• Title/Summary/Keyword: 감마 지수

Search Result 82, Processing Time 0.026 seconds

The relative risk of major risk factors of ischemic heart disease (주요 위험요인별 허혈성심질환 사망위험도 분석)

  • Ko, Min-Jung;Han, Jun-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.2
    • /
    • pp.201-209
    • /
    • 2010
  • Due to the dramatic increase of mortality from ischemic heart disease (IHD) during the last decade, it is highly warranted to present the effective prevention strategy. Therefore this study identified the major risk factors of IHD over 10 years of follow-up among 2,268,018 participants of National Health Insurance Exam in 1996 with Cox proportional hazard model. In men, BMI, blood pressure, smoking were significantly associated with IHD, whereas hypertension, perceived health status and ${\gamma}$-GTP were related with IHD in women.

A Study on The Real-time Prediction of Traffic Flow in ATM Network (ATM망에서의 실시간 통화유랑 예측에 관한 연구)

  • Kim, Yun-Seok;Chin, Yong-Ohk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.10
    • /
    • pp.3195-3200
    • /
    • 2000
  • this paper is a stucy onthe preductionof multi-media traffic flow for the realizationof optimum ATM congestion control. In ATM network it is expected that the characteristic of multi-media traffic flow is varied slowly with a time. Fjor the simulation, time-variable multi-media traffic is penerated using possion distribution(connect calls per process time).\, gamma distribution(transmission rate per a call) and exponential distribution(holding time per a call). And using back-propagation neural netwok and proposed tripple neural network, the simulation to predict generaed traffic is executed. From the result,it's capability is shown that the proposed neural network model can be used in the predictionof ATM traffic flow.

  • PDF

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

4-Dimensional dose evaluation using deformable image registration in respiratory gated radiotherapy for lung cancer (폐암의 호흡동조방사선치료 시 변형영상정합을 이용한 4차원 선량평가)

  • Um, Ki Cheon;Yoo, Soon Mi;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.83-95
    • /
    • 2018
  • Purpose : After planning the Respiratory Gated Radiotherapy for Lung cancer, the movement and volume change of sparing normal structures nearby target are not often considered during dose evaluation. This study carried out 4-D dose evaluation which reflects the movement of normal structures at certain phase of Respiratory Gated Radiotherapy, by using Deformable Image Registration that is well used for Adaptive Radiotherapy. Moreover, the study discussed the need of analysis and established some recommendations, regarding the normal structures's movement and volume change due to Patient's breathing pattern during evaluation of treatment plans. Materials and methods : The subjects were taken from 10 lung cancer patients who received Respiratory Gated Radiotherapy. Using Eclipse(Ver 13.6 Varian, USA), the structures seen in the top phase of CT image was equally set via Propagation or Segmentation Wizard menu, and the structure's movement and volume were analyzed by Center-to Center method. Also, image from each phase and the dose distribution were deformed into top phase CT image, for 4-dimensional dose evaluation, via VELOCITY Program. Also, Using $QUASAR^{TM}$ Phantom(Modus Medical Devices) and $GAFCHROMIC^{TM}$ EBT3 Film(Ashland, USA), verification carried out 4-D dose distribution for 4-D gamma pass rate. Result : The movement of the Inspiration and expiration phase was the most significant in axial direction of right lung, as $0.989{\pm}0.34cm$, and was the least significant in lateral direction of spinal cord, as -0.001 cm. The volume of right lung showed the greatest rate of change as 33.5 %. The maximal and minimal difference in PTV Conformity Index and Homogeneity Index between 3-dimensional dose evaluation and 4-dimensional dose evaluation, was 0.076, 0.021 and 0.011, 0.0 respectfully. The difference of 0.0045~2.76 % was determined in normal structures, using 4-D dose evaluation. 4-D gamma pass rate of every patients passed reference of 95 % gamma pass rate. Conclusion : PTV Conformity Index was more significant in all patients using 4-D dose evaluation, but no significant difference was observed between two dose evaluations for Homogeneity Index. 4-D dose distribution was shown more homogeneous dose compared to 3D dose distribution, by considering the movement from breathing which helps to fill out the PTV margin area. There was difference of 0.004~2.76 % in 4D evaluation of normal structure, and there was significant difference between two evaluation methods in all normal structures, except spinal cord. This study shows that normal structures could be underestimated by 3-D dose evaluation. Therefore, 4-D dose evaluation with Deformable Image Registration will be considered when the dose change is expected in normal structures due to patient's breathing pattern. 4-D dose evaluation with Deformable Image Registration is considered to be a more realistic dose evaluation method by reflecting the movement of normal structures from patient's breathing pattern.

  • PDF

고강도 GA(Galvanized Annealing)재의 표면특성과 내식성간 상관성 분석

  • Jeong, Bong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.125-125
    • /
    • 2017
  • 최근 들어 내수용 및 수출용 자동차 보증 제도를 살펴보면 부품에 대한 방식 보증기간이 점차 연장되는 추세이며, 이에 따라 자동차사에서 요구하는 방식 및 내식성 평가 기준이 상향되어 가고 있다. 실제로 수출차에 대한 방청 품질 보증기간이 차체 구멍 발청 10년에서 12년으로 연장할 움직임을 보이는 등 점차 방식에 대한 관심이 높아지고 있다. 따라서 내식성 향상에 대한 끊임없는 연구가 지속적으로 이루어지고 있으며, 내식성 향상을 위해 구조/형상 변화, 도장 품질 향상, 최적화 설계 등 다방면에서 노력을 기울이고 있다. 그 중에서도 가장 근본적인 해결책인 소재의 내식성 향상에 대한 관심은 날로 높아지고 있는 실정이다. 특히 일본 등지에서는 GA 도금재의 사용이 증가하고 있으나, 아직은 내식성에 대한 효율적이고 체계적인 관리가 부족한 면이 있다. GA재는 합금화 과정에서 야기되는 Fe% 합금화도, 합금화 상분율(감마, 델타, 제타상), crater 등 복잡한 소재의 특성으로 인해 소재의 내식성 분석에 고려할 사항이 많다. 실제 여러 실험들을 통해서 GA재가 내식성에 영향이 있는 인자들에 대해 많은 연구가 진행되었지만 명확히 정량화되어 있지 않은 관계로 GA재의 내식성 관리 기준에 대해서도 명확하진 않은 상황이다. 본 연구에서는 당사재와 타사재의 고강도 GA재 (>440 MPa) 11종에 대해 crater분율, zeta상, 합금화도, 도금량 등의 다양한 도금 물성들을 조사하였다. 또한 이 시편들을 34일 동안의 복합염수 분무법(CCT)을 통해 얻은 최대 및 평균 블리스터 폭과 소재 표면품질 물성과의 상관관계를 통해서 부식과 연관된 관련인자들을 도출하고 정량적인 관계를 살펴보았다. GA재의 경우 다양한 물성들 중에서 도금 크레이터, 제타상, 합금화도 순으로 내식성에 영향을 주는 것으로 확인이 되었으며 이 세 인자들을 내식성 평가 지수화하여 GA재 생산시 효율적인 관리범위를 지정하는데 이용 가능할 수 있도록 diagram을 도출하였다. 따라서, 본 연구를 통하여 자동차사에서 요구하는 내식성 기준을 만족하기 위한 내식성 상관 인자들의 관리 수준을 정량화함으로써 보다 우수한 소재의 관리를 할 수 있도록 하고자 한다.

  • PDF

Organ Dose Assessment of Nuclear Medicine Practitioners Using L-Block Shielding Device for Handling Diagnostic Radioisotopes (진단용 방사성동위원소 취급 시 L-block 차폐기구 사용에 따른 핵의학 종사자의 장기 선량평가)

  • Kang, Se-Sik;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • In the case of nuclear medicine practitioners in medical institutions, a wide range of exposure dose to individual workers can be found, depending on the type of source, the amount of radioactivity, and the use of shielding devices in handling radioactive isotopes. In this regard, this study evaluated the organ dose on practitioners as well as the dose reduction effect of the L-block shielding device in handling the diagnostic radiation source through the simulation based on the Monte Carlo method. As a result, the distribution of organ dose was found to be higher as the position of the radiation source was closer to the handling position of a practitioner, and the effective dose distribution was different according to the ICRP tissue weight. Furthermore, the dose reduction effect according to the L-block thickness tended to decrease, which showed the exponential distribution, as the shielding thickness increased. The dose reduction effect according to each radiation source showed a low shielding effect in proportion to the emitted gamma ray energy level.

Prevalence and Associated Factors of Gallbladder Polyps Among Residents of Jeju City and Seogwipo City on Jeju Island, Korea, Far from the Korean Peninsula (한반도에서 멀리 떨어진 제주도의 제주시와 서귀포시 거주민들간의 담낭용종 유병률과 위험인자)

  • Kwon, Oh-Sung;Yang, Jin-Soo;Kim, Young-Kyu;Jung, Jin-Young
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.155-157
    • /
    • 2022
  • 담낭용종은 담낭암의 원인일 수 있다. 담낭용종의 잘 알려진 위험요소는 대사증후군, 젊은 나이, 이상지질혈증 등이다. 제주도는 한반도에서 약 80km 떨어져 있으며 한라산을 중심으로 두 개의 행정구역(제주시와 서귀포시)으로 나뉘어 있다. 국제공항과 국제항구는 유일하게 제주시에만 위치해 있다. 또한 제주시에는 서귀포시보다 기업체와 학교의 수가 더 많다. 식이 및 알코올 소비는 두 지역 간에 다르며 이러한 요인이 담낭용종 유병률에 영향을 미칠 것이다. 따라서 이 연구의 목적은 두 지역 거주민들의 담낭용종 유병률을 조사하고 담낭용종과 관련된 다양한 요인들을 비교해보고자 하였다. 본 연구는 2009년 1월부터 2019년 12월까지 제주대학교병원 단일 건강검진센터를 방문한 21,734명을 대상으로 하였다. 담낭용종 유병률과 관련된 요인을 제주시 거주민과 서귀포시 거주민 두 집단으로 나누어 조사하였다. 담낭용종 유병률은 제주시가 10.1%, 서귀포시가 9.2% (P = 0.039)였다. 평균 연령과 고위험 음주자의 비율은 서귀포시에서 더 높았다. 평균 체질량지수와 공복혈당, 총콜레스테롤, 저밀도지질단백질-콜레스테롤, 아스파르테이트아미노전이효소, 감마-글루타밀전이효소, 알칼리인산분해효소 수치는 제주시에서 낮게 나타났다. 이 연구에서 담낭용종 유병률은 제주도의 두 지역 간에 유의한 차이가 있었다. 연령과 알코올 소비는 이러한 차이에 기여하는 주요 요인이 될 수 있다.

  • PDF

Evaluation of Validity Glomerular Filtration Rate Measured by Gates Method according Region of Interest (관심 영역 설정에 따른 Gates법 토리여과율의 유효성 평가)

  • Su-Young Park;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.417-425
    • /
    • 2023
  • The glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0~1 minutes, Gates-2: 1~3 minutes, Gates-3: 3~27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2~3 minutes is calculated can aid in accurately determining GFR when Gates Method.

Evaluation of Droughts in Seoul Using Two-Dimensional Drought Frequency Analysis (이차원 가뭄빈도해석을 통한 서울지역의 가뭄 평가)

  • Yeon, Je-Mun;Byun, Sung-Ho;Lee, Jung-Kyu;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.4
    • /
    • pp.335-343
    • /
    • 2007
  • Drought characteristics need to be preceded before establishing a drought mitigation plan. In this study, using a Standardized Precipitation Index (SPI), a hydrologic drought was defined as an event during which the SPIs are continuously below a certain truncation level. Then, a methodology of drought frequency analysis was performed to quantitatively characterize droughts considering drought duration and severity simultaneously. The theory of runs was used to model drought recurrence and to determine drought properties like duration and severity. Short historical records usually do not allow reliable bivariate analyses. However, more than hundred years of precipitation data (1770 ${\sim}$ 1907) collected in Chosun Kingdom Age using an old Korean rain gage called Chukwooki can provide valuable information about past events. It is shown that a bivariate gamma distribution well represented the joint probabilistic properties of Korean drought duration and severity. The overall results of this study show that the proposed bivariate drought frequency analysis overcomes the drawbacks of the conventional univariate frequency analysis by providing a consistent representation of the drought recurrent property.