• Title/Summary/Keyword: 전류계

Search Result 639, Processing Time 0.028 seconds

Effect of the Cross Magnetizatin Saturated Generators on the Analysis of Steady State Stability (정태안정도 해석에 미치는 발전기 교차자화 포화특성의 영향)

  • 김덕영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.115-120
    • /
    • 1998
  • This paper presents a modeling of a synchronous machine infinite bus system of which not only seperated saturation effect but also cross magnetization effect of the saturated generator is included for the more precise analysis of the system. In the process of reforming the flux linkage equations of the state equations which have generator saturation effects, the d-axis coordinated system of a generator is fixed that the d-axis proceeds the q-axis in $90^{\circ}$ to accord with the generally accepted generator model used before. The simulation results show that cross magnetization has a very important effect to the more precise eigenvalue analysis of steady state stability.bility.

  • PDF

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

The Control of Single-Phase Active Power Filter Using Modified Synchronous Reference Frame Method (수정된 동기좌표계를 이용한 단상능동전력필터 제어)

  • Hso, Jin-Seok;Kim, Young-Seok;Kim, Young-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.281-284
    • /
    • 2003
  • 본 논문에서는 비선형 단상부하에 의해 발생하는 전류 고조파를 보상하기 위한 단상능동전력필터의 제어방법을 제안한다. 정규의 단상에 시간지연을 주어 가상의 두 번째 상을 만들어 단상시스템을 두 축을 갖는 직교 좌표로 변환시킬 수 있다. 두 개의 상은 3상 2상 변환에서 사용하는 것과 같이 직교 좌표 시스템을 만들 수 있다. 이 것은 순시 무효전력을 계산하는 방법인 복소계산을 가능하게 한다. 고정 좌표계에서 순시무효전력이론을 적용한 기존의 방법 대신, 본 논문에서는 수정된 동기 좌표계를 이용하여 정상분과 역상분을 계산하여 보상전류 지령치를 결정하였다. 제안된 방법은 고조파저감과 PF개선에 있어 우수한 성능을 보여준다. 시뮬레이션 패키지(PSIM)를 사용하여 모의실험을 하였으며, 제안된 방법의 유효성을 입증하였다.

  • PDF

영광 3 호기 부분충수운전중 정지냉각펌프 안전성 평가

  • 류용호;김세원;유병철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.315-320
    • /
    • 1996
  • 영광 3호기의 정지냉각펌프 성능감시 설비로는 펌프 유량계, 입구압, 출구압, 모터전류 등이 있으며 현장에서 펌프의 소음 감시나 진동 측정 등을 통하여 펌프 건전성을 확인할 수 있다. 부분충수운전중 여러 연구결과 제시된 펌프의 이상징후 증상은 펌프의 소음 증가, 유량계 또는 모터전류의 불규칙 요동이 있으나 정량적인 값을 제시하지 못하고 있으며 공기유입량에 대한 운전제한 근거만 정량적으로 제시되고 있다. 즉, WCAP-l1916에 따른 펌프의 손상 판단 근거는 연속적인 공기 흡입의 경우 2%이내, 간헐적인 공기흡입의 경우 5%를 제시하고 있다. 영광 3 호기의 부분충수운전시 펌프 입구압력을 제외한 다른 펌프 성능감시 변수들은 허용오차 이내로 별다른 펌프 이상 징후를 발견하지 못하였다. 그러나 펌프 입구압력 기록계의 입구압력 및 진동폭 변화는 정지냉각유량률, RCS 수위, 증기발생기 노즐댐 설치 유무에 따라 민감한 변화를 보여주었으며, 펌프의 건전성 감시에 가장 효과적인 변수임을 보여주었다.

  • PDF

Effects of Non-Invasive Constant Microcurrent Stimulation on Expression of BMP-4 After Tibia Fracture in Rabbits (비침습식 미세전류자극이 토끼 경골의 골절 후 BMP-4 발현에 미치는 영향)

  • Cho, mi-suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1124-1129
    • /
    • 2009
  • This study aims to examine the effects of non-invasive constant microcurrent stimulation on expression of Bone Morphogenetic Protein(BMP) 4 after tibia fracture in rabbits. Twenty four rabbits with tibia fracture were randomly divided into control and experimental groups. Each group was divided into four subgroups, based on the duration of the experiment (3, 7, 14, 28 days). The experimental groups received a constant microcurrent stimulation of $20{\sim}25{\mu}A$ intensity with surface Ag-AgCl electrode (diameter 1cm, Biopac, U.S.A.) for 24 hours a day. Cathode of the microcurrent stimulator located on the tibia directly, anode of it did on the gastrocnemius muscle. Rabbits were sacrificed on each of the postoperative days 3, 7, 14, 28. To investigate how non- invasive constant microcurrent stimulation affects bone healing, immunohistochemical analysis of BMP-4 was performed at each point. After evaluation, the test results are as follows: Comparisons of immunohistochemical observation of BMP-4 in 7 days after tibial fracture show that there was shown to be a moderate positive reaction (++) on concentric circles of Harversian system andt he interstitial lamella in the control group, while there was a very strong positive reaction (++++) on concentric circles of Harversian system and interstitial lamellain the experimental group. These results suggest that applying non-invasive constant microcurrent stimulation on fractured bone is helpful to bone healing.

  • PDF

A CFD Modeling of Heat Generation and Charge-Discharge Behavior of a Li-ion Secondary Battery (Li-ion 이차전지의 충방전 시 발열 및 충방전 특성의 CFD 모델링)

  • Kang, Hyeji;Park, Hongbeom;Han, Kyoungho;Yoon, Do Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.114-121
    • /
    • 2016
  • This study investigates a CFD modeling of the charge-discharge behavior due to heat generation during charge-discharge cycles of a Li-ion secondary battery(LIB). Present LIB system adopted a current-density equation, heat and mass transfer governing equations upon the 1-dimensional system to the thickness direction for the rectangular pouch configuration. According to the 3-kinds of the charge-discharge current densities of 1C($17.5A/m^2$), 3C($52.5A/m^2$) and 5C($87.5A/m^2$) subject to a 3 V of cut-off voltage, a constant-temperature system at 298 K and three different heat generating systems were analyzed with comparison. Battery capacity decreases with increment of charge-discharge densities not only at the constant-temperature system but also at the heat-generating system. The time for charge-discharge cycles increases at the heat-generating system compare to the constant-temperature system. These trends are considered that the increase of temperature due to heat generation causes the decrement of equilibrium potential of electrodes and the increment of diffusivity of Li ions. Furthermore, cooling effects were discussed in order to control the influence of heat generation due to charge-discharge behavior of a Li-ion secondary battery.

A Study on the Electrical fire Analysis in Overcurrent of Low Voltage Wiring (저압 배선선로의 과전류 사고시 전기화재분석에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.142-148
    • /
    • 2004
  • Recently, with the growth of software for electromagnetic-thermal analysis, it has been studied that the precise analysis and investigation for cause of the electrical fire using computer simulation is on the basis of theroy for electromagnetic-thermal analysis. But it is very lacking for the precise analysis and investigation of cause for the electrical fire. In this paper, we have simulated the temperature distribution of wire to current and the force between the two conductors according to the current and the distance of the vinyl flat-type electrical wire(600 V, VFF, $2C{\times}$1.25mm^2) using the finite element method(Flux2D) in a overcurrent. And we will present the cause analysis method of electrical fire by experiment for distance between the two conductors according to current and time using large current supply device(Model: EHT_EFAD, Korea) in a overcurrent.

Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types (부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.364-369
    • /
    • 2019
  • The ratios of compliant branch circuit of leakage current and insulation resistance were 68.4% and 90.8%, respectively at the lamp load, 64.6% and 96.5% at the heat load, 86.7% and 88.9% at the power load. Limit of residual current of the zero phase secondary current value at the zero phase primary current was 100 A when rated primary current 400 A more than. The reason why the ratio of branch circuit of the leakage current was less than the ratio of compliant branch circuit of the insulation resistance might be that the leakage current includes the capacitive leakage current and the zero phase current.

Study on the R, L parameter estimation for the high performance current control of the step motor (스텝모터의 고성능 전류제어를 위한 R, L파라미터 추정에 관한 연구)

  • Kwon, Hyuk-Ju;Kim, Hyun Geun;Jin, Sung Min;Kim, Jun Seok
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.531-532
    • /
    • 2016
  • 본 논문에서는 스텝모터의 고성능 전류제어를 위한 모터의 고정자 저항 및 인덕턴스를 Off-Line추정하는 기법에 대해 기술한다. 모터의 고정자 저항 및 인덕턴스를 추정하기 위해 역기전력이 나타나지 않는 주파수영역에서 AC전압을 인가하고 이때의 전류를 측정한다. 또한, 가상 dq좌표계를 도입하여 정지좌표계상의 저역통과필터를 통해 위상지연 없이 전류신호에 포함된 노이즈를 제거하였으며, DC형태의 전류에 대한 분석을 통하여 정확한 모터의 제정수를 계량하는 기법을 적용하였다.

  • PDF

An Analysis of EMI Characteristics and the Induced Load Current on th Transmission Line Being Close to the Rectangular Horn Antenna (구형 혼안테나에 인접된 전송선로에 유기되는 부하전류 및 EMI 특성 해석)

  • 양두영;채관수;이상설
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.4
    • /
    • pp.335-341
    • /
    • 1991
  • We derive the radiation field equation at the naar field region to analyse EMI by the rectangular horn antenna. The EMI loadk current calculated from the load current induced on the transmission line being close to the rectangular horn antenna using the field theory and the transmission line theory. We find the conditions minimizing the EMI from the load current transfer function of distance, frequency and impedances at sending and receiving end. The smaller sending end impedance, the larger EMI load current and the larger sending impedance, the smaller EMI load current.

  • PDF