• Title/Summary/Keyword: 방사선 장비

Search Result 593, Processing Time 0.028 seconds

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

Performance Testing of Medical US Equipment Using US Phantom(ATS-539) (Focusing on Daegu Region) (초음파팬텀(ATS-539)을 이용한 의료용 초음파장비의 성능검사(대구지역을 중심으로))

  • Kim, Do-Hyung;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.295-305
    • /
    • 2014
  • This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

Comparison of the Values of Bone Mineral Density Between DEXAs (DEXA 측정기 간 골밀도 값 비교)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.271-276
    • /
    • 2011
  • Statistical analysis was performed on the patients who took bone densitometry using Lunar and Hologic equipments for 5 months from January $1^{st}$ 2010 to May $30^{st}$, 2010. Patients consisted of 50 in their 40s, 100 in 50s and 50 in 60s. In addition, the results from bone densitometry were carried out on the same subject with two equipments on the same day. In case of 200 subjects, who received the bone densitometry with two equipments, the average age was 54.5 and 54.4 years old, respectively. There was no difference. The T- score of Lunar equipment was $-1.377{\pm}1.221$ and that of Hologic equipment was $-1.806{\pm}1.123$. The T-score of Lunar equipment was measured higher than that of Hologic equipment. T-test was conducted to determine the equality of the mean of two groups with 200 patients. Since the pvalue was 0.000, the value of bone mineral density was significant in two equipments. Furthermore, the patients, who were diagnosed by Lunar, showed more 'normal' and who were diagnosed by Hologic, showed more osteoporosis, which cartegorized by WHO, such as normal, osteopenia, and osteoporosis. Thus, compared results of bone densitometry on lumbar spine L1 - L4 of four normal people with the same equipment showed that T- score of Lunar equipment was $-0.4{\pm}1.2$, and T- score of Hologic equipment was $-1.1{\pm}1.5$. It showed the higher T- score was measured in Lunar equipment as well. Therefore, the correction factor should be considered to use, since T- scores are different between two equipments.

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Calculation of Shielding Rate and Dose Distribution of Space of L-Block-Type Protective Equipment for Radioactive Fluorine using the Monte Carlo Method (몬테칼로 방법을 이용한 방사성 불소에 대한 L-블럭형 방호장비의 차폐율 및 공간의 선량분포 계산)

  • Han, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.813-819
    • /
    • 2021
  • In this study, the shielding rate of L-block-type shielding equipment used for radiation protection when radioactive fluorine is injected into the human body and the dose distribution of the space in the injection room were calculated using the Monte Carlo method. The shielding rate of the body and window parts of the L-block-type shielding equipment was 99.99%. The dose distribution calculated at a distance of 1 m was relatively high at 135°, 45°, 225°, 315°, and 180° of the XZ plane, and was calculated to be very low at 0°, 90°, and 270°. In the YZ plane, it was relatively high at 135°, 180°, and 225°, and was calculated very low at the remaining angles. The AZ and BZ planes also showed similar results to the YZ plane. In addition, it was confirmed that the shielding rate was the best in the range of 225° to 315° through the dose distribution in the horizontal direction of the source and the 45° direction above the source. These results can be used as basic data necessary for radiation protection of radiation workers.

A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021 (보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.667-673
    • /
    • 2021
  • As we enter the era of the 4th industrial revolution, it is judged that the scope of work of radiologists will be further expanded according to the innovation and advancement of radiation medical technology development. In this study, the current status of medical equipment and radiology technicians was identified, and basic data were provided for the plan for nurturing talents in the field of radiation medical technology in the era of the 4th industrial revolution, as well as career and employment counseling. Data from the second quarter of 2020 and the second quarter of 2021 were analyzed using health and medical big data. As a result of comparing the status of medical equipment by type in 2021 compared to 2020, C-Arm X-ray examination equipment increased by 5.83% to 6,638 units, followed by MRI examination equipment 1,811 units 5.29%, and angiography equipment 725 units 5.22% , general X-ray examination equipment 21,557 units increased 3.99%, CT examination equipment 2,136 units 3.03%, and breast examination equipment 3,425 units increased 3.00%. As a result of a comparison of the total number of radiologists in 2021 compared to 2020, the number was 29,038, an increase of 2.73%. As a result of comparing the status of radiographers by region, the increase was highest in the Gyeonggi region with 5.96%, followed by the Gangwon region with a 5.66% increase and the Chungnam region with a 3.81% increase. In a situation where the number of medical equipment and radiologist manpower is increasing, universities are developing specialized knowledge and practical competency through subject development related to the understanding and utilization of customized artificial intelligence and big data that can be applied in the medical radiation technology field in the era of the 4th industrial revolution. It is necessary to nurture qualified radiographers, and at the level of the association, it is thought that active policies are needed to create new jobs and improve employment.

Radiologic Equipment and Technicians according to the Distribution of the Population (인구 분포에 따른 방사선 장비 및 종사자에 관한 고찰)

  • Yoon, Chul-Ho;Choi, Jun-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.57-65
    • /
    • 2009
  • Purpose: The purpose of this paper is to provide basic data in order to systemize the management of demand and supply of radiologic technicians, to pursue a fair regional distribution of educational institutions, and furthermore to keep reasonable medical treatment and fee. This research was carried out through the investigation of radiologic equipments and technicians according to the distribution of the population. Materials and Methods: We compared and analyzed the correlation between regional population, the number of clinics and hospitals, the number of medical imaging devices, and the number of radiologists and radiologic technicians in 5 cities without "Gu" administrative units in 2008. Results: 27,317 radiologic technicians have been produced since the administration of the national qualifying exam for radiologic technicians. About 18,000 radiologic technicians are currently working. There are 39 colleges or universities with Departments of Radiology and the admission quota is 2,120 students excluding one college. The ratio of radiologic equipments to radiologic technicians is 2.6 to 1. Conclusion: There is a dilemma in which some radiologic technicians fail to find appropriate jobs while some clinics or hospitals are in need of radiologic technicians. This dilemma is due to unreasonable regional discrepancies in pay system and welfare situation, and excessive profit-oriented recruiting system of clinics and hospitals. The increase of students of Radiologic Departments and approval of additional departments will end up with producing superfluous high academic degree holders, which is on the contrary to the government policy to produce more job opportunities. So the policy of increasing Radiologic Departments should be reconsidered.

  • PDF

Empirical Study on the Value Comparison Between Cosmic Radiation Measuring Instruments and Prediction Programs (항공기 탑재 우주방사선 측정장비와 예측프로그램의 비교값 실증연구)

  • Kyu-Wang Kim;Youn-Chul Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.755-762
    • /
    • 2023
  • The reliability of measuring instruments is essential in measuring cosmic radiation. To demonstrate this importance, this study measured and compared the amount of cosmic radiation using Liulin and TEPC, operated in South Korea, on a flight between Incheon, South Korea and LA, the US. In addition, since prior analysis based on a prediction program is necessary in advance to check the dose of cosmic radiation, this study utilized KREAM developed in Korea and the CARI-6M developed by the FAA to acquire the predicted value. As a result of the verification, the reliability of the two devices falls within the acceptable level of 20%, proving the reliability. Moreover, the differences between the values acquired by each prediction program were only subtle. Nevertheless, the analysis demonstrated that the prediction value obtained by the programs and the measured value had significant differences. Therefore, additional correction of the discrepancies or continuous research for such is required to match the predicted values are similar to the actual measured values.

Development of Remote Control Laboratory for Radiation. Detection via Internet (인터넷을 통한 방사선 측정 원격 제어 실험실 개발)

  • Park, Sang-Tae;Lee, Hee-Bok;Yuk, Keun-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2002
  • The role of experiments in science education is essential for understanding the natural phenomena and principle related to a subject. Therefore, the remote control experiment via Internet is one of key solution for distance learners in science education. The remote experiments ate also necessary for the time-consuming experiment which takes several days, collaborative experiment between distance learners, expensive laboratory equipment which is not usually available to students, experimental procedure which is dangerous, etc. In this study, we have developed a general method for a remote control laboratory system using internet and interlace techniques. It is possible for students to learn the nuclear physics to control the real instruments and conduct physics experimentation with internet techniques. We proposed the remote control radiation measurement system as a sample application. This system could be useful for the monitoring near a nuclear power plants in order to improve the environment data credibility to the public.

A Study of Magnification of Cardiac Size and Cardiothoracic Ratio on Chest Posteroanterior Projection in Digital Radiography System (디지털방사선 환경에서 흉부 후.전방향 검사 시 심장과 심흉비 확대에 관한 연구)

  • Joo, Young-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.195-196
    • /
    • 2014
  • 현재 디지털방사선 환경으로 변화하고 있는 추세에 과거 필름-스크린 방식에서 사용되던 흉부 후 전 방향 검사 시 초점 영상 수신부 간의 거리가 디지털방식의 장비에도 여전히 적용되고 있다. 이에 본 연구에서는 3개의 DR장비에서 각 영상수용체의 제조특성을 고려하였을 때 실제 심장 및 심흉비의 확대정도에 대해 알아보고, 임상에서 DR 장비를 이용한 Chest PA 검사 시 심장 및 심흉비의 확대도에 대한 정보를 제공하고자 한다.

  • PDF