• Title/Summary/Keyword: 레디믹스트 콘크리트

Search Result 35, Processing Time 0.023 seconds

Study on Early Development Properties of Concrete Strength in each Strength Level (강도 수준별 콘크리트 조기강도 특성에 관한 연구)

  • Jeong, Jae-Gwon;Choi, Yun-Wang;Lee, Kwang-Myong;Kim, Jee-Sang;Moon, Jae-Heum;Park, Man-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.413-414
    • /
    • 2009
  • In this study, the concrete being used for normal and high strength concrete section was manufactured to develop and set up optimized concrete materials for domestic ready-mixed concrete. And the domestic and overseas level of early strength manifested was compared and reviewed.

  • PDF

Computer Program for Quality Control of Ready Mixed Concrete (레디믹스트 콘크리트의 품질관리 프로그램 개발)

  • 최재진;박원태
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • To make practical application of mixing test results to concrete mix design, experimental tests of concrete were done and the relationship between cement-water ratio and compressive strength of concrete was obtained. A computer program which can be used for data base of air content, slump and compressive strength test results was developed. The program draws $\bar{X}$-R or X-Rs control charts and has data sheets for arrangement of material test results. The computer program also helps calculation of concrete mix proportions for mixing tests and contains dictionary of concrete technical terms.

  • PDF

Property Evaluation of the Concrete Replacing 5-13mm Recycled Coarse Aggregates (5~13mm 입도분급 순환 굵은 골재 혼합사용에 따른 콘크리트의 특성평가)

  • Han, Min-Cheol;Song, Young-Wo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • This paper is to investigate experimentally the effect of substitution of recycled coarse aggregate(RCA) under 13mm on the engineering properties of the concrete using gap graded coarse aggregates. Concretes with 0.4 of water to cement ratio(W/C) were fabricated to achieve 30MPa of design strength with coarse aggregate over 13mm in size with the maximum size of 25mm. RCA was substituted for coarse aggregate over 13mm from 10% to 50% and crushed coarse aggregate under 13mm was also substituted for coarse aggregate over 13mm from 20% to 40%, respectively. Test results indicated that the replacement of RCA up to 20% resulted in an increase of fluidity and strength. It also caused a decrease in the drying shrinkage due to dense packing effect by achieving continuous grading of mixed aggregates. For practical application of RCA, when properly substituted, the use of RCA enabled the concrete to reduce water contents and sand to aggregate ratio in mixing design stage of the concrete. And, it can also enhance the compressive strength of the concrete.

A Study on the Properties of Ready Mixed Concrete Quality in Site by Statistical Analysis (통계분석에 의한 현장 타설 콘크리트의 품질 특성에 관한 연구)

  • Ji, Suk-Won;Jung, Si-Jin;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.171-180
    • /
    • 2007
  • The quality of ready-mixed concrete(henceforth abbreviated remicon) is influenced by various factors such as ingredient of material, difference of property, mixing ratio, mixing time, mixing error, conditioning of construction, method of curing and temperature, humidity time in transportation. These factors make it hard to confirm the quality of remicon till placing in site. As the quality control in field is very important to ensure the quality of building. Moreover in modern building production, the more important the inquiry of performance improvement, the more important the manufacture and the quality control of remicon. In this study, to examine and analyze the quality of remicon we used slump, air content and compressive strength in 7, 28 days as to remicon which placed during on year. As a result, we found that the slump and air content were satisfied with reference code and the compressive strength was more than the design standard strength so we concluded that the quality control of remicon was to be agreeable.

A Grope of Development Direction for the New Ready-mixed Shotcrete through the Batch Plant in Field (현장 배치플랜트 실태조사를 통한 새로운 레디믹스트 숏크리트 개발 방향 모색)

  • Ma, Sang-Joon;Lee, Heung-Soo;Choi, Hee-Sup;Kim, Dong-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.845-848
    • /
    • 2008
  • In this study, through the Batch Plant in field which is carrying out in the country, this research is going to grope the development of Ready-mixed Shotcrete that can improve the construction of shotcrete, and long-term durability. Accordingly, in this study, the Batch Plant in field which is only for shotcrete will be chosen in random so that can be aware the problems of the Batch Plant in field, and when the results come out, the shotcrete system will be prepared that is based on the results of rsearch, and also can be used in preparation index of shotcrete. Moreover, the results will be able to improve an efficent tool that can increase shotcrete quality.

  • PDF

A Study on Manufacture standardization of High Strength Concrete to Use Moderate Heat Portland Cement (벨라이트계 시멘트를 이용한 고강도 콘크리트 제조표준화에 관한 연구)

  • Park, Cheol;Kim, Dong-Suck;Um, Tai-Sun;Lee, Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.665-668
    • /
    • 2008
  • Recently the city construction and the concrete structures are more becoming extra weight and the efficient use of the space by the population intensively and follow in industrial intensive commerce and the residence commerce composition building which leads the high story of the building. Consequently the high rise of the building which space applies efficiently in objective which will increase continuously. Also with high rise of buildings durability it will be able to increase the life of the structure is emphasized and the concrete structure is demanding the more high strength.

  • PDF

A Fundamental Study for Proper Maximum Size of Coarse Aggregate of Ready-mixed Shotcrete (레디믹스트 숏크리트의 적정 골재최대치수 제안을 위한 기초적 연구)

  • Ma, Sang-Joon;Choi, Hee-Sup;Kim, Dong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 2008
  • This study was carried out to investigate and analyse the influence of maximum size of coarse aggregate and quality control of aggregate on the properties of shotcrete through the laboratory and field test. From the results of the test, as the maximum size of coarse aggregate decreased from 13 mm to 8 mm, plasticity property declined and compressive strength and dynamic modulus of elasticity of hardened concrete increased remarkably, so it was found that the aggregate size 8 mm was superior to 13, 10 mm in fluidity, constructability and durability. Therefore, it was advisable for well maximum size of coarse aggregate to apply to the 8mm aggregates through the Ready-mixed Method for quality control and minimum segregation.

Mock-up Test on Concrete added Admixture for Reducing the Dry Shrinkage (건조수축 저감제를 혼입한 콘크리트의 Mock-up test)

  • Park, Heung-Lee;Lee, Jong-Rok;Choi, Myung-Hwa;Park, He-Gon;Song, In-Myung;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.773-776
    • /
    • 2008
  • Restraining cracks on concrete structures can be the basic condition to improve the durability, so in this research, the resistibility on the drying shrinkage of concrete structures in the long period was being confirmed and as the reason of this shrinkage, the density of minute textures was being analyzed using a wooden prototype of a full scale produced with ready-mixed concrete and agents of glycol which can be used as a surfactant. As result of those tests, PFB technology can reduce the drying shrinkage by approximately $-100{\sim}200{\times}10^{-6}$ on a wooden prototype of a full scale and can also reduce the pore volume as the obstruction to the movement of gas or liquid by approximately $2.4{\sim}3.5$% so that PFB technology can be used to assure the resistibility on the drying shrinkage.

  • PDF

Analysis of the Mixing Conditions by Domestic Ready-Mixed Concrete Rage Sphere (국내 레미콘의 권역별 배합특성에 관한 분석 - 경기 및 경상권역을 중심으로 -)

  • Seo, Hwi-Wan;Kim, Young-Il;Kang, Ghang-Un;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.131-132
    • /
    • 2011
  • This study analyzes the yearly-best delivered size range of truck mixer based on the specified mix, Water to Binder Ratio, aggregate proportion and unit amount with statistical method targeting on Kyeongi and Kyeongsang province and compares with the similar materials of Japan to propose as a basic standard for the quality control of mixer truck. As a result, in case of the Water to Binder Ratio of these areas, it is higher than Japan's due to the excessive safety rate reflecting the changes of differential value impact and unit amount, and the unit amount's standard deviation is very large by reflecting the changes of the amount used and chemical admixture susceptibility. In case of aggregate proportion, the frequency rate is about 50%, which is very similar value with Japan's one.

  • PDF

A Survey Study on the Shipment Volume of the Ready-Mixed Concrete (출하 된 레미콘의 용적실태에 관한 조사연구)

  • Jo, Man-Ki;Kwak, Yong-Jin;Kim, Jun-Ho;Son, Seok-Heon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.72-73
    • /
    • 2013
  • In this paper, types of ready mixed concrete in construction site supported by different company has been researched. The practicability of the commercial available ready mixed concrete has been tested, and the standard deviation has been modified from Vc=Vo+3б to Vc=Vo+1.73б. Unnecessary premium rate has been cut and economical efficiency of the ready mixed concrete has been improved.

  • PDF