• Title/Summary/Keyword: 정수처리공정

Search Result 294, Processing Time 0.037 seconds

Degradation of Sulfonamide Antibiotic Substances by Ozonation: An Experimental and Computational Approach (설폰아미드계 항생물질의 오존산화분해에 대한 계산화학적 해석 및 실험적 검증)

  • Won, Jung Sik;Lim, Dong Hee;Seo, Gyu Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.442-450
    • /
    • 2014
  • Concern has grown over a presence of micropollutants in natural water since sulfonamide antibiotic substances such as sulfamethazine, sulfamethoxazole, sulfathiazole have been frequently detected in Nakdong River, Korea. The current work investigates the degradation of the three sulfonamide substances by using quantum chemistry calculations of density functional theory (DFT) and experimental measurement techniques of Fourier transform infrared spectroscopy (FT-IR) and ultraviolet-visible spectrophotometer (UV-VIS). DFT calculations demonstrate that the lowest energy gap between the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbitals (LUMO) lies in sulfanilamide functional group of sulfonamide, implying that the sulfanilamide functional group would be the most active site for ozone oxidation. Also, UV-VIS spectra and FT-IR analysis reveal that 260 nm band originated from sulfanilamide group was absent after ozone oxidation, indicating that a functional group of amine (N-H) was removed from sulfanilamide. Both theoretical and experimental observations agree well with each other, demonstrating the DFT calculation tool can be an alternative tool for the prediction of chemical reactions in purification treatment processes.

The effect of urban conditions, external influences, and O&M efficiency on urban water system from the perspective of water-energy nexus (도시 여건, 외부 영향 및 운영관리 효율이 넥서스 관점에서 도시 물순환 시스템에 미치는 영향)

  • Choi, Seo Hyung;Shin, Bongwoo;Shin, Eunher
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.31-31
    • /
    • 2022
  • 기후변화, 물 부족, 인구 증가와 도시화로 인한 물 수요 증가, 수질 악화, 노후화된 인프라와 같은 세계적인 물문제의 증가로 인해, 도시 물순환 시스템 관리는 더 큰 어려움을 겪고 있다. 취수, 도·송수, 정수처리, 배·급수, 용수 사용, 하수 집수, 하수 처리, 재이용 및 배출 과정을 포함하는 도시 물순환 시스템의 과정은 매우 에너지 집약적인 활동이며, 이와 같은 에너지 소비는 탄소 배출과 양의 직접적인 상관관계가 있다. 따라서 자원 관리 및 데이터 관리를 최적화하기 위해 넥서스 관점의 접근법이 도시 물순환 시스템에 점차적으로 도입되고 있는 추세이다. 도시 물순환 시스템 넥서스에서는 일반적으로 에너지 인텐시티로 표현되는 물을 위한 에너지를 이해하는 것이 중요하다. 에너지 인텐시티의 차이는 기후(연평균 강수량, 단기 기후 변동성, 기후패턴 등), 지리적 특징(표고차, 평지비, 위치 등), 시스템 특성(총급수량, 인구, 인구밀도, 관로 연장 등) 및 운영관리 효율(수압, 누수율, 에너지 효율 등)과 밀접한 관계가 있다. 그리고 도시 물순환 시스템에서 에너지 관리를 증진시킨 방안은 유지관리 효율 개선(물·에너지 관리전략, 물손실 관리, 수요 관리 및 수요 대응 등), 신기술 도입, 그리고 에너지 회수로 나누어진다. 본 연구에서는 기존 문헌의 자료를 분석하여 도시 물순환 시스템의 각 공정별 에너지 인텐시티를 분석하였으며, 시스템 다이나믹스를 적용하여 다양한 도시 여건(인구, lpcd, 누수율, 취수원, 에너지 인텐시티)에서 외부영향(기후변화, 도시화)과 운영효율 변동(운영효율 향상, 신시술 도입)에 따른 도시 물순환 시스템 내 자원 사용 및 이동을 분석하였다. 에너지 인텐시티는 전체 도시 물순환 시스템, 상수 시스템, 하수시스템에서 각각 2.334 kWh/m3, 1.029 kWh/m3, 1.024 kWh/m3를 나타내었으며, 용수사용, 담수화, 재이용 과정에서는 매우 높은 값이 나타났다. 에너지 인틴시티의 값은 외부 영향에 크게 좌우되는 것으로 분석되었으며, 운영효율의 변동에 따라서 물 및 에너지 사용량은 변화하였지만 에너지 인텐시티의 변동은 크지 않았다. 이에 따라 도시 물순환 시스템을 넥서스 관점에서 관리하기 위해서는 에너지 인텐시티 이외에 물 및 에너지 사용량, 유수수량 관점 에너지 인텐시티, 사용수량 관점 에너지 인텐시티를 종합적으로 고려하는 것이 필요하다.

  • PDF

Computing the Dosage and Analysing the Effect of Optimal Rechlorination for Adequate Residual Chlorine in Water Distribution System (배.급수관망의 잔류염소 확보를 위한 적정 재염소 주입량 산정 및 효과분석)

  • Kim, Do-Hwan;Lee, Doo-Jin;Kim, Kyoung-Pil;Bae, Chul-Ho;Joo, Hye-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.916-927
    • /
    • 2010
  • In general water treatment process, the disinfection process by chlorine is used to prevent water borne disease and microbial regrowth in water distribution system. Because chlorines were reacted with organic matter, carcinogens such as disinfection by-products (DBPs) were produced in drinking water. Therefore, a suitable injection of chlorine is need to decrease DBPs. Rechlorination in water pipelines or reservoirs are recently increased to secure the residual chlorine in the end of water pipelines. EPANET 2.0 developed by the U.S. Environmental Protection Agency (EPA) is used to compute the optimal chlorine injection in water treatment plant and to predict the dosage of rechlorination into water distribution system. The bulk decay constant ($k_{bulk}$) was drawn by bottle test and the wall decay constant ($k_{wall}$) was derived from using systermatic analysis method for water quality modeling in target region. In order to predict water quality based on hydraulic analysis model, residual chlorine concentration was forecasted in water distribution system. The formation of DBPs such as trihalomethanes (THMs) was verified with chlorine dosage in lab-scale test. The bulk decay constant ($k_{bulk}$) was rapidly decreased with increasing temperature in the early time. In the case of 25 degrees celsius, the bulk decay constant ($k_{bulk}$) decreased over half after 25 hours later. In this study, there were able to calculate about optimal rechlorine dosage and select on profitable sites in the network map.

Comparison of Biological Responses and Heat Shock Protein 70 Expression in Chironomidae by Exposure UV and O3 (UV와 O3 노출에 따른 깔따구류의 생물학적 반응 및 열충격 단백질 70 발현)

  • Ji-Hoon Kim;Won-Seok Kim;Jae-Won Park;Bong-Soon Ko;Kiyun Park;Ihn-Sil Kwak
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.4
    • /
    • pp.430-439
    • /
    • 2023
  • UV and O3 are materials used in the water treatment process, and many studies have been reported to remove organic matters, contaminants, and microorganisms. In this study, we were investigated effects of Chirnomidae (Chironomus flaviplumus, Chironomus riparius), which are contamination indicator species to exposure UV and O3 for the survival rate, body color change and gene expression response. The survival rate of C. flaviplumus exposed to UV decreased to about 70% after 24 hours, and C. riparius about 50%. There was no change in the survival rate of C. flaviplumus exposed to O3, and C. riparius decreased to 95% after 10 minutes of exposure, but there was no change during the subsequent exposure time. In addition, UV and O3 exposure to the two species in body color faded in a time-dependent. In the HSP70 gene expression, C. riparius showed an increase in expression after UV exposure compared to the control group, and a significant difference was shown 12 hours after exposure (P<0.05). C. flaviplumus exposed to O3 showed a relatively low expression compared to the control group, and showed a significant difference at 10 minutes and 1 hour after exposure (P<0.05). These results reported the ecotoxicological effects on Chironomidae according to UV and O3 exposure. Therefore, the results of this study can be used as basic data to understand the effects of UV and O3, which are disinfectants used in water treatment plants, on Chirnomidae entering plants.

Application of Enhanced Coagulation for Nakdong River Water Using Aluminium and Ferric Salt Coagulants (낙동강 원수를 대상으로 Al염계 및 Fe염계 응집제를 이용한 고도응집의 적용)

  • Moon, Sin-Deok;Son, Hee-Jong;Yeom, Hoon-Sik;Choi, Jin-Taek;Jung, Chul-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.590-596
    • /
    • 2012
  • Enhanced coagulation is best available technologies to treat NOM in water to produce clean drinking water. In this research, the comparison experiments between conventional coagulation (CC) and enhanced coagulation (EC) using 4 type coagulants i.e., ferric chloride, aluminium sulphate (alum), poly aluminium sulphate organic magnesium (PSOM) and poly aluminium chloride (PACl) were performed in terms of surrogate parameters such as dissolved organic carbon (DOC), trihalomethane formation potential (THMFP), haloacetic acid formation potential (HAAFP) and zeta potential variation in order to find out the most effective coagulant and conditions to fit Nakdong River water. When applied to EC process, the turbidity removal efficiency did not increased gradually compared to the CC process when adding coagulants. Furthermore, the removal efficiency of turbidity became decreased much more as coagulants were added increasingly whereas the removal efficiency of DOC, THMFP and HAAFP became increased by 13~18%, 9~18% and 9~18% respectively compared to the CC process. The characteristics of turbidity removal showed relatively high removal efficiency considering the pH variation in entire pH range when using $FeCl_3$ and PACl. Additionally, in case of alum and PSOM steady removal efficiency was shown between pH 5 and pH 8. In terms of DOC surrogate the coagulants including 4 type coagulants indicated high removal efficiency between pH 5 and pH 7. The removal efficiency of dissolved organic matter (DOM) in EC between less than 1 kDa and more than 10 kDa augmented by 11~21% and 16% respectively compared to the CC process. The removal efficiency of hydrophobic and hydrophilic organic matter proved to be increased by 27~38% and 11~15% respectively. In conclusion, the most effective coagulant relating to EC for Nakdong River water was proved to be $FeCl_3$ followed by PSOM, PAC and alum in order.

Characteristics of Flue Gas Using Direct Combustion of VOC and Ammonia (휘발성 유기 화합물 및 암모니아 직접 연소를 통한 배기가스 특성)

  • Kim, JongSu;Choi, SeukCheun;Jeong, SooHwa;Mock, ChinSung;Kim, DooBoem
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • The semiconductor process currently emits various by-products and unused gases. Emissions containing pollutants are generally classified into categories such as organic, acid, alkali, thermal, and cabinet exhaust. They are discharged after treatment in an atmospheric prevention facility suitable for each exhaust type. The main components of organic exhaust are volatile organic compounds (VOC), which is a generic term for oxygen-containing hydrocarbons, sulfur-containing hydrocarbons, and volatile hydrocarbons, while the main components of alkali exhaust include ammonia and tetramethylammonium hydroxide. The purpose of this study was to determine the combustion characteristics and analyze the NOX reduction rate by maintaining a direct combustion and temperature to process organic and alkaline exhaust gases simultaneously. Acetone, isopropyl alcohol (IPA), and propylene glycol methyl ether acetate (PGMEA) were used as VOCs and ammonia was used as an alkali exhaust material. Independent and VOC-ammonia mixture combustion tests were conducted for each material. The combustion tests for the VOCs confirmed that complete combustion occurred at an equivalence ratio of 1.4. In the ammonia combustion test, the NOX concentration decreased at a lower equivalence ratio. In the co-combustion of VOC and ammonia, NO was dominant in the NOX emission while NO2 was detected at approximately 10 ppm. Overall, the concentration of nitrogen oxide decreased due to the activation of the oxidation reaction as the reaction temperature increased. On the other hand, the concentration of carbon dioxide increased. Flameless combustion with an electric heat source achieved successful combustion of VOC and ammonia. This technology is expected to have advantages in cost and compactness compared to existing organic and alkaline treatment systems applied separately.

Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring (막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.248-254
    • /
    • 2017
  • In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of $3{\mu}m$ or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT).

Development of Multiple Regression Models for the Prediction of Daily Ammonia Nitrogen Concentrations (일별 암모니아성 질소(NH3-N)농도 예측을 위한 다중회귀모형 개발)

  • Chug, Se-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1047-1058
    • /
    • 2003
  • Seasonal occurrence of high ammonia nitrogen(NH3-N) concentrations has hampered chemical treatment processes of a water plant that intakes water at Buyeo site of Geum river. Thus it is often needed to quantify the effect of Daecheong Dam ouflow on the mitigation of $NH_3$-N contamination. In this study, multiple regression models were developed for forecasting daily $NH_3$-N concentrations using 8 years of water quality and dam outflow data, and verified with another 2 years of data set. During model development, the coefficients of determination($R^2$) and model efficiency($E_{m}$) were greater than 0.95. The verification results were also satisfactory although those statistical indices were slightly reduced to 0.84∼0.94 and 0.77∼0.93, respectively. The validated model was applied to assess the effect of different amounts of dam outflow on the reduction of $NH_3$-N concentrations in 2002. The NH3-N concentrations dropped by 0.332∼0.583 mg/L on average during January∼March as outflow increases from 5 to 50cms, and was most significant on February. The results of this research show that the multiple regression approach has potential for efficient cause and effect analysis between dam outflow and downstream water quality.

Comparative Analysis of Microcystin during Water Treatment Process between Real-Time PCR and LC/MS (Real-Time PCR법과 LC/MS법을 이용한 수계중의 마이크로시스틴 검출방법 비교연구)

  • Park, Hong-Gi;Jung, Mi-Eun;Cha, Dong-Jin;Jung, Eun-Young;Bean, Jae-Hoon
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1201-1206
    • /
    • 2010
  • We performed a comparative analysis using a Real-time PCR (Polymerase Chain Reaction) and LC/MS (Liquid-Chromatograph/Mass Spectrometer) method in order to detect microcystin in environmental sources. Among the three different primer sets tested for microcystin using three positive strains of Microcystis aeruginosa by Real-time PCR assay, only TOX2P/TOX2M primer pairs were able to detect Microcystis aeruginosa. According to the results of a survey carried out from June 2009 to September 2009, 11 out of 11 (100%) raw water samples were were found to have microcystin when the Real-Time PCR and LC/MS method was used, with total microcystin concentration ranging from 5.98~219.0 ${\mu}g/l$. A microcystin removal treatment process was used to ensure entire removal, by passing it through a BAC filtration step. It was concluded that real-time PCR assay can be used to estimate micrucystin detection more rapidly and easily than the LC/MS method.

Analysis of Trace Levels of Lodinated Trihalomethanes in Water Using Headspace - GC/ECD (Headspace - GC/ECD를 이용한 수중의 미량 요오드계 트리할로메탄류 분석)

  • Son, Hee-Jong;Song, Mi-Jung;Kim, Kyung-A;Yoom, Hoon-Sik;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Trihalomethanes (THMs) are formed as a results of the reaction of residual chlorine, used as a disinfectant in drinking water, with the organic matter in raw water. Although chlorinated and brominated THMs are the most common disinfection byproducts (DBPs) reported, iodinated THMs (I-THMs) can be formed when iodide is present in raw water. I-THMs have been usually associated with several medicinal or pharmaceutical taste and odor problems and is a potential health concern since they have been reported to be more toxic than their brominated and chlorinated analogs. Currently, there is no published standard analytical method for I-THMs in water. An automated headspace-gas chromatography/electron capture detector (GC/ECD) technique was developed for routine analysis of 10 THMs including 6 I-THMs in water samples. The optimization of the method is discussed. The limits of detection (LOD) and limits of quantification (LOQ) range from 12 ng/L to 56 ng/L and from 38 ng/L to 178 ng/L for 10 THMs, respectively. Matrix effects in river water, sea water and wastewater treatment plant (WWTP) final effluent water were investigated and it was shown that the method is suitable for the analysis of trace levels of I-THMs, in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive.