• Title/Summary/Keyword: 공시체 콘크리트

Search Result 264, Processing Time 0.028 seconds

Characteristics of Concrete Polymer Composite Using Atomizing Reduction Steel Slag as an Aggregate (II) (Use of Polystyrene as a Shrinkage Reducing Agent) (아토마이징 제강 환원슬래그를 골재로 사용한 폴리머 콘크리트 복합재료의 특성(II) (폴리스티렌 수축저감재 사용))

  • Hwang, Eui-Hwan;Kim, Jin-Man
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.380-385
    • /
    • 2014
  • Spherical atomizing reduction steel slag was prepared by atomizing technology using reduction steel slag (ladle furnace slag, LFS) generated from steel industry. In order to develop the mass-recycling technology of atomizing reduction steel slag, polymer concrete composite was prepared using spherical atomizing reduction steel slag instead of fine aggregate (river sand) and coarse aggregate (crushed aggregate), depending on the grain size. Different polymer concrete specimens were prepared with the various proportions of polymer binder and replacement ratios of atomizing reduction steel slag in order to investigate the characteristics of polymer concrete composite. Results showed that compressive strengths of polymer concrete specimens decreased with the increase of replacement ratios of atomizing reduction steel slag, but flexural strengths of the specimens showed a maximum strength at the 50% of replacement ratios of atomizing reduction steel slag. It was concluded that addition ratio of polymer binder, which affect greatly on the prime cost of production of polymer concrete, could be reduced by maximum 18.2 vol% because the workability of the polymer concrete was remarkably improved by using the atomizing reduction steel slag. However, further study is required because the mechanical strength of the specimen using atomizing reduction steel slag was greatly reduced in hot water resistance test.

Study on the Direct Tensile Test for Cemented Soils Using a Built-In Cylinder (내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구)

  • Park, Sung-Sik;Lee, Jun-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1505-1516
    • /
    • 2014
  • In this study, a cylinder embedded within cemented soils was used to cause directly tensile failure of cemented soils. An existing dumbbell type direct tensile test and a split tensile test that is most general indirect tensile test were also carried out to verify the developed built-in cylinder tensile test. Testing specimens with two different sand/cement ratios (1:1 and 3:1) and two curing periods (7 and 28 days) were prepared and tested. Total 10 specimens were prepared for each case and their average value was evaluated. Unconfined compression tests were also carried out and the ratio of compressive strength and tensile strength was evaluated. The tensile strength determined by built-in cylinder tensile test was slightly higher than that by dumbbell type direct tensile test. The dumbbell type test has often failed in joint part of specimen and showed some difficulty to prepare a specimen. Among three tensile testing methods, the standard deviation of tensile strength by split tensile test was highest. It was shown that the split tensile test is applicable to concrete or rock with elastic failure but not for cemented soils having lower strength.

Estimation of Fatigue Life of Reinforced Asphalt Pavement Overlay against Reflection Cracking due to Flexural Fracture (보강 덧씌우기 아스팔트 포장의 휨파괴에 의한 반사균열 피로수명 추정)

  • Doh, Young-Soo;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.2 no.4 s.6
    • /
    • pp.101-109
    • /
    • 2000
  • This study was performed to estimate fatigue life of polymer-modified and reinforced overlay asphalt mixtures with respect to reflection cracking in asphalt overlay pavement. In order to achieve the goal, the expedited reflection cracking test method was developed and applied to various mixtures and the results were compared one another with respect to the resistant characteristics of reflection cracking. The theoretical prediction equation of fatigue life for each mixture was suggested based on statistical analysis of experimental test results in the flexural failure mode. Since coefficients of correlation between estimated values and measured values were very high ($r^2=0.95$ or higher), the prediction model can be used for relative comparison of various pavement overlay choices to be used in the field.

  • PDF

The Characteristics of Strength Development and Curing Cycle of the Steam Cured Concrete (증기양생 콘크리트의 양생온도주기와 강도발현 특성)

  • Kim, Kwang-Don;Kim, Choon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.63-71
    • /
    • 2010
  • This paper is about a research of steam curing which is one of the curing methods for accelerating the early-age strength of pre-cast concrete. With cylinder mold and mock-up specimen, the research was executed to study the best cycle of steam curing temperature through quantifying cycle of steam curing and maximum temperature, while the required strength is developed under the early-age. Moreover, causes and measurements for the high temperature of concrete, which is due to the steam curing, and the crack, which occurs when removing steel form, are stated. Ultimately, the economical method of producing, which satisfies early-age strength development and quality assurance while manufacturing PC structure, is stated.

Recycle of the Glass fiber Obtained from the Roving Cloth of FRP II: Study for the Physical Properties of fiber-reinforced Concrete (폐 FRP 선박의 로빙층에서 분리한 유리섬유의 재활용 II: 섬유강화 콘크리트의 물성에 관한 연구)

  • Kim, Yong-Seop;Lee, Seung-Hee;Yoon, Koo-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.1
    • /
    • pp.46-49
    • /
    • 2008
  • Recycling glass fiber, 'F-fiber,' was obtained by the separation of the roving layer from waste FRP and the concrete products or structures were considered for its application. Experiment was carried out for the bending strength of aggregate (2.45 of cement) by weight and F-fiber (density of 1.45, volume ratio to all of the aggregate and the cement). Whereas the specimen containing 1% F-fiber showed the bending strength 23% higher than that without F-fiber after curing far 28 days, the one with 0.5% F-fiber did not give any change. It could be found, therefore, that the minimum mixing amount should be larger than 0.5% fur the strength reinforcement. One of the reinforcing concrete product, bench flume, containing 1% F-fiber showed 21% increment of bending strength In contrast to that without F-fiber.

  • PDF

An Experimental Study on the Impact Resistance of Concrete using Coal Ash and Fiber New Materials (석탄재 및 섬유신소재를 혼입한 콘크리트의 충격저항성에 관한 실험적 연구)

  • Park, Sung-Hyen;Park, Seong-Bum;Jang, Young-Il;Lee, Byung-Jae;Jun, Heum-Jin;Cho, Kwang-Yun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.431-432
    • /
    • 2009
  • This study was performed to verify the impact resistance of concrete using coal ash and fiber new materials. As the results of study, the impact resistance of concrete decreased as the mixing ratio of coal ash increased. When the fiber new materials(GF, HPSF) were mixed to the concrete, its resistance was increased.

  • PDF

A Study of Strength of Stress Block and Analysis of the Flexural Deformation for Concrete Structures (300kgf/$\textrm{cm}^2$, 500kg/$\textrm{cm}^2$, 700kgf/$\textrm{cm}^2$) using Reliablity Theory (신뢰성 이론을 이용한 (300kgf/$\textrm{cm}^2$, 500kg/$\textrm{cm}^2$, 700kgf/$\textrm{cm}^2$) 콘크리트 구조물의 휨변형 해석과 응력블럭의 선택에 관한 연구)

  • 최광진;장일영;송재호;홍원기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.334-339
    • /
    • 1996
  • 본 연구의 목적은 불확실성이 내포되어 있는 콘크리트 구조물을 신뢰성 이론에 근거한 보통강도, 고강도 콘크리트에서의 휨모멘트-곡률관계와 하중변위관계를 해석하는데 그 목적을 두고 있다. 또한 기존의 해석방법과 본 연구에서의 해석방법을 비교하고 각 강도별로 기존에 제안된 응력블럭을 가정, 강도별에 알맞은 응력블럭을 검증하고 본 연구의 해석방버벵 대한 타당성을 증명하는 데 있다. 그래서 기존의 문헌을 통하여 공시체 데이터($\Phi$10$\times$20)에 대한 회귀분석을 이용하여 각 강도별로 곡선식을 모델화하여 제안하였고 이 식을 이용하여 불확실성을 내포하고 있는 몬테카롤로 시뮬레이션을 사용하여 내력을 평가하여 기존연구 해석치와 각 응력블럭을 이용한 본 연구에서의 해석치를 비교검토하여 이 해석방법의 타당성을 증명하는데 있다.

  • PDF

The experimental investigation for the curing condition deduce of the Polymer concrete manhole (폴리머 콘크리트 맨홀의 양생 조건 도출을 위한 실험적 고찰)

  • Kim, Dong-Hun;Han, Jin-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.545-548
    • /
    • 2008
  • 불포화 폴리에스테르 수지를 결합재로 사용하여 제작되는 폴리머 콘크리트 맨홀은 조기 고강도 발현, 접착성. 수밀성, 내동결융해성, 내약품성, 내마모성, 전기절연성이 우수하여 프리캐스트로 제작되는 많은 통신용 맨홀에 적용되고 있다. 폴리머 콘크리트의 결합재로 사용되는 불포화 폴리에스테르 수지는 열경화성수지로써, 자체 발열에 의해 거푸집을 탈형할 정도의 초기 경화 반응이 나타나지만, 구조물로서 요구되는 소요 강도를 발휘하기 위해서는 적정 온도에 의한 추가 양생이 반드시 필요하다. 이에 본 논문에서는 폴리머 콘크리트의 휨 강도 시험용 공시체를 사용하여, 다양한 양생 온도 조건 및 양생기간에 따른 휨 강도를 측정하였으며, 이를 가열 촉진 양생에 의한 휨 강도와 비교하여 콘크리트가 소요 강도를 발휘하는데 요구되는 적정 온도와 기간을 도출하였다. 이를 통해 폴리머 큰크리트 맨홀의 품질 확보를 위한 생산 관리와 제품 검사를 체계적이고 효율적으로 수행할 수 있도록 하였다.

  • PDF

Experimental Study on the Pore Clogging Phenomenon of Porous Concrete (투수콘크리트의 공극막힘현상에 대한 실험적 연구)

  • Nam, Jung-Man;Yun, Jung-Mann;Kim, Seung-Hyun;Song, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.577-584
    • /
    • 2011
  • A series of field and laboratory permeability tests were performed to investigate the pore-clogging phenomenon of porous concrete used for pavement materials of a road. The field permeability tests were conducted for 37 study points in Jeju city, using the porous concretes with 13mm of maximum coarse aggregate ($G_{max}$). The results show that the service life of porous concrete is about 22 months when the permeability of the porous concrete is designed for 0.01 cm/sec. Some specimens were made with the purpose of recreating pore-clogging phenomenon. Tests were done for injected concentration of pore-clogging materials or size of maximum coarse aggregates ($G_{max}$). The test results demonstrated that relatively long in service life experienced with small amount of injected concentration of pore-clogging materials, whereas relatively short in service life experienced with a reduction in size of maximum coarse aggregates ($G_{max}$). In conclusion, the service life of porous concrete is in proportion to the concentration of pore-clogging material but it is in inverse proportion to the size of maximum coarse aggregate ($G_{max}$). Thus, the persisting period of porous concrete can be determined with respect to concentration of pore-clogging materials or size of maximum coarse aggregates ($G_{max}$).