Studies on the Preparation of $^{99m}TC$ Labelled Human Albumin Microsphere for Lung Scintigraphy

폐 신티그래피용 $^{99m}TC$ 표지 미소구형인 혈청 알부민의 제조에 관한 연구

  • Park, Kyung-Bae (Department, Korea Advanced Energy Research Institute) ;
  • Awh, Ok-Doo (Department, Korea Advanced Energy Research Institute) ;
  • Kim, Jae-Rok (Department, Korea Advanced Energy Research Institute)
  • 박경배 (한국에너지연구소 원자로동위원소실) ;
  • 오옥두 (한국에너지연구소 원자로동위원소실) ;
  • 김재록 (한국에너지연구소 원자로동위원소실)
  • Published : 1989.05.31

Abstract

In order to develop technetium-99m-labelled human albumin microsphere (HAM) for lung scintigraphy, various experimemts such as preparation and fractionation of HAM, establishment of optimal labelling conditions, determination of radiochemical purity, stability test and biodistribution of $^{99m}Tc-HAM$ were carried out. HAM was prepared from the suspension of 1ml aqueous human serum albumin (25%) in 130 ml of olive oil at $130\sim135^{\circ}$ with vigorous stirring. The resulting HAM was fractionated with microsieve to get the desired particle size $(15\sim50\mu)$ and autoclaved for sterilizaiton. The HAM particles were treated with stannous chloride and the pH of the suspension was adjusted to $3.0\sim3.5$ with phosphate buffer. After freeze-drying the contents of single reaction vial containing 5 mg of HAM and 0.2 mg of $SnCl_2$ it was reacted with $Na^{99m}TcO_4$. The labelling yield was higher than 99.5% and the stability of $^{99m}Tc-HAM$ was high enough to maintain 99.1% of radiochemical purity up to 24 hours. Lung and liver uptake in mice was found to be 94% and 0.9%, respectively. Excellent rabbit and human lung scans were also obtained.

Keywords