• Title/Summary/Keyword: 계측항목

Search Result 313, Processing Time 0.024 seconds

CEPHALOMETRIC ANALYSIS OF UPPER AND LOWER INCISORS IN DIFFERENTIAL FACIOSKELETAL PATTERN (악골형태에 따른 상하악절치위치에 관한 측모 두부방사선 계측학적 분석)

  • Kim, Jung-Ho;Kwon, Oh-Won;Kim, Jung-Min
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.735-753
    • /
    • 1992
  • The purpose of this study was to analyze the positions of upper and lower incisors according to facioskeletal patterns. The lateral cephalometric radiographs of sixty persons with normal occlusion, forty persons with Class II Division 1 malocclusion, and forty persons with Class III malocclusion all above the age of 18, were analyzed. The following results were obtained. 1. C I angle, the measurement related to masticatory system, were $89.20{\pm}4.34^{\circ}$ in normal occlusion group, $81.68{\pm}士5.95^{\circ}$ in Class II Division 1 malocclusion group and $101.96{\pm}6.31^{\circ}$ in Class III malocclusion group. 2. In comparison with the positions of upper and lower incisors according to facioskeletal patterns, Class II Division 1 malocclusion group showed that upper incisors were different significantly in all measurements and inclined labially (P < 0.05). Lower incisors were different significantly in all measurements except LI-APog, LI-APog (mm), LI-AB, LI-AB (mm) and inclined labially (P < 0.05), Class III malocclusion group showed that upper incisors were different significantly in all measurements except UI-SN, UI-OP, and inclined labially (P < 0.05). Lower incisors were different significantly in all measurements and inclined lingually (P < 0.05). 3. In all facioakeletal patterns, LI-SN and LI-PH ware correlated moderately to facioskeletal measurements, and FMA was correlated moderately to measurements of lower incisor position. 4. Regardless of the facioskeletal patterns, the reference planes equally applicable were AB line in the measurements of upper incisor and APog line in the measurements of lower incisor.

  • PDF

COMPARATIVE STUDY ON THE HORIZOTAL MEASUREMENTS OF SKELETAL CLASS III MALOCCLUSION USING THE ROC ANALYSIS (ROC 분석을 이용한 골격성 III급 부정교합의 수평계측방법간 비교연구)

  • Choi, Hee-Young;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.153-163
    • /
    • 1995
  • In this study, Receiver Operating Characteristic(ROC) analysis was used to evaluate the ability of cephalometric measurements to identify patients with Class III malocclusions. ROC analysis is the method for determining the validity of a diagnostic measure and for evaluating the relative value of diagnostic tests. The sample consisted of 496 patients with malocclusion. Class III malocclusion is defined as the dental relationship for which The mesiobuccal groove of the lower first molar is deviated mesially from the mesiobuccal cusp of the upper first molar. Of the total sample of 496 patients, 245 had Class III malocclusions. 16 cephalometric measurements were selected, each of which was treated as a diagnostic test. The ROC curves were generated for each cephalometric measurement with intervals of $1.0^{\circ}$ for angular measurements, 1.0mm for linear measurements. The area under the ROC curves was measured for direct comparison among different diagnostic tests. The results were as follows; 1. The 'Wits' appraisal was found to be a better diagnostic criterion for the presence of Class III malocclusion than any other commonly'used cephalometric measurement. 2. AB plane angle, ANB angle, App-Bpp distance, AF-BF distance, APDI, Distance of point A and Pog to N perpendicular, maxillomandibular differential had high diagnostic value. 3. Cephalometric measurements which evaluate the position of the mandible had moderate diagnostic value. 4. Cephalometric measurements related to the maxilla discriminated least between patients with and without Class III malocclusion.

  • PDF

Reproducibility of asymmetry measurements of the mandible in three-dimensional CT imaging (전산화단층사진을 이용한 하악골 3차원 영상에서 비대칭진단 계측항목의 재현도에 관한 연구)

  • Kim, Go-Woon;Kim, Jae-Hyung;Lee, Ki-Heon;Bwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.314-327
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the reproducibility of measurements representing asymmetry of the mandible and to identify which landmarks would be more useful in 3-dimensional (3D) CT imaging. Methods: Facial CT images were obtained from forty normal occlusion individuals. Eighteen landmarks were established from the condyle, gonion, and menton areas, and 25 measurements were constructed to represent asymmetry of the mandible; 8 for ramus length, 12 for mandibular body length, 1 for condylar neck length, 2 for frontal ramal inclination, and 2 for lateral ramal inclination. Inter- and intra-examiner reproducibility of the measurements was evaluated. Results: Inter-examiner reproducibility of the measurements proved to be high except for 3 measurements. Intra-examiner reproducibility also proved to be high except for 2 measurements. Inter- and intra-examiner reproducibility of the measurements including Gonion proved to be low. Conclusions: The results of the present study indicate that the landmarks and measurements constructed in 3D CT images can be used for the diagnosis of facial asymmetry.

CEPHALOMETRIC NORMS FOR ORTHOGNATHIC SURGERY (외과적 악교정술을 위한 두부방사선학 계측 기준치)

  • Sung, Jung-Ok;Kyung, Hee-Moon;Kwon, Oh-Won;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.169-185
    • /
    • 1989
  • The purpose of this study was to establish Korean norms that will be valuable aids for diagnosis in orthognathic surgery patients. Lateral cephalometric measurements were established for adult Koreans (60 males, 62 females) with normal occlusion and acceptable profiles. The results were as follows: 1. Means, standard deviation and sexual differentiation were included within each measurement. 2. In skeletal measurements, FH to SN and SN to mandibular plane measurements in females were larger than those in males while all linear measurements in males were larger than those in males were larger than those in females. 3. Significant differences were observed between male and female groups on all of the items that showed vertical relationship in dental measurements. And the measurements of ADH, PDH and overbite in males were larger than those in females while the measurements of incisor exposure in females were larger than those in males. 4. In all measurements of soft tissue except NLA, that is, of FCA, UFH, ULL and LLL, males were larger than those in females.

  • PDF

Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography (안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이)

  • Kim, Wang-Sik;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.163-173
    • /
    • 2005
  • The purpose of this study was to compare the asymmetric degree between maxillofacial hard and soft tissues in individuals with facial asymmetry. Computerized tomographies (CT) of 34 adults (17 male, 17 female) who had facial asymmetry were taken. The CT images were transmitted to personal computers and then reconstructed into three-dimensional (3D) images through the use of computer software. In order to evaluate the degree of facial asymmetry, 6 measurements were constructed as the hard tissue measurements while 6 counterpart measurements were taken as the soft tissue measurements. The means and standard deviations were obtained for each measurement using 3D measure, then t-test was used to investigate the differences between each hard tissue measurement and the corresponding soft tissue measurement All measurements used in the present study showed statistically significant differences between the hard and soft tissues. The degree of soft tissue asymmetry was smaller than that of corresponding hard tissue asymmetry in case of chin deviation, frontal ramal inclination difference, and frontal corpus inclination difference. On the other hand, the degree of soft tissue asymmetry was greater than that of underlying hard tissue asymmetry in the measurement of lip canting and lip cheilion height difference The present study suggests that asymmetric differences of hard and soft tissue is observed nu facial asymmetric subjects and thus soft tissue analysis is needed in addition to hard tissue analysis when making an evaluation of facial asymmetry.

Effects of vertical head rotation on the posteroanterior cephalometric measurements (정모두부방사선사진 촬영시 두부의 수직회전에 따른 투사오차)

  • Koh, Eun-Hee;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.73-84
    • /
    • 2003
  • This study was performed to find out how much projection errors in the cephalometric measurements were made by vertical head rotation in taking posteroanterior cephalograms. 25 adults without any apparent facial asymmetry or severe sagittal skeletal discrepancy were selected and the posteroanterior cephalograms were taken with the head rotated $5^{\circ},\;10^{\circ}$ superior and inferior each to the reference $position(0^{\circ})$. The 7 height, 5 width and 6 angular measurements were taken at each 5 positions. Through the statistical analysis of all measurements taken at each rotated position, folowing results were obtained.1. The projection errors of height measurements were remarkably target than those of width or angular measure nents. f. Among the height measurements, the farther to the rotation axis the measurements were, the larger the projection errors were. 3. Among the width measurements, mandibular width and mandibular width of mandibular first molars showed significant differences between the values taken at each rotated position, while nasal width, maxillary width and intermolar width of maxillary first molars did not. 4. Among the angular measurements, the angle between horizontal reference line and the line that is connected to crista galli and antegonion or maxillare showed significant differences between the values taken at each rotated Position. The above results suggest that it is needed to the effort to keep constant head position for taking the useful posteroanterior cephalogra, because projection errors are caused by vertical head rotation.

A Measurement Method for 3D Human Body Using 2D Images (2D 영상을 이용한 3D 인체 계측 방법)

  • 김창우;최창석;김효숙;강인애
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.201-204
    • /
    • 2001
  • 디지털 카메라를 이용하여 인체의 영상을 촬영하여 3D 인체를 계측하는 영상 계측 방법을 제안한다. 영상 계측을 위해 인체 촬영 환경을 설정하고, 정면, 측면, 후면의 인체 2D 영상을 촬영하여 사영투영을 고려하여 3D 인체를 추정하는 알고리즘을 개발한다. 인체 계측의 항목 중 40항목에 대해 직접 계측, 영상 계측, 3D 계측을 3인이 교대로 시행한 결과를 비교하고 있다. 계측자별, 계측 방법별로 비교할 때, 영상 계측은 최대오차 0.44cm로 3D 계측(허용오차 0.5cm)와 유사하여, 직접 계측에 비해 우수한 성능을 나타내고 있다. 이것은 영상 계측에서 사영투영을 이용하여 인체의 3D위치를 추정하여 계측 결과를 보정하고 있기 때문이다. 또한, 계측치 이외에 계측 장비, 비용, 기동성, 인력 부담등 여러 가지면 에서도 영상 계측은 장점을 고루 갖춘 방법으로 인체 계측에 사용할 수 있는 새로운 방법으로 기대된다.

  • PDF

Comparison of Anthropometric Measurements of Oriental and Caucasian Females for Sizing Systems (동양과 서양여자의 인체계측에 의한 치수의 비교)

  • Hu Kap-Sum
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.3
    • /
    • pp.1-7
    • /
    • 1985
  • 연구의 목적은 의류생산에 있어서 동양(Oriental women)과 서양여자(Caucasian women: U.S.A)의 인체계측에 의한 치수의 비교를 하였다. 연구자료는 동양여자 100명과 서양여자 970명의 자료로 비교하였다. 동양여자의 인체계측치는 1981년 4월 일본에서 필자에 의해 수집되고 서양여자의 인체계측치는 1976년 11월부터 1977년 2월 미국(U.S.A by the Quartermaster Corps of the United States Army)에서 인체계측을 한 자료이다. 동양과 서양여자의 인체계측치 중에서 각각 32항목을 선출하여 비교된 것은 높이항목과 길이항목(height-related measurements; height and length), 나비항특(surface measurements; breadth and depth) , 둘레항목(measurement of circumference)이다. 32항목을 평균치의 t-test로 동양인과 서양인을 비교한 결과, 모든 항목에서 P<.001 수준에서 유의한 차를 보였다. 그 중에서 머리둘레, 목둘레, 손목둘레, 팔굼치둘레, 손바닥둘레의 항목에서는 동양인이 서양인에 비해서 큰 값을 나타냈다. 그 외에 27개 항목은 동양인이 전부 높거나, 길거나, 또는 큰 값을 나타냈다. 표준편차에서 보이는 바와 같이 서양인자가 동양여자보다 크고, 특히 높이 항목, 길이항목(height-related measurements)이 더 높거나 길다. 이러한 결과로서 동양과 서양여자의 인종적인 측면에서, 다양한 의류생산에 있어서 고려해야 할 것 같다. 이 동양과 서양여자의 인체계측비교에 중요한 요점을 두고 연구한 것은 의류생산과정에 있어서, size설정, 보다 미적인 design, 의복구성을 위한 등등에 고려되겠으나, 특히 미국과 같은 대량생산국에서 동양과의 무역(import or export)에 있어서 중요하게 고려가 될것이며, 나날이 발전하는 우리나라의 의류무역에도 고려되리라 본다. 뒤에 recommendations for future research에서 말한 바와 같이 서양과 한국여자의 입체계측비교를 하며 우리나라의 의류무역(수출)에 도움이 되었으면 한다.

  • PDF

The Study for Establishing the Criteria of Measurement Items in the Monitoring System for the Steel-Box Girder Bridge by FEM Analysis (구조해석에 의한 강상자형교 상시계측시스템 계측항목별 관리기준치 설정 연구)

  • Joo, Bong-Chul;Park, Ki-Tae;You, Young-Jun;Lee, Chin-Hyung;Hwang, Yoon-Koog
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.35-41
    • /
    • 2009
  • If any bridge has the monitoring system, the bridge manager can check the history of bridge behavior and the progress of the damage more exactly. When the unexpected event (ex: earthquake and flood) happens, the manager can check the safety condition of the bridge and make the pertinent action for bridge management which is reduction of vehicle speed or traffic control through the system. Additionary the manager can make the well-timed repair or reinforcement through the system, so he can save the management cost or the life cycle cost. This study presents the method of setting the criteria by FEM analysis in bridge monitoring system, and the standard progress for setting the criteria about measurement items of monitoring system for the steel box type bridge.

  • PDF

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF