) and conservative(hydrologic mixing) reactions constituted an efficient mechanism of natural attenuation which reduces considerably the transference of trace elements to rivers.

Analysis on Contaminant Transport according to the Embedded Depth of Vertical Barrier of Offshore Landfill (해상 폐기물매립지 연직차수벽체 근입심도에 따른 오염물질 이동특성 분석)

  • Park, Haeyong;Oh, Myounghak;Kwon, Osoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.8
    • /
    • pp.29-37
    • /
    • 2016
  • In order to prevent leakage of contaminants in offshore landfill, vertical barrier should be installed. Vertical barrier should be installed at designed depth of seabed to prevent the horizontal transport of contaminant in the subsurface. In this study, the seepage and contaminant transport in the subsurface according to embedded depth of vertical barrier were analyzed by using 2-D finite element analysis program SEEP/W and 3-D finite difference analysis program Visual Modflow. Numerical modelling results show that seepage flux and contaminant transport in seabed was greatly reduced when vertical barrier was installed at certain depth of low permeable layer. Therefore, the determination of minimum embedded depth for preventing contaminant leakage is helpful to design the economical vertical barrier.

Vanadium Leaching Behavior from Domestic Vanadium Bearing Titanomagnetite Ore through CaO Roasting (국내산 함바나듐 티탄자철광으로부터 CaO 배소를 통한 바나듐 침출거동)

  • Shin, Dong Ju;Joo, Sung-Ho;Lee, Dongseok;Jeon, Ho-Seok;Shin, Shun Myung
    • Resources Recycling
    • /
    • v.30 no.4
    • /
    • pp.27-34
    • /
    • 2021
  • In this study, the leaching behavior of vanadium (V) was investigated through CaO roasting and sulfuric acid leaching from domestic V-bearing titanomagnetite (VTM). Changes in the phase according to the amount of CaO added and roasting temperature were analyzed. Regardless of the roasting conditions, perovskite (CaTiO3) was preferred to form. When the CaO content was increased, the calcium ferrite (CaFeOx) phase was formed; otherwise, ferrite (Fe2O3) was preferred. After CaO was roasted, leaching was performed for 6 h with 1M sulfuric acid at 50℃ and a 10% solid-liquid ratio. Results of leaching revealed that when the roasted product was sintered, V was not sufficiently oxidized, and the leaching efficiency decreased. In addition, when the roasting temperature was low, the leaching efficiency of V decreased due to the influence of unreacted excess CaO. To lower the leaching efficiency of iron and titanium in VTM concentrates, suppressing the formation of CaTiO3 and CaFeOx was necessary by minimizing the amount of CaO added. Consequently, a leaching efficiency of 86% V, 4.3% Fe, and 6.5% Ti was obtained when the roasted product of 1150℃ and 10 wt% CaO was leached.

A Study on Contaminant Sorption Capacity of Soil Liner for Seashore Waste Landfill by Using Column Test Apparatus (주상시험장치를 이용한 해안 폐기물 매립장 지반토지 오염물 흡착능에 관한 연구)

  • Jang, Yeon-Su;Han, Seong-Gil;Kim, Su-Sam
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.75-84
    • /
    • 1997
  • In this paper, the retardation capacity of marine clay and weathered soil of seashore waste landfill is analyzed by using a laboratory column apparatus for organic and inorganic components which can represent the components of the leachate of municipal waste landfill. The results show that sorption capacity marine clay for potassium is larger than that of weathered soil. Lead and cadmium are adsorbed completely at concentrations higher than the real concentrations developed in the landfill. The bottom soils of seashore landfill can also retard some nondegradable components of organics although their sorption capacities for organics were less than those for inorganics.

  • PDF