• Title/Summary/Keyword: [BQ] method

Search Result 104, Processing Time 0.036 seconds

A Study of the Rn-222 and Ra-226 Analysis in Aqueous Samples with a Low-Level Liquid Scintillation Counter and Pulse-Shape Analysis (저준위 액체섬광계수기와 파형분석법을 이용한 수용액 중 라돈-222 및 라듐-226의 분석법 연구)

  • Shin, Hyun-Sang;Lee, Chang-Woo;Lee, Myung-Ho;Cho, Yung-Hyun;Hong, Kwang-Hee;Choi, Geun-Sik
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.428-435
    • /
    • 1999
  • A method for measuring Rn-222 and Ra-226 in aqueous sample using liquid scintillation counting technique has been studied. The Rn-222 was extracted easily from the water sample (10 mL) by 12 mL of xylene based organic scintillant. After radioactive equilibrium between Rn-222 and its alpha emitting decay products for three hours, the alpha activity from Rn-222 and its decay products were measured in a scintillation vial using the Wallae $1220^{TM}$ Quantulus liquid scintillation counter. Ra-226 concentration in aqueous sample was determined, after isolation of Ra-226 from the sample matrix, by extraction the ingrowth of the Rn-222 and its alpha emitting decay products with xylene based organic scintillant. The optimum pulse-shape analysis (PSA) value was evaluated by the figure of merit (FM) criterion. Minimum detectable activity (MDA) is about 0.14 Bq/L (3.78 pCi) for the region of Rn-222 and its alpha emitting decay products and 0.06 Bq/L (1.63 pCi) for the region of Po-214 respectively, with 200 min, counting time at PSA level 100 in the low-diffusion polyethylene vial and xylene based cocktail solution. Experiment on the optimum sample-cocktail volume ratio, the influence of agitation and the diffusion of radon from vial were carried out.

  • PDF

A study on the Prediction of Indoor Concentration due to Radon Exhalation from Domestic Building Materials (건축자재 라돈 방출에 의한 실내공기 중 라돈농도 예측에 관한 연구)

  • Lee, Cheolmin;Gwak, Yoonkyung;Lee, Donghyun;Lee, Dajeong;Cho, Yongseok
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1131-1138
    • /
    • 2015
  • Radon exhalation rates have been determined for samples of concrete, gypsum board, marble, and tile among building materials that are used in domestic construction environment. Radon emanation was measured using the closed chamber method based on CR-39 nuclear track detectors. The radon concentrations in apartments of 100 households in Seoul, Busan and Gyeonggi Provinces were measured to verify the prediction model of indoor radon concentration. The results obtained by the four samples showed the largest radon exhalation rate of $0.34314Bq/m^2{\cdot}h$ for sample concrete. The radon concentration contribution to indoor radon in the house due to exhalation from the concrete was $31.006{\pm}7.529Bq/m^3$. The difference between the prediction concentration and actual measured concentration was believed to be due to the uncertainty resulting from the model implementation.

POSITIVE SOLUTION FOR A CLASS OF NONLOCAL ELLIPTIC SYSTEM WITH MULTIPLE PARAMETERS AND SINGULAR WEIGHTS

  • AFROUZI, G.A.;ZAHMATKESH, H.
    • Journal of applied mathematics & informatics
    • /
    • v.35 no.1_2
    • /
    • pp.121-130
    • /
    • 2017
  • This study is concerned with the existence of positive solution for the following nonlinear elliptic system $$\{-M_1(\int_{\Omega}{\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^pdx)div({\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^{p-2}{\nabla}u)\\{\hfill{120}}={\mid}x{\mid}^{-(a+1)p+c_1}\({\alpha}_1A_1(x)f(v)+{\beta}_1B_1(x)h(u)\),\;x{\in}{\Omega},\\-M_2(\int_{\Omega}{\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^qdx)div({\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^{q-2}{\nabla}v)\\{\hfill{120}}={\mid}x{\mid}^{-(b+1)q+c_2}\({\alpha}_2A_2(x)g(u)+{\beta}_2B_2(x)k(v)\),\;x{\in}{\Omega},\\{u=v=0,\;x{\in}{\partial}{\Omega},$$ where ${\Omega}$ is a bounded smooth domain of ${\mathbb{R}}^N$ with $0{\in}{\Omega}$, 1 < p, q < N, $0{\leq}a$ < $\frac{N-p}{p}$, $0{\leq}b$ < $\frac{N-q}{q}$ and ${\alpha}_i,{\beta}_i,c_i$ are positive parameters. Here $M_i,A_i,B_i,f,g,h,k$ are continuous functions and we discuss the existence of positive solution when they satisfy certain additional conditions. Our approach is based on the sub and super solutions method.

Health Effects and Social Benefit of Residential Radon Reduction (주택 라돈 저감의 건강 효과와 사회적 편익)

  • Yongjoo Kim
    • Environmental and Resource Economics Review
    • /
    • v.31 no.4
    • /
    • pp.505-529
    • /
    • 2022
  • Radon is a radioactive gas that causes lung cancer deaths. The contingent valuation method (CVM) is used to estimate the value of a statistical life(VSL) of 2.054 billion won for the death due to residential radon in Korea. Residential radon is assumed to have caused 2,330 deaths in 2020, of which the estimated social cost is 4.78 trillion won. When a national compulsory standard of 200Bq/m3 is set for residential radon concentration, the number of lives saved is estimated to be 691, leading to a social benefit of 1.42 billion won. This study reports the origin, characteristics and health risk of residential radon, and emphasizes the importance of a dramatic increase in the budget for residential radon reduction policies.

Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

  • Yoon, Yoon Yeol;Kim, Yongcheol
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.142-146
    • /
    • 2020
  • Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF

A Study on Artificial Radionuclides(134Cs, 137Cs and 239+240Pu) Distribution in the Sediment from Lake Euiam (의암호 퇴적물 내 인공방사성동위원소 (134Cs, 137Cs, 239+240Pu) 분포특성 연구)

  • Kim, Seung Hwan;Lee, Sang-Han;Oh, Jung Suk;Choi, Jong Ki;Kang, Tae Gu
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.223-230
    • /
    • 2015
  • The objective of this study is to identify the radionuclide distribution in public water by carrying out the analysis of artificial radionuclides($^{134}Cs$, $^{137}Cs$, $^{239+240}Pu$), natural radionuclide($^{210}Pb$) and TOC in the lake Euiam sediment in Chuncheon, South Korea. The $^{134}Cs$ concentration in all lake sediments showed below MDA values, and the $^{137}Cs$ concentration in lake sediment were ranged from MDA to $8.79Bq{\cdot}kg^{-1}-dry$. The $^{137}Cs$ concentrations in surface sediment were reported to be 2.4 to $4.2Bq{\cdot}kg^{-1}-dry$. The lowest concentration of $^{137}Cs$ was reported at St. 4 and the highest concentration was reported at St. 3, respectively. The $^{239+240}Pu$ concentration in lake sediment were ranged from 0.049 to $0.47Bq{\cdot}kg^{-1}-dry$. The lowest concentration was reported at St. 2 and the highest concentration was reported at St. 3. The correlation(r) between the $^{239+240}Pu$ concentration and $^{137}Cs$ concentration in lake sediment presented higher values (0.54 to 0.97) and this suggests the behavior and origin of $^{137}Cs$ is identical to the $^{239+240}Pu$ in the sediment. The $^{134}Cs$ concentration below MDA value and the $^{239+240}Pu/^{137}Cs$ ratio(mean value of 0.041) indicated that the artificial radionuclides in the sediment were originated from global fallout by the atmospheric testing of nuclear weapons conducted by former USSR and U.S.A, but not from the Fukushima Daiichi NPP accident. The sedimentation rate derived from $^{210}Pb$ age-dating method at St. 2 is calculated to be $0.31{\pm}0.06cm{\cdot}y^{-1}$. This value is similar to the value ($0.41{\pm}0.05cm{\cdot}y^{-1}$) estimated from the $^{137}Cs$ maximum peak produced from early 1960's. The content of TOC in lake Euiam sediments varied from 0.20 to 13.01%. While the highest correlation between TOC and $^{137}Cs$ concentration in the sediment were found at St. 1, the others presented the low correlation.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

A Case Study about Counting Uncertainty of Radioactive Iodine (131I) in Public Waters by Using Gamma Spectrometry (감마분광분석을 이용한 환경 중 방사성요오드(131I)의 측정 불확도에 관한 사례 연구)

  • Cho, Yoonhae;Seol, Bitna;Min, Kyoung Ok;Kim, Wan Suk;Lee, Junbae;Lee, Soohyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • The radioactive iodine ($^{131}I$) presents in the environment through the excrete process of nuclear medicine patients. In the detecting of low level of $^{131}I$ in the public water, the counting uncertainty has an effect on the accuracy and reliability of detecting $^{131}I$ radioactivity concentration. In this study, the contribution of sample amount, radioactivity concentration and counting time to the uncertainty was investigated in the case of public water sample. Sampling points are public water and the effluents of a sewage treatment plant at Sapkyocheon stream, Geumgang river. In each point, 1, 10 and 20 L of liquid samples were collected and prepared by evaporation method. The HPGe (High Purity Germanium) detector was used to detect and analyze emitted gamma-ray from samples. The radioactivity concentration of $^{131}I$ were in the range of 0.03 to 1.8 Bq/L. The comparison of the counting uncertainty of the sample amount, 1 L sample is unable to verify the existence of the $^{131}I$ under 0.5 Bq/L radioactivity concentration. Considering the short half-life of $^{131}I$ (8.03 days), a method for measuring 1 L sample was used. However comparing the detecting and preparing time of 1, 10 L respectively, detecting 10 L sample would be an appropriate method to distinguish $^{131}I$ concentration in the public water.