Development of Automatic Meter Reading and Meter Data Management System for Advanced Metering Infrastructure (첨단계랑인프라를 위한 원격검침 및 계량데이터관리 시스템 개발)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.829-836
    • /
    • 2017
  • This paper is a study on development of a new structured AMR/AMI(automatic meter reading/advance metering infrastructure) system. The developed system has a faster reading and is cheaper and easier to install compared to the existing AMR/AMI system. The system can be applied to AMR/AMI for five kinds of meters, electricity, gas, water, hot-water and calorie meter, which are used in most Korean households. Test results show that the developed system is both economical and reliable both in theoretical and practical applications. The resuts also show that the developed system is more suitable than existing system for AMR/AMI applications.

Development of Automatic Control System for Midnight Electric Ondol (축열식 전기온돌 공급시간자동제어시스템)

  • Park, S.;Jung, B.;Yu, S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.369-371
    • /
    • 2002
  • 기저부하조성 및 부하율 망상을 위한 심야 전력요금제도의 정착으로 최근 심야전력축열기기의 보급이 활성화되고 있다. 그러나 모든 심야전력축열기기들이 심야요금개시시간대인 22:00경에 동시에 가동됨에 따라 23:00경에 심야전력 부하가 최대에 이르러 전력피크가 발생하여 한전의 수요관리에 어려움을 주고 있다. 따라서 이 피크 부하를 심야전력 공급시간대의 저부하 시간대로 분산시킬 수 있는 심야전력기기 공급시간제어장치가 필요하게 되었으며, 이미 축열식전기보일러와 축열식 전기온수기에는 개발 보급되고 있는 실정이다. 이 논문에서는 다른 심야전력축열기기와는 달리 자연방열의 바닥축열난방방식인 축열식전기온돌의 공급시간자동제어장치 알고리즘을 실증실험을 통해서 검증하였다.

  • PDF

안전보건명인 인터뷰 - 근로자의 건강과 안전은 기업 경영의 원동력, (주)경동나비엔 송탄공장 최종숙 주임

  • Kim, Seong-Dae
    • The Safety technology
    • /
    • no.188
    • /
    • pp.22-23
    • /
    • 2013
  • (주)경동나비엔은 1978년 3월에 설립된 우리나라의 대표적인 보일러 생산 업체로 1979년 송탄공장에서 국내 최초 콤팩트형 사각 기름보일러 '코로나 KDB-202'를 출시하면서 업계의 주목을 받기 시작했다. 또한 최근에는 북경, 상해, 미국 등으로 진출하며 명실 공히 글로벌 기업으로 비상하고 있다. 이 같은 화려한 회사소개를 차치하고서라도 (주)경동나비엔을 모르는 사람이 없을 것이다. (주)경동나비엔은 옛 사명인 '경동보일러'로 1990년대 초 중반 '아버님 댁에 보일러 놔드려야겠어요'라는 광고를 통해 대대적으로 브랜드를 알렸기 때문이다. 이후 2006년에는 경동나비엔으로 사명을 변경하고 온수기 난방, 냉방 공조, 홈네트워크 각방제어시스템으로 사업 영역을 확장하고, 콘덴싱 기술력으로 해외 1억 달러의 수출액을 달성하는 등 국내 보일러 업계의 선두를 유지하고 있다. 이러한 (주)경동나비엔은 사업장의 안전관리에 있어서도 남다른 두각을 드러내고 있다. 대규모 기계공장을 운영하고 있는 만큼 이에 대한 안전관리 기술과 노하우도 남다른 것이다. 이번호에서는 (주)경동나비엔의 안전보건을 책임지고 있는 최종숙 주임을 만나 구체적인 업무내용과 안전에 대한 소견을 들어본다.

  • PDF

Sun-Tracking System Using Vision Sensor (비젼 시스템을 이용한 태양광 조명 장치)

  • Kim, In-Uk;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2135-2137
    • /
    • 2001
  • 지구에 공급되는 태양열은 지구상의 모든 인간이 필요로 하는 총 에너지량의 10,000배 이상으로 매우 풍부할 뿐만 아니라 무공해 에너지원으로 매우 좋은 조건을 갖추고 있는데 비해 실제 이용은 태양광 발전장치와 온수 난방에 한정되어 있다. 특히 우리나라는 일사량이 풍부하고 인구밀집 거주지역이 많아 태양에너지 이용이 적절한 것으로 분석된 바 있으며, 환경오염문제가 심각하게 대두되고 있는 상황에서 에너지와 환경문제를 동시에 해결할 수 있는 태양 에너지에 대한 기술개발 및 보급이 반드시 필요하다고 판단된다. 본 연구는 태양광을 집광하여 건물 내에 분배하는 장치를 개발하여 건물 전체 전기에너지 소비량의 약1/3을 차지하고 있는 조명용 전기에너지를 절약함으로써 에너지 절약은 물론 환경오염을 줄이는데 그 목적을 두고 있다.

  • PDF

Heat.Power Control System of Cogeneration using LabVIEW (LabVIEW를 이용한 열병합 발전의 열.전기 제어 시스템)

  • Lee, Song-Keun;Kim, Il-Ju;Lee, Kyu-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.93-98
    • /
    • 2009
  • Cogeneration means the highly energy-efficient generation system that improves energy ratio by generating electricity and heat, and it really affects the improvement of overall efficiency by using industrial process, district heating, and hot-water supply etc. after the energy produced through supplying power to system collects. This thesis indicates the screen of cogeneration flow in LabVIEW and the heat power control system that can be in long-distance control of a district energy system using TCP/IP. We simulated on four computers so that the heat power control system proves long-distance control possible.

Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House (컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Development of an Integrated Meter Reading Home Concentrate Device (통합 원격검침 지시장치 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • This paper highlights the home concentrate device(HCD) that integrates the data reading and display of the six types of meters (water, hot water, heating, cooling, gas and electricity) used in Korean residential areas. Unlike the conventional system which utilizes single MCU, the developed system uses two MCUs for one MCU to gather the meter readings and for the other MCU to communicate to the server computer. Hard ware design, communication protocols, LCD design and program structures are discussed and the test results are shown in this paper. With the implementation of integrated meter reading, the developed system can increase the popularity of automatic meter reading(AMR) with its better scalability, pricing, installation fee, maintenance and faster response.

Characteristic of Thermal Output of Thermally Activated Building System During the Heating Operation According to FDM Analysis (FDM 해석에 의한 구체축열시스템(TABS)의 난방운전시 방열 특성 분석)

  • Lim, Jae-Han;Song, Jin-Hee;Koo, Bo-Kyoung;Song, Seung-Yeong;Senog, Yoon-Bok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.218-223
    • /
    • 2012
  • This study is focused on the evaluation of thermal output of TABS (Thermally Activated Building System). The aim of this study is to evaluate TABS in terms of the temperature difference between heating medium supply temperature ($T_s$) and return temperature ($T_r$), thermal output and the surface temperature distribution according to the design flow rate and the design flow temperature. Through the transient heat transfer simulation using temperature calculation using Crank-Nicolson FDM using Physibel Voltra 6.0 W, the temperature difference between $T_s$ and ��$T_r$, thermal output and the surface temperature distribution of specific TABS was calculated and evaluated. The results show that specific thermal output and temperature difference at $60^{\circ}C$ of supply water temperature were about 162 $W/m^2$, $13.6^{\circ}C$ respectively.

Measurement method for control valve noise (콘트롤 밸브의 소음 측정 방법)

  • Lee Y. B.;Yoon B. R.;Park K. A.;Lee D. H.;Yoo S. H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.515-518
    • /
    • 2002
  • 콘트롤밸브는 지역 냉${\cdot}$난방 및 APT, 대형 빌딩의 냉온수, 중온수 및 공조배관 시스템에 사용되어 유체적 바란스를 이루는데 사용된다. 이와같이 유체의 흐름을 조절하기 위하여 사용되는 콘트롤 밸브가 때로는 소음 문제를 일으키기도 한다. 최근 들어 밸브의 소음이 문제가 되는 경우가 빈번해 지고 있다. 밸브의 기본적 기능을 충족시키기 위해서는 영구적인 수두 손실이 필요하며 이러한 수두손실을 발생시키는 과정에서 유체 흐름에 의해 발생한 난류가 커다란 밸브 소음을 유발하게 된다. 본 연구에서는 콘트롤 밸브 소음 특성 평가 방법을 검토하였다. 밸브 및 배관으로 이루어진 시스템에서 발생되는 소음을 예측하는 절차를 살펴보았다. 밸브의 음향 파워레벨을 측정하고 유량 및 차압의 변화에 따른 소음 예측식을 결정 하였다. 본 연구에서 제시한 밸브 소음 측정 방법은 새로운 밸브의 소음특성 평가, 밸브 소음의 예측 그리고 서로 다른 밸브 사이의 성능비교 등에 사용될 수 있을 것이다.