• Title/Summary/Keyword: 종곡선

Search Result 389, Processing Time 0.032 seconds

Axial Pressing Method Using Pulse Magnetizing Field for the Preparation of Nd-Ee-B Sintered Magnets (펄스자장을 이용한 고이방화 Nd-Fe-B자석의 종축자장성형방법)

  • Kim, Dong-Hwan;Kang, Byung-Kil;Jang, Dong-Youl;Kim, Andrew S.;Kim, Sang-Myun;Jang, T.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.182-186
    • /
    • 2003
  • A new axial pressing method using pulse magnetizing field was studied to improve the remanence of Nd-Fe-B sintered magnets. In order to make near-net shape green compacts of butterfly, disk, or coin magnets, conventional axial-type pressing has been normally used. However, compared to the transverse-type pressing, it is not possible to obtain higher remanence by this method because the magnetic alignment of powder begins to deteriorate when the density of green compacts increases over a critical value. On the other hand, we found that an axial pressing under pulse magnetizing field was very effective to increase the degree of magnetic alignment of powder, yielding remanences even higher than those obtained by the transverse pressing. In this study, it was revealed that appropriate tapping density and how to apply pulse magnetic held were important to improve the grain alignment and thus remanence of Nd-Fe-B sintered magnet.

An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement (격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구)

  • Noh, Chi-Hoon;Jang, Nag-Seop;Oh, Hongseob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.73-81
    • /
    • 2022
  • Recently, as the service life of structures increased, the load-carrying capacity of deteriorated reinforced concrete, where corrosion of reinforcing bars occurs due to various causes, is frequently decreased. In order to address this problem, many studies on the bond characteristic of FRP (Fiber Reinforced Polymer) bars with corrosion resistance, light weight and high tensile strength have been conducted, however there are not many studies on the bond characteristic of grid-typed CFRP embedded in concrete. Therefore, in order to evaluate the bond characteristics of grid-typed CFRP and its usability as a substitute for steel rebar, a pull-out test is performed using the longitudinal bond length and transverse grid length of the grid-typed CFRP as variables. Through the pull-out test, the bond load-slip curve of the grid-typed CFRP is derived, and the bond behavior is analyzed. The total bond load equation is proposed as the sum of the bond force of the longitudinal bond length and the shear force of the grid in the transverse direction. Also, expressing the area of the bond load-slip curve as total work, the change in dissipated energy with respect to the slip is analyzed to examine the effect of the tranverse grid on the bond force.

Properties of ultra-thin silicon oxynitride films using plasma-assisted oxynitridation method (플라즈마 처리 기법을 이용한 초박형 실리콘 옥시나이트라이드 박막의 특성)

  • Jung, Sung-Wook;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.260-260
    • /
    • 2009
  • 초박형 절연막은 현재 다양한 전자소자의 제작과 향상을 위하여 활용되고 있으며, 일반적인 화학 기상 증착 방법으로는 균일도를 확보하기 어려운 문제점을 가지고 있다. 본 논문에서는 디스플레이의 구동소자로 활용되는 박막 트랜지스터의 특성 향상과 비휘발성 메모리 소자의 터널링 박막에 응용하기 위하여 초박형 실리콘 옥시나이트라이드 박막의 증착과 이의 특성을 분석하였다. 실리콘 옥시나이트라이드 박막은 실리콘 산화막에 질소가 주입되어 있는 형태로 실리콘 산화막과 실리콘 계면상에 존재하는 질소는 터널링 전류와 결함 형성을 감소시키며, bulk 내에 존재하는 질소는 단일 실리콘 산화막에 비해 더 두꺼운 박막을 커패시턴스의 감소없이 이용할 수 있는 장점이 있다. 플라즈마 처리 기법을 이용하였을 경우에는 초박형의 균일한 박막을 얻을 수 있으며, 본 연구에서는 이산화질소 플라즈마를 이용하여 활성화된 질소 및 산소 라디칼들이 실리콘 계면을 개질하여 초박형 실리콘 옥시나이트라이드 박막을 형성활 수 있다. 플라즈마 처리 시간과 RF power의 변화에 따라 형성된 실리콘 옥시나이트라이드 박막의 두께 및 광학적 특성은 엘립소미터를 통하여 분석하였으며, 전기적인 특성은 금속-절연막-실리콘의 MIS 구조를 형성하여 커패시턴스-전압 곡선과 전류-전압 곡선을 사용하여 평가하였다. 이산화질소 플라즈마 처리 방법을 사용한 실리콘 옥시나이트라이드 박막을 log-log 스케일로 시간과 박막 두께의 함수로 전환해보면 선형적인 증가를 나타내며, 이는 초기적으로 증착률이 높고 시간이 지남에 따라 두께 증가가 포화상태에 도달함을 확인할 수 있다. 실리콘 옥시나이트라이드 박막은 초기적으로 산소의 함유량이 많은 형태의 박막으로 구성되며, 시간의 증가에 따라서 질소의 함유량이 증가하여 굴절률이 높고 더욱 치밀한 형태의 박막이 형성되었으며, 이는 시간의 증가에 따라 플라즈마 챔버 내에 존재하는 활성종들은 실리콘 박막의 개질을 통한 실리콘 옥시나이트라이드 박막의 두께 증가에 기여하기 보다는 형성된 박막의 내부적인 성분 변화에 기여하게 된다. 이산화질소 플라즈마 처리 시간의 변화에 따라 형성된 박막의 정기적인 특성의 경우, 2.3 nm 이상의 실리콘 옥시나이트라이드 박막을 가진 MIS 구조에서 accumulation과 inversion의 특성이 명확하게 나타남을 확인할 수 있다. 아산화질소 플라즈마 처리 시간이 짧은 실리콘 옥시나이트라이드 박막의 경우 전압의 변화에 따라 공핍영역에서의 기울기가 현저히 감소하며 이는 플라즈마에 의한 계면 손상으로 계면결합 전하량이 증가에 기인한 것으로 판단된다. 또한, 전류-전압 곡선을 활용하여 측정한 터널링 메카니즘은 2.3 nm 이하의 두께를 가진 실리콘 옥시나이트라이드 박막은 직접 터널링이 주도하며, 2.7 nm 이상의 두께를 가진 실리콘 옥시나이트라이드 박막은 F-N 터널링이 주도하고 있음을 확인할 수 있다. 즉, 2.5 nm 두께를 경계로 하여 실리콘 옥시나이트라이드 박막의 터널링 메카니즘이 변화함을 확인할 수 있다. 결론적으로 2.3 nm 이상의 두께를 가진 실리콘 옥시나이트라이드 박막에서 전기적인 안정성을 확보할수 있어 박막트랜지스터의 절연막으로 활용이 가능하며 2.5 nm 두께를 경계로 터널링 메커니즘이 변화하는 특성을 이용하여 비휘발성 메모리 소자 제작시 전하 주입 및 기억 유지 특성을 확보를 위한 실리콘 옥시나이트라이드 터널링 박막을 효과적으로 선택하여 활용할 수 있다.

  • PDF

Study on the Moisture Sorption Characteristics of Seasoned Dried Laver (조미 건조김의 흡습특성에 관한 연구)

  • 임종환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.4
    • /
    • pp.476-483
    • /
    • 1993
  • The moisture sorption characteristics of commercially produced seasoned dried layer (Porphyra yezoensis) was investigated by measuring sorption isotherms. The laver and two kinds of desiccant (silica gel and zeolite based desiccant) were used at temperatures of 30, 40 and 5$0^{\circ}C$ respectively using the method of saturated salt solution. Time to reach the equilibrium moisture content at each temperature and relative humidity varied from 4~6hr for the laver to 20~25hr for the silica gel and 43~46hr for the zeolite. The isotherms of the layer and the desiccants showed the characteristic sigmoidal curve. Monomolecular layer moisture content calculated using the BET equation at each temperature (30, 40, 5$0^{\circ}C$) were 5.26, 4.46 and 3.49% (d.b.) for the laver, 17.32, 15.24 and 12.89% (d.b.) for the silica gel, 16.89, 14.92 and 14.44% (d.b.) for the zeolite, respectively, Both desiccants showed higher values of the monomolecular layer moisture content than the laver. In all cases, the monomolerular layer moisture contents were decreased linearly as the temperature was increased in the experimental ranges. Water vapor transmission rate of the packaged material was also influenced by the temperature, which could be explained by the Arrhenius equation.

  • PDF

The Scale-Dependent Dispersion Through Convergent Flow Tracer Tests in Alluvial Aquifer with High Permeability at the Ttaan isle, Gimhae City (김해 딴섬의 고투수성 충적층에서 수렴흐름 추적자시험에 의한 규모종속 수리분산 연구)

  • Kang, Dong-Hwan;Shim, Byoung-Ohan;Kwon, Byung-Hyuk;Kim, Il-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.17-25
    • /
    • 2007
  • Convergent flow tracer test for 2 m (IW-1 well) and 5 m (IW-2 well) of test scale was conducted at the alluvial aquifer with high permeability and storativity. Pumping rate for convergent flow tracer test were $2,500m^3/day$, and the chloride tracer of 5 kg was instantaneously injected into IW-1 and IW-2 wells. Differences of first arrival time and peak concentration were analyzed by using the concentration breakthrough curves of chloride. Recovered chloride mass were analyzed by recovered cumulative mass curves. And, increment and decrement for chloride concentration were analyzed through chloride concentration versus recovered cumulative mass ratio graphs. Also, increment and decrement ratios of chloride concentration were estimated through linear regression analyses for increment and decrement intervals of chloride concentration. Longitudinal dispersivities were estimated by quot;Converging Radial Flow With Instantaneous Injectionquot; method using CATTI code. Longitudinal dispersivities estimated by CATTI code were 0.4152 m between pumping well and IW-1 well, and 3.2665 m between pumping well and IW-2 well. Longitudinal dispersivity was increased according to far distance from the pumping well. The longitudinal dispersivity according to distance were estimated as 0.21 between pumping well and IW-1 well, and 0.65 between pumping well and IW-2 well.

Ventilatory Dynamics in Bronchiectasis (기관지확장증의 환기역학)

  • Kim, Yeon-Jae;Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.548-557
    • /
    • 1993
  • Background: Bronchiectasis is a irreversible disease, a lot of cases of which are associated with chronic bronchitis, pulmonary emphysema and bronchial asthma due to chronic recurrent pulmonary infection. Therefore, pulmonary functions in bronchiectasis may also vary with associated diseases or involved segments. Methods: For the evaluation of ventilatory dynamics in bronchiectasis with respect to the pathoanatomic types of bronchiectasis and the degree of dyspnea, a total of 93 cases comprising 45 cases of tubular, 30 saccular and 18 mixed type of bronchiectasis whose clinical diagnosis was confirmed by bronchography were analyzed retrospectively. They were also divided into two groups: those with Hugh-Jones dyspnea grade 1 & 2 (group I) and those with Hugh-Jones dyspnea grade 3 & 4 (group II). Pulmonary functions tested in this study were analyses of curves of forced expiratory volume and flow-volume, and determinations of maximal voluntary ventilation and closing volumes. Results: The results were as follows; 1) The vital capacity and parameters reflecting expiratory flow rate except PEF were significantly reduced in saccular and mixed type than that in tubular type of bronchiectasis. 2) In saccular and mixed type, the maximal voluntary ventilation tended to decrease while CV/VC tended to increase. 3) As the degree of dyspnea became serious, the involved segments were progressively increased. In contrast, ventilatory functions were significantly reduced in proportion to the severity of dyspnea. Conclusion: These findings suggest that in bronchiectasis, there be obstructive ventilatory impairment combined with mild restrictive ventilatory impairment, which becomes more prominent in saccular and mixed type and also as the degree of dyspnea progresses.

  • PDF

Load-deflection characteristics and plastic deformation of NiTi closed coil springs (수종의 니켈-티타늄 폐쇄형 코일 스프링의 하중-변위 특성 및 소성 변형 비교)

  • Son, Ah-Young;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.310-319
    • /
    • 2009
  • Objective: NiTi closed coil springs were reported to have relatively constant unloading forces. However, the characteristics of NiTi closed coil springs from various manufacturers have not been elucidated. The purpose of this study was to compare load-deflection characteristics of various NiTi closed coil springs and to find out the optimal range of extension. Methods: Seven kinds of NiTi closed coil springs from five manufacturers were tested. Load deflection curves were obtained at extension ranges from 2 mm to 30 mm. Also, springs were kept extended during a 4 week period, and then load deflection curves were obtained again. Results: Sentalloy (Tomy) and Jinsung blue (Jinsung) showed superelasticity in every extension ranges tested and showed plastic deformation of less than 1 mm. Ni-Ti (Ormco) showed superelasticity only after the springs were extended at or more than 10 mm, thereby meaning that clinicians should extend these springs at or more than 10 mm to utilize the superelasticity. Orthonol (RMO) and Nitanium (Ortho Organizers) did not show superelasticity. After 4 weeks of extension, all springs showed plastic deformation less than 1 mm when the extension was at or under 25 mm. Conclusions: The superelastic behavior of NiTi closed springs were different among various NiTi spring products, and some NiTi closed springs failed to show superelasticity.

A study on development of CRM by means of XRF analysis for fine ceramic ($BaTiO_3$) (티탄산바륨 소재의 XRF 분석용 CRM 개발에 관한 연구)

  • Kim, Young Man;Jeong, Chan Yee;Lim, Chang Ho;Song, Taek Yong;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.382-391
    • /
    • 1996
  • In this study, 12 different chemical species of fine ceramic($BaTiO_3$) were synthesized as the standard materials for the fast and accurate measurements of X-ray fluorescence spectrometry. Samples were diluted to sixteen times with the filling compound ($Li_2B_4O_7+LiBO_2$) in order to remove the matrix effect, and to get the convenient storage and homogeneity of ingredients. The matrix effects among the ingredients were corrected by the empirical coefficient method based on the Lucas-Tooth and Price model. The standard curve on 12 standard materials containing 15 elements were obtained by using X-ray fluorescence spectrometry at three different laboratories. The correlation factors of BaO, PbO, SrO, $Fe_2O_3$, $La_2O_3$, $SnO_2$, ZnO, $ZrO_2$, CaO indicated the relati vely good agreement over 0.995 among the three different laboratories. $SiO_2$ and $Al_2O_3$ showed the poor linearity because of their low fluorescence intensities.

  • PDF

The Practice of Bending Deflection using Non-destructive MOE of Glulam (비파괴 탄성계수를 이용한 집성재의 휨변형 예측)

  • Park, Jun-Chul;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.48-55
    • /
    • 2009
  • In the glulam beam deflection it is necessary to check the reliability of theory formula, because of wood anisotropy and wood qualities (knot, slop of grain). In this experiment, when bending stress occurred on glulam, practice deflection of glulam measuring with AICON DPA-Pro 3D system were compared with prediction deflection calculated as substituting MOE through non-destructive testing and static MOE through bending test in differential equation of deflection curve. MOE using ultrasonic wave tester of laminae, MOE using natural frequencies of longitudinal vibrations ($E_{cu}$, $E_{cf}$), MOE using ultrasonic wave tester of glulam ($E_{gu}$) and MOE using natural frequencies of longitudinal vibrations ($E_{gf}$) were substituted in this experiment. When practice deflection measured by 3D system was compared with prediction deflection calculated with differential equation of deflection curve, within proportional limit the ratio of practice deflection and prediction deflection was similar as 1.12 and 1.14, respectively. Deflection using ultrasonic wave tester was 0.89 and 0.95, Deflection using natural frequencies of longitudinal vibrations was 1.07 and 1.10. The results showed that prediction deflection calculated by substituting using non-destructive MOE of glulam having anisotropy in differential equation of deflection curve was agreed well with practice deflection.

Speciation Analysis of Arsenic Species in Surface Water (수중의 비소 종 분리 분석)

  • Jeong, Gwan-Jo;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.621-627
    • /
    • 2008
  • In this study, a technique of speciation and determination of the trace inorganic arsenic(As(III) and As(V)) in water sample using HPLC-DRC-ICP-MS has been developed. Isocratic mobile phase of 10 mM ammonium nitrate and 10 mM ammonium phosphate monobasic was used and methanol(5 v/v%) was used as flushing solvent. Selection of the best flow rate of reaction gas, O$_2$, and optimization of the parameters such as pH and flow rate of mobile phase, and injection volume of sample for the separation and detection of arsenic species were carried out. The oxygen flow rate of 0.5 mL/min, pH of 9.4 and flow rate of 1.5 mL/min of mobile phase, and injection volume of sample of 100 $\mu$L were found to be the best parameters for the speciation and determination of arsenic species. The analytical features of the method were detection limit 0.10 and 0.08 $\mu$g/L, precision(RSD) 4.3% and 3.6%, and recovery 95.2% and 96.4% for As(III) and As(V), respectively. Analysis time was 4 minutes per sample. Linear calibration graphs with r$^2$ = 0.998 were obtained for both As(III) and As(V). Speciation analysis of arsenic species in the raw water samples collected from the tributary streams to Han River and main stream of Paldnag were performed by the proposed method. The concentrations of As(III) ranged from 0.10 to 0.22 $\mu$g/L and As(V) concentrations ranged from 0.44 to 1.19 $\mu$g/L, and 93.5% of total arsenic was found to be As(V).