• Title/Summary/Keyword: 에너지 기여도 평가

Search Result 1,107, Processing Time 0.028 seconds

Emergy Evaluation of Typhoon Maemi in Busan (태풍 매미가 부산시에 미치는 영향에 대한 에머지 평가)

  • Park, KyungMin;Kim, Dong-Myung;Lee, Suk Mo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.20 no.1
    • /
    • pp.18-25
    • /
    • 2017
  • Damage of both life and property has been increased by natural disaster under the influence of climate change, thus many natural disaster vulnerability researches have been carried out to make adaptation policy and impact assessment of climate change recently. Their method for assessing vulnerability usually have used proxy variables for making vulnerability indices. However, because their results were too qualitative and relative it tends to be hard to make absolute comparison and establish standard of prevention or adaptation ability. Accordingly, this study aimed at quantifying natural disaster vulnerability using emergy through recognizing disaster as the relations between order and disorder by system approach. As a result, ordering energy (4.66E+22 sej/yr) and ordered structure (1.98E+22 sej) of Busan in 2003 and disordering energy (7.80E+18 sej), disordered parts (4.55E+20 sej) and rebuilding energy (3.87E+20 sej) by typhoon Maemi were analysed. And then, this was compared with Hurricane Andrew in Dade County. Through this comparison, if the prevention ability of Busan increases, disordered parts can be reduced against the more powerful disordering energy. Also, prevention for additional damages by disaster is needed to practical rebuilding action. In conclusion, it was able to figure out the impact of disaster quantitatively by natural systems and urban systems showing as common measure. Based on this study and further research to make effective prevention for how much prevention ability should be increased will contribute to producing the scientific data for disaster management policy in future.

Analysis on the Energy Performance of Solar Water Heating System according to the Configuration of Flat Plate Collectors (태양열급탕시스템의 집열기 배열에 따른 에너지성능 분석 및 평가)

  • Ko, Myeong-Jin;Lim, Bo-Min;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.49-56
    • /
    • 2016
  • The objective of this work is to analyze the variation in energy performance for each flat plate collector connected in series. In this study, it was assumed that solar water heating system with annual solar fraction of 60% was installed in an office building in Seoul, South Korea. The transient energy performance corresponding to four cases, which are selected using different solar radiation and outdoor air temperature, is studied by analyzing the variation in outlet temperature, solar useful heat gain, and thermal efficiency of each collector. It is observed that the useful heat gain and the collector efficiency decrease continuously, and outlet temperature increases when increasing the number of collector connected in series. The long-term performance is assessed by evaluating the thermal efficiency of each collector for two solar radiation conditions ranging from 780 to $820W/m^2$ and from 380 to $420W/m^2$. It is found that the differences between the intercept and slope of the efficiency curves for first and eighth collectors are 3.68% and 6.74% for solar radiation of $800{\pm}20W/m^2$ and 8.57% and 12.90% for solar radiation of $400{\pm}20W/m^2$, respectively. In addition, it is interesting to note that annual useful heat gain and collector efficiency are reduced with similar rate of about 6.13% when increasing the collector area by connecting the collectors in series.

Design and Performance Estimation of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner (열처리로용 소형 축열식 복사관 버너의 축열기 설계 기술평가)

  • Cho H. C.;Cho K. W.;Lee Y. K.
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.291-295
    • /
    • 2004
  • Heat regenerator attached in small-scale regenerative radiant tube burner was designed using the theoretical computation code and was confirmed the performance of waste heat recovery ratio. From the computation, when ceramic ball of 4-5kg was used, temperature efficiency and available waste heat recovery ratio were predicted 80% and 70%, respectively. Similar efficiencies were obtained from the experiments using LPG. However, since exhaust gas temperature entered into regenerator was below 850$^{\circ}C$ which was moth lower than that we expected. air preheating temperature was lowered below 800$^{\circ}C$.

Design, Fabrication and Performance Analysis of Fiber Optic Concentrators for Daylighting (자연채광을 위한 화이버 광학 집광기의 설계, 제작 및 성능 평가)

  • Han, Hyun-Joo;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.129-136
    • /
    • 2007
  • 자연광의 이용은 큰 어려움 없이 지속 가능한 에너지 기술을 구현할 수 있는 방안으로 고려되고 있다. 여러 개의 작은 반사경을 적용한 태양 추적식 자연채광 시스템은 비교적 단순한 메카니즘을 적용하여 그 성능과 효용성의 극대화를 꾀할 수 있으며, 또한 그 제작, 설치 작동 그리고 활용성에서 상당한 이점이 있다. 본 연구에서는 작은 mini-dish형 반사경(직경<30cm 이하)을 이용한 화이버 광학 집광기의 설계, 제작 및 작동 특성에 대하여 소개하고, 아울러 광추적 프로그램인 Photopia를 이용하여 그 성능에 대한 시뮬레이션을 수행하였다. 주요 구성 요소에서의 광추적에 의한 시뮬레이션 결과치는 실제 시스템의 설계 및 성능 예측에 중요한 기술적 데이터를 제공하며, 특히 실측이 곤란한 측정 면에서의 빛의 경로 해석에 유용하게 적용될 수 있다.

Applied Method of Energy Harvesting for Multi-Relay Environment (다중 중계기 환경에 대한 에너지 하베스팅의 적용 방안)

  • Kim, Tae-Wook;Kong, Hyung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.69-74
    • /
    • 2014
  • In this paper, an energy harvesting scheme is investigated in the multi-relay cooperation communication. Our proposal is to maximize the diversity gain and overcome the disadvantages of the limited power wireless devices. The best relay is selected based on the maximizing channel gains from source to relays so that the harvested energy at selected relay is best. If an internal power of the best relay is lower than a defined target power, the best relay will harvest the energy from the source, and the help of the source-destination link is changed to the second best relay. By this operation method, the diversity gain is maintained and the performance of the network is improved. Finally, performance of the proposed protocol is analyzed in terms of bit error rate, utilization efficiency, power collection efficiency.

Study on the Low Energy Sewage Management Based on Pre-sensing Technology and Automatic Blower Control (사전감지기술 및 송풍량 자동제어를 기반으로 한 저에너지 하수관리기술에 관한 연구)

  • Lee, Seungmyoung;Kim, Hanlae;Ki, Kyoungseo
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.592-603
    • /
    • 2019
  • This study is about the implementation of low energy sewage management technology through effective control of blower which consumes the most energy in sewage treatment. In calculating the amount of oxygen required for microorganisms, unlike the existing method using the operating index in the bioreactor or TMS data in the discharge port, the CODcr and NH4+-N concentration changes in sewage flowing into the sewage treatment plant were detected in advance before entering the bioreactor and the amount of air was controlled based on this. The pre-sensing was found to have a high correlation compared with conventional products. As a result of blower control, it was possible to save about 9.9% energy more than the manual control. Consequently, this study suggested the possibility of blower's real-time control combined with pre-sensing technology. Also, it is expected that the low energy sewage treatment can be applied to sewage treatment facilities dependent on operation by manpower, and it will contribute to the reduction of greenhouse gas emissions.

Assessment of Neutron Skyshine Dose in a Cargo Inspection Facility Using High Energy X-ray (고에너지 X-ray를 이용한 화물검색시설에서의 중성자 Skyshine 방사선량률 평가)

  • Cho, Young-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.27-31
    • /
    • 2008
  • The radiation protection measures for the photoneutrons are one of the most important issue of radiation safety in high energy X-ray facilities. When the photoneutrons are released from the facility, the general public as well as occupational workers are exposed to unexpected radiations by neutron skyshine effect. In this study, the photoneutron inventory are calculated using monte carlo mothed, and the neutron skyshine dose rate is assessed using the inventory. A 9MeV X-ray cargo inspection facility is considered as a reference facility.

  • PDF

Evaluation of Storage Engine on Edge-Based Lightweight Platform using Sensor·OPC-UA Simulator (센서·OPC-UA 시뮬레이션을 통한 엣지 기반 경량화 플랫폼 스토리지 엔진 평가)

  • Woojin Cho;Chea-eun Yeo;Jae-Hoi Gu;Chae-Young Lim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.803-809
    • /
    • 2023
  • This paper analyzes and evaluates to optimally build a data collection system essential for factory energy management systems on an edge-based lightweight platform. A "Sensor/OPC-UA simulator" was developed based on sensors in an actual food factory and used to evaluate the storage engine of edge devices. The performance of storage engines in edge devices was evaluated to suggest the optimal storage engine. The experimental results show that when using the RocksDB storage engine, it has less than half the memory and database size compared to using InnoDB, and has a 3.01 times faster processing time. This study enables the selection of advantageous storage engines for managing time-series data on devices with limited resources and contributes to further research in this field through the sensor/OPC simulator.

A Study on a Robust Voice Activity Detector Under the Noise Environment in the G,723.1 Vocoder (G.723.1 보코더에서 잡음환경에 강인한 음성활동구간 검출기에 관한 연구)

  • 이희원;장경아;배명진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.173-181
    • /
    • 2002
  • Generally the one of serious problems in Voice Activity Detection (VAD) is speech region detection in noise environment. Therefore, this paper propose the new method using energy, lsp varation. As a result of processing time and speech quality of the proposed algorithm, the processing time is reduced due to the accurate detection of inactive period, and there is almot no difference in the subjective quality test. As a result of bit rate, proposed algorithm measures the number of VAD=1 and the result shows predominant reduction of bit rate as SNR of noisy speech is low (about 5∼10 dB).

Improvement of VAD Performance for the Reduction of the Bit Rate Under the Noise Environment in the G.723.1 (잡음 환경에서의 전송률 감소를 위한 G.723.1 음성활동 검출기 성능 개선에 관한 연구)

  • 김정진;장경아;배명진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.42-47
    • /
    • 2001
  • This paper improves the performance of VAD (Voice Activity Detector) in G.723.1 Annex A 6.3kbps/5.3kbps dual rate speech coder, which is developed for Internet Phone and videoconferencing. The VAD decision is based on a three-level energy threshold. We evaluates for processing time, speech quality, and bit rate. The processing time is reduced due to the accuracy of VAD decision on the silence period. On subjective quality test there is almost no difference compared with the G.723.1. In order to measure the bit rate we count the active speech frame (VAD=1) and we can reduce more bit rate as silence periods are shown.

  • PDF