• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.024 seconds

Studies on the Preparation of $^{99m}TC$ Labelled Human Albumin Microsphere for Lung Scintigraphy (폐 신티그래피용 $^{99m}TC$ 표지 미소구형인 혈청 알부민의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 1989
  • In order to develop technetium-99m-labelled human albumin microsphere (HAM) for lung scintigraphy, various experimemts such as preparation and fractionation of HAM, establishment of optimal labelling conditions, determination of radiochemical purity, stability test and biodistribution of $^{99m}Tc-HAM$ were carried out. HAM was prepared from the suspension of 1ml aqueous human serum albumin (25%) in 130 ml of olive oil at $130\sim135^{\circ}$ with vigorous stirring. The resulting HAM was fractionated with microsieve to get the desired particle size $(15\sim50\mu)$ and autoclaved for sterilizaiton. The HAM particles were treated with stannous chloride and the pH of the suspension was adjusted to $3.0\sim3.5$ with phosphate buffer. After freeze-drying the contents of single reaction vial containing 5 mg of HAM and 0.2 mg of $SnCl_2$ it was reacted with $Na^{99m}TcO_4$. The labelling yield was higher than 99.5% and the stability of $^{99m}Tc-HAM$ was high enough to maintain 99.1% of radiochemical purity up to 24 hours. Lung and liver uptake in mice was found to be 94% and 0.9%, respectively. Excellent rabbit and human lung scans were also obtained.

  • PDF

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.

Performance Evaluation of Substitution Radiopharmaceutical according to Restriction of the Radiocolloids in Lymphoscintigraphy (Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가)

  • Seo, Young-Deok;Jeong, Jae-Hun;Moon, Jong-Woon;Yun, Sang-Hyeok;Kim, Yeong-Seok;Kang, Se-Hun;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • Purpose: Several radioactive agents were used for lymphoscintigraphy in breast cancer. But recently, due to the change of local radiopharmaceutical licensing policy and discontinuation of supplies from manufacturer, we could not use many radiocolloids such as $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin. So it is necessary to use the substitution radiopharmaceutical. Therefore, this study aims to evaluate the performance of substitution radiopharmaceutical ($^{99m}Tc$-Phytate) including the existing radiocolloids and to set up of the appropriate protocol in lymphoscintigraphy. Materials and Methods: For each radiocolloids ($^{99m}Tc$-Antimony Trisulfide Colloid (ASC), $^{99m}Tc$-Tin Colloid (TC), $^{99m}Tc$-Human Serum Albumin (HSA), $^{99m}Tc$-Phytate) were performed the particle size by Zeta Sizer (Nano-ZS) and we compared the radiolabeling time, procedure and acquisition time for each of the radiocolloids (total 200 patients). For the last time, we made an analysis of image for each of the radiocolloids with our previous report (SJ Jang et al, Korean Nucl Med Mol imaging Vol.41, No.6, Dec 2007). Results: The particle size of each radiocolloids showed A.S.C (50 nm), T.C (310 nm), H.S.A (10.8 nm), $^{99m}Tc$-Phytate (499 nm). The labeling and acquisition time for each of the radiocolloids showed no substantial difference. But there is difference of the labeling time for the A.S.C. because the ASC procedure need to boiling process. There were no significant differences among those radiocolloids (p>0.005) in the identification rate (IR), false negative rate (FNR), and negative predictive value (NPV). Conclusions: $^{99m}Tc$-labeled radiocolloids showed equivalent results in lymphoscintigraphy. Therefore, in this exam of each radiocolloids could be applied appropriate protocol in lymphoscintigraphy.

  • PDF

The development of a portable MO4- (M = 188Re or 99mTc) concentration device for extending the lifetime of RI generators

  • Choi, Kang-Hyuk;Park, Ul Jae;Kim, Jong Bum;Jang, Beom-Su
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.3-10
    • /
    • 2019
  • The activities per volume of $^{188}Re$ and $^{99m}Tc$ from their generators are dependent on the specific activity of their mother nuclides $^{188}W$ and $^{99}Mo$ respectively. After a particular lapse of time, the eluted RI activity is exponentially reduced and thus cannot satisfy the needs of clinical application. The purpose of this study is to develop a $^{188}Re$ and $^{99m}Tc$ concentration device with a compact size that can extend the period of use as well as conveniently concentrate the RI. We designed the concentration module by including two-different check valves that do not required any manual on-off operations. In these concentration process, cation exchange resin embedded with Ag and anion exchange resins were used. After completing the concentrating step, the recovering yield was identified to be more than 93% for $^{188}Re$ generators and 88% for $^{99m}Tc$ generators. Moreover, all these procedures were done within 5 min.

Assessment of Regional Myocardial Wall Motion by Gated $^{99m}Tc-MIBI$ Myocardial SPECT (게이트 $^{99m}Tc-MIBI$ 심근 SPECT의 심근 분절 운동 평가능력)

  • Kim, S.W.;Lee, D.S.;Kim, S.H.;Hyun, I.Y.;Chung, J.K.;Lee, M.M.;Lee, M.C.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.473-477
    • /
    • 1995
  • Information about regional wall motion obtained with gated $^{99m}Tc-MIBI$ SPECT was compared in 23 subjects(4 normals) to echocardiography or contrast left ventriculography. Gated SPECT study using 20-30 mCi $^{99m}Tc-MIBI$ were aquired lot 8 frames/RR interval (aqusition time=40min.) and processed with Cine Mode computer protocol. Regional wall motion was assessed by visual analysis. The concordance with echocardiography was 88% and with contrast ventriculography was 78%. We conclude that gated $^{99m}Tc-MIBI$ SPECT was effective in assessing the regional wall motion with the information of regional perfusion in one study.

  • PDF

Nuclear Imaging Evaluation of Galactosylation of Chitosan (핵의학 영상을 이용한 chitosan의 galactosylation 효과에 대한 평가)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Park, In-Kyu;Cho, Chong-Su;Kim, Chang-Guhn;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • Purpose: Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelator, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Methods and Materials: Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan. Cytotoxicity of $^{99m}Tc$-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with $^{99m}Tc$-GMC and $^{99m}Tc$-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. Results: The results of MTT assay indicated that $^{99m}Tc$-GMC was non-toxic. $^{99m}Tc$-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, $^{99m}Tc$-MC showed faint liver uptake. $^{99m}Tc$-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Conclusion: Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetabililty is a clear example of the great benefit proffered by nuclear imaging.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

Tc-99m Labeling of Dione Bisoxime Compounds (Dione Bisoxime 계통의 화합물에 대한 테크네슘표지 원리에 관한 연구)

  • Jeong, Jae-Min;Cho, Jung-Hyuk;Oh, Seung-Joon;Lee, Myung-Chul;Chung, Soo-Wook;Chung, June-Key;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.110-117
    • /
    • 1995
  • Tc-99m Labeled hexamethylenepropyleneamineoxime ([$^{99m}Tc$]-HMPAO) is a famous amino-oxime compound and is widely used to construct SPECT images of cerebral blood flow. To investigate the relationship between chemical structure and radiolabeling in these kind of diamine-oxime compounds, we synthesized seven compounds by Schiff's base formation and successive reduction with sodium borohydride. They were (RR/SS )-4,8-diaza-3,6,6,9-tetramethylundecane-2,10-dione bisoxime (2), (RR/SS/meso)-4,8-diaza-3,9-dimethy-lundecane-2,10-dione bisoxime (4), (RR/SS/meso)-4,8-diaza-3,10-dimethyldodecane-2,11-dione bisoxime (5), (RR/SS/meso)-4,7-diaza-3,6,6,8-tetramethyldecane-2,9-dione bisoxime (8), (RR/SS/meso)-4,7-diaza-5,6-cyclohexyl-3,8-dimethyldecane-2,9-dione bisoxime (10), (RR/SS/meso)-3,4-bis(1-aza-2-methyl-3-oxime-1-butyl)-benzoic acid (12), and (RR/SS/ meso)-2,3-bis(1-aza-2-methyl-3-oxime-1-butyl) benzophenone (14). Chemical structures of all the synthesized compounds were identified by taking $^1H$ spectrum. Among them, 2 and 4 are propyleneamine oxime (PnAO), 6 is butyleneamine oxime (BnAO) and 8, 10, 12 and 14 are ethyleneamine oxime (EnAO). Each compound (0.5 mg) was incubated with stannous chloride (0.5 g - 8 g), carbonate-bicarbonate buffer (final concentration = 0.1 M, pH 7 - pH 10) and Tc-99m-pertechenate (1 ml). Tc-99m labeling of these compounds were checked by ITLC (acetone), ITLC (normal saline), reverse phase TLC (50 % acetonitrile) and ITLC (ethyl acetate). According to the results, EnAO's were not labeled by Tc-99m in any of above condition. About 11 % of maximum labeling efficiency was obtained with BnAO. However, 4 (PnAO) was labeled with Tc-99m to 85 % which is similar to the labeling efficiency of 2 (HMPAO). Hydrophilic impurity (9 % ) was the most significant problem with the labeling of 4, however, pertechnetate (3 % ) and colloid (3 %) were minor problem. In conclusion, we synthesized seven diamine blsoxlme compounds. Among them, four EnAO compounds were not labeled by Tc-99m. A BnAO was labeled poorly and two PnAO's were labeled well. These labeling can be explained by tertiary structure of their Tc-99m chelate.

  • PDF

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

A Study on the Condition Analysis and Improvement of Domestic Medical 99Mo/99mTc Generators Self-disposal (국내 의료용 99Mo/99mTc Generator 자체 처분 지침 현황 분석 및 개선 방향에 대한 연구)

  • Ryu, Chan-Ju;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.297-303
    • /
    • 2019
  • The nuclear medicine department of a domestic medical institution uses $^{99m}TcI$, a radionuclide, from $^{99}Mo/^{99m}TcI$ Generator, to inject radioactive drugs into patients. Among the expired generators, imported from foreign countries, the medical institution implements its own disposal. Each medical institution shall satisfy the permitted in-house disposal concentration of radioactive wastes. The guidelines for self-disposal presented in Korea suggested that self-disposal can be performed 80 days after the generator is used. The purpose of these guidelines is to analyze them by comparing them with the data measured directly with the generator and to study if they are feasible. As a result, the generator with a capacity of 1,000 mCi has the longest half-life, and when tested with a high-radiation Mo(molybdenum) column, the number of days that are below the permitted concentration of body disposal with radioactive waste was 72 days and 71 days that were derived from direct column measurement. The results of the direct study confirmed that the guidelines for in-house disposal in Korea were reasonable, as there were 8 to 9 days of storage compared to the number of in-house disposal days provided in the guidelines.