• Title/Summary/Keyword: 진열

Search Result 316, Processing Time 0.029 seconds

Lift-Off Voltage and Partial Discharge Characteristics of Free Conducting Particles in GIS (GIS 내 금속입자의 부상전압과 부분방전특성 연구)

  • Yoon, Jin-Yeol;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1684-1686
    • /
    • 1998
  • Gas Insulated Switchgear(GIS) acts as an indispensible part in power transmission network. In order that GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, using the EHV test chamber, partial discharge quantity in GIS was measured when free conducting particles initiate to discharge for providing fundamental data for the purpose of developing predictive diagnosis technology on site GIS.

  • PDF

A study on the modelling of power transformer winding vibration (변압기 권선진동의 모형화 연구)

  • Lee, Sung-Ho;Kang, Chang-Gu;Kim, Jae-Chul;Chung, Chan-Soo;Kwak, Hee-Ro;Joo, Byung-Soo;Yoon, Jin-Yeol;Chung, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.216-218
    • /
    • 1994
  • This paper established on vibration model of transformer winding caused, mainly, by load current. We considered the rotations between loads and vibration amplitudes by changing load current in constant temperature and voltage, to get the modeling of transformer winding vibration. Equation between loads and vibration signal's amplitudes using LS approximation mode it possible to predict a vibration signal's amplitude at any load. With this equation, we arc willing to establish the basis data for power transformer diagnosis.

  • PDF

Corona Discharge In GIS Initiated by Free Conducting Particles (자유이물에 의한 GIS 내부 코로나특성 연구)

  • Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1801-1803
    • /
    • 1997
  • The Gas Insulated Switchgear(GIS) has made it an indispensible part of power transmission network. In order that the GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, the corona discharge in GIS initiated by the free conducting particles was discribed through laboratorial experiment The magnitude of the corona discharge voltage was measured using current measuring method by the impedance. The purpose of this experiment is to get fundamental data which is essential to develop GIS diagnosis technology.

  • PDF

Winding Deformation Measurement using Low-voltage Impulse Tester in Transformers (변압기에서 저압충격시험기를 이용한 권선변형 측정)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin;Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1737-1739
    • /
    • 1997
  • We describe the characteristic of LVI test system and methods to detect the deformation of windings in the power transformers. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformer. And we discuss the application of LVI test method and the condition of RSG pulse through results of in one and three pole transformers under Lab. tests.

  • PDF

A Surface Aging Characteristics of Silicone Rubber by Boiling in Salt Water (Salt Water Boiling에 의한 Silicone Rubber의 표면열화특성)

  • Han, S.I.;Yu, S.D.;Lee, B.S.;Yoon, J.Y.;Park, K.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1497-1499
    • /
    • 1997
  • This paper dealt with the surface aging characteristics of silicone rubber used as the surface material of outdoor polymer insulators under accelerated aging condition. There are many aging factors in natural environment. In this paper, the silicone rubber were accelerated to evaluate their performance against salt fog, that is, they were dipped in pure water and salt water under boiling condition. Then, contact angle and SEM(Scanning Electron Microscope) were used to estimate surface hydrophobicity, and dielectric loss($tan{\delta}$) and surface leakage current were measured to observe the electrical characteristics.

  • PDF

Research about business model by personal shop (Personal shop에 의한 비즈니스 모델에 관한 연구)

  • 노형진;정한열
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.11a
    • /
    • pp.51-57
    • /
    • 2001
  • Electronic commerce talks that is new economy paradigm to guide 21th century. To corporations are not turned over in new business environment, is situation that is introducing electronic commerce actively. But, model who take advantage of extensity, patency of internet maximum than simple business model that do existing of(-line on-line Tuesday is going to be more suitable model in electronic commerce. This Research is plan with customer more actively in passive operation that desire goods purchase supplying goods information to customer simply and can speak as business model that drive customer participation for display of goods and operation whole of sale.

  • PDF

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

Study on the Laser Salt Meter (활선염해 측정장치 개발연구)

  • Jin, Y.S.;Kim, H.J.;Chung, S.J.;Yoon, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1636-1638
    • /
    • 1994
  • Salt deposited on the surface of insulators used in electric power system causes flash-over accidents. Therefore, the quantity of salt on insulators should be monitored not to exceed a critical value. We propose a new remote sensing technique to measure the quantity of salt on insulators of power systems. A pulsed laser beam is focussed on ah insulator to dissociate the salt to sodium atoms. The amount of the salt is measured from the intensity of the spontaneous mission from the sodium atoms. In this paper, a compact salt meter composed of pulsed Nd:YAG laser and omission signal detection system will be introduced. And measurement condition such as the sensitivity, detection range, required laser fluence will be investigated.

  • PDF

Smart LED lighting system (스마트 LED조명 시스템개발)

  • Kim, Min-Seop;Ryu, Dae-Hyun;Jang, Gyeong-Jun;Na, Kwan-Sik
    • Annual Conference of KIPS
    • /
    • 2017.11a
    • /
    • pp.1127-1129
    • /
    • 2017
  • 상품의 매출은 진열 환경에 크게 영향을 받기 때문에 백화점을 비롯한 각급 매장에서는 다양한 연구를 진행하고 있다. 특히 조명에 따라 의류나 가구는 물론이고 과일을 비롯한 식료품의 매출액도 많은 영향을 받는 것으로 알려져 있다. 이에 따라 어떤 색상의 배경이나 조명이 소비자의 주목을 끌고 호감을 줄 수 있는지에 대한 연구들이 디자인 학자들을 중심으로 이루어지고 있으나, 실제 매장에서는 상품 색상에 맞춰 배경이나 조명을 변경하는 것이 거의 불가능한 실정이다. 따라서 본 연구에서는 상품 색상별로 소비자의 주목을 끌고 호감을 이끌어내서 상품 구매로 이어질 수 있는 IoT 기반의 스마트 LED 조명 시스템을 아두이노 보드를 이용하여 구현하고자 한다.

Analysis on the Current Status of Japanese HAPS Development (일본의 HAPS 개발 동향 분석)

  • Park, J.M.;Ahn, D.S.
    • Electronics and Telecommunications Trends
    • /
    • v.16 no.5 s.71
    • /
    • pp.55-66
    • /
    • 2001
  • 새로운 무선 통신 인프라로 크게 부각되고 있는 HAPS(High Altitude Platform Station) 시스템은 국제 표준화 및 기술 기준을 정립하는 국제전기통신연합(ITU)의 최고 의결회의인 세계전파통신회의(WRC)에서 HAPS용 주파수를 분배함에 따라, 선진국을 중심으로 HAPS 상용화를 위한 연구개발이 활발히 진행중에 있다. 특히, 우리나라와 인접한 일본은 정부의 적극적인 지원과 산/학/연의 효율적인 공조 체제를 바탕으로 HAPS 개발과 관련하여 과히 세계 선두 진열에 들어서 있다고 해도 과언이 아니다. 아직 HAPS 개발에 필요한 기술적, 재정적 기반이 부족한 우리나라로서는 이웃한 일본의 연구개발 동향을 항시 주시하고 정확하게 분석한다면 향후 독자적인 연구개발 수행 시 많은 도움이 될 것이다.