• Title/Summary/Keyword: 네트워크 클럭

Search Result 52, Processing Time 0.03 seconds

A Byzantine Fault-tolerant Clock Synchronization Scheme in Wireless Sensor Networks (무선 센서 네트워크에서 비잔틴 오류를 허용하는 클럭 동기화 기법)

  • Lim, Hyung-Geun;Nam, Young-Jin;Baek, Jang-Woon;Ko, Seok-Young;Seo, Dae-Wha
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.5
    • /
    • pp.487-491
    • /
    • 2008
  • This paper proposes the Byzantine fault tolerant clock synchronization scheme for wireless sensor networks to cope with the clock synchronization disturbance attack of malicious nodes. In the proposed scheme, a node which is requiring clock synchronization receives 3m+1 clock synchronization messages not only from its parent nodes but also from its sibling nodes in order to tolerate malicious attacks even if up to m malicious nodes exist among them. The results show that the proposed scheme is 7 times more resilient to the clock synchronization disturbance attack of malicious nodes than existing schemes in terms of synchronization accuracy.

Recursive Clock Skew Estimators for Time Synchronization in Wireless Sensor Networks (무선 센서네트워크에서의 시각동기를 위한 재귀적 클럭 스큐 추정 방법)

  • Kim, Dongjin;Maeng, Seyeong;Bang, Jongdae;Lee, Yeonwoo;Jung, Min-a;Lee, Seong Ro
    • Annual Conference of KIPS
    • /
    • 2012.04a
    • /
    • pp.1035-1037
    • /
    • 2012
  • 무선 센서네트워크에서의 시각동기는 MAC 계층에서부터 APP 계층에 이르기까지 거의 모든 계층에서 다양한 목적을 위해 매우 중요한 기술이다. 본 논문에서는 무선 센서네트워크에서의 에너지 효율적인 시각동기를 위한 실시간 클럭 스큐 추정 방법을 제시한다. 재귀적 최소제곱법을 통해 오프셋 보정 정보들을 얻을 때마다 클럭 스큐가 실시간적으로 추정 및 갱신되며, 아울러 스큐 추정을 위해 각 센서노드에 저장해야할 정보를 최소화한다. 제안한 클럭 스큐 추정 방법은 기존의 클럭 오프셋 보정 방법과 쉽게 통합될 수 있으며, 이 경우 보다 정확하고 효율적인 시각동기화가 가능해진다. 시뮬레이션 및 실험 결과를 통해 제안한 클럭 스큐 추정 방법을 통한 시각동기 정확도의 향상을 보인다.

Realtime Clock Skew Estimator for Time Synchronization in Wireless Sensor Networks of WUSB and WBAN (무선 센서네트워크에서의 시각동기를 위한 실시간 클럭 스큐 추정)

  • Hur, Kyeong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.11
    • /
    • pp.1391-1398
    • /
    • 2012
  • Time synchronization is crucial in wireless sensor networks such as Wireless USB and WBAN for diverse purposes from the MAC to the application layer. This paper proposes online clock skew estimators to achieve energy-efficient time synchronization for wireless sensor networks. By using recursive least squares estimators, we not only reduce the amount of data which should be stored locally in a table at each sensor node, but also allow offset and skew compensations to be processed simultaneously. Our skew estimators can be easily integrated with traditional offset compensation schemes. The results of simulation and experiment show that the accuracy of time synchronization can be greatly improved through our skew compensation algorithm.

Performance Analysis of Multibuffered Multistage Interconnection Networks using Small Clock Cycle Scheme (작은 클럭 주기를 이용한 복수버퍼를 가지는 다단 상호연결 네트워크의 해석적 성능분석)

  • Mun, Young-Song
    • Journal of Internet Computing and Services
    • /
    • v.6 no.4
    • /
    • pp.141-147
    • /
    • 2005
  • Ding and Bhuyan, however, has shown that the performance of multistage interconnection networks(MIN's) can be significantly improved if the packet movements are confined within each pair of adjacent stages using small clock cycles. In this paper, an effective model for estimating the performance of multibuffered MIN's employing the approach is proposed. the relative effectiveness of the proposed model is identified compared to the traditional design.

  • PDF

Fault Tolerant Clock Management Scheme in Sensor Networks (센서 네트워크에서 고장 허용 시각 관리 기법)

  • Hwang So-Young;Baek Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9A
    • /
    • pp.868-877
    • /
    • 2006
  • Sensor network applications need synchronized time to the highest degree such as object tracking, consistent state updates, duplicate detection, and temporal order delivery. In addition, reliability issues and fault tolerance in sophisticated sensor networks have become a critical area of research today. In this paper, we proposed a fault tolerant clock management scheme in sensor networks considering two cases of fault model such as network faults and clock faults. The proposed scheme restricts the propagation of synchronization error when there are clock faults of nodes such as rapid fluctuation, severe changes in drift rate, and so on. In addition, it handles topology changes. Simulation results show that the proposed method has about $1.5{\sim}2.0$ times better performance than TPSN in the presence of faults.

Modeling of Input Buffered Multistage Interconnection Networks using Small Clock Cycle Scheme (작은 클럭 주기를 이용한 다단 상호연결 네트워크의 성능분석)

  • Mun Youngsong
    • Journal of Internet Computing and Services
    • /
    • v.5 no.3
    • /
    • pp.35-43
    • /
    • 2004
  • In packet switching using multistage interconnection networks (MIN's), it is generally assumed that the packet movements successively propagate from the last stage to the first stage in one network cycle. However, Ding and Bhuyan has shown that the network performance can be significantly improved if the packet movements are confined within each pair of adjacent stages using small clock cycles. In this paper, an analytical model for evaluating the performance of input-buffered MlN's employing this network cycle approach is proposed, The effectiveness of the proposed model is confirmed by comparing results from the simulation as well as from Ding and Bhuyan model.

  • PDF

디지틀 망동기

  • Kim, Ok-Hui;Park, Gwon-Cheol
    • ETRI Journal
    • /
    • v.8 no.2
    • /
    • pp.45-52
    • /
    • 1986
  • 교환망이 점차로 디지틀화 되면서 네트워크내의 클럭 주파수의 불일치에 의해 야기되는 slip 발생에 따른 정보손실은 중요한 문제점으로 대두되었으며 모든 디지틀 교환기는 네트워크내의 기준 주파수에 자체 클럭을 동기시키기 위한 망동기 기능을 수용하며 silp 발생을 방지하고 있다. TDX-1에서는 국내 교환망 동기 체계에 적합한 동기회로계를 개발하여 망동기를 성취하고 있으며 본고는 이 회로계의 특성에 대해 논하고자 한다.

  • PDF

Clock Synchronization and Biped Robot control application based-on TMO-eCos (TMO-eCos 기반 클럭 동기화 설계 및 2족 보행 로봇 제어 응용)

  • Oh, Yong-Seok;Kim, Jung-Guk;Lee, Seung-Yun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06b
    • /
    • pp.372-376
    • /
    • 2007
  • 분산처리 시스템은 네트워크로 연결된 프로세서들로 구성되며, 시스템 내의 각 프로세서는 고유한 클럭을 갖는다. 글로벌 시간 기준으로 볼 때 수행중인 프로세스가 유지하는 시간은 분산시스템 각각 차이가 있을 수 있으므로 일관성 있는 시간관리가 필요하다. 본 논문에서는 TMO-eCos를 기반으로 하는 분산 처리 시스템에서 각 분산 시스템간 발생할 수 있는 클럭의 불일치 문제를 해결하기 위한 클럭 동기화 기법에 관해 논한다. 점진적인 클럭 동기화 알고리즘을 구하기 위해 마스터 노드의 클럭을 글로벌 클럭으로 가정하고 슬레이브 노드들은 마스터 노드의 클럭으로 동기화하는 방법에 대하여 정의하였다. 정의한 알고리즘을 시현하기 위한 분산 노드 간 로봇 제어 프로그램을 소개 한다.

  • PDF

Research of Time Synchronization Protocol for Ubiquitous Sensor Network (센서네트워크를 위한 시간동기화 프로토콜 연구)

  • Jeong, Keong-Ja
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.746-749
    • /
    • 2009
  • 유비쿼터스 센서 네트워크에서 사용되는 센서노드는 동종의 센서 노드와 많은 수의 이기종 센서 노드들을 포함하게 된다. 이기종 센서노드들간의 시간동기화로 인한 배터리 전력소모를 최소화하기 위해서 본 논문에서는 싱크노드 아래에 있는 싱크노드와 클럭소스가 같은 동종 센서노드를 시간동기 마스터로 설정하고, 싱크노드와 다른 클럭소스를 가지는 다수의 이기종 센서노드를 마스터 아래에 속하는 시간동기 슬레이브로 설정하여 시간동기 마스터가 동작을 개시할 때에만 시간동기 슬레이브 노드들이 동작하도록 동기화하는 이기종 센서노드들의 시간동기화 기법을 제안한다.

  • PDF

Implementation of an Improved Time Synchronization in Wireless Sensor Networks (무선 센서 네트워크에서의 개선된 시각 동기화 구현)

  • Bang, Sangwon;Sohn, Surgwon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.69-72
    • /
    • 2013
  • 본 논문은 TPSN 알고리즘의 시각 동기화 오차를 개선하기 위하여 Imote2 센서 노드의 클럭 드리프트 특성을 적용하는 개선된 TPSN 알고리즘을 제안한다. 클럭 드리프트의 원인은 주로 수정발진기에 기인한다. 본 연구에서는 온도 및 습도 등 환경 조건이 비슷할 경우에 드리프트가 크게 차이나지 않는다는 실험 결과에 따라 드리프트의 평균값을 구하고 이를 TPSN 동기화 오차 보정에 사용한다. 이때 적용되는 드리프트 특성 값은 센서 노드 설치 이전에 미리 측정하여야 한다. 실험을 통하여 본 논문에서 제안한 개선된 TPSN 알고리즘이 동기화 오차 개선에 효과적임을 확인하였다.

  • PDF