Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference (한국조명전기설비학회:학술대회논문집)
The Korean Institute of IIIuminating and Electrical Installation Engineers
- 기타
Domain
- Electricity/Electronics > Home/Electric Appliances
2003.11a
-
Platforms of many railroad stations are crowded with passengers regardless of the time throughout day. But the intensity of illumination of the existing lightening systems are so low enough to make passengers feel inconvenience in using platforms. Consequently there exists high possibility of accidents in platforms of low illumination. Hence, for the safety and convenience of passengers, it is necessary to improve the luminous intensity of lightening system for platforms. This paper points out the problems of existing system and presents the method to improve it.
-
경관 조명의 활성화에 따른 전반적인 흐름을 소개하고 이에 따른 경관 조명 알고리즘을 시작으로 객관적인 경관 조명 평가의 필요성을 제시하였다. 보다 객관적인 요소인 경제성 평가에 초점을 맞추어 실내조명과 옥외조명시스템을 공학적으로 비교 분석하였고 실내조명에서 적용되었던 경제성 평가법을 실외 조명용으로 재해석하여 구체적인 경관 조명 설계를 제시하였다. 또한 경관 조명에서의 공학적 접근과 설계를 접목한 평가를 통해 적절한 조명 시스템을 분별할 수 있도록 하였다.
-
무전극 형광램프는 발광하는 부분의 사이즈가 크고 광원의 특성상 점광원으로 볼 수 없기 때문에 효율적인 광학기구를 설계하기 어렵다. 특히 반사판 설계시 반사광이 램프로 재흡수 되는 것을 고려하여야 한다. 본 논문은 무전극 형광램프에 대하여 반사광이 램프로 재흡수 되는 것을 막고 효율을 높이며 목표배광에 맞출 수 있는 2차원 축대칭형 반사판 설계법을 제시하였다. 그리고 이 설계법의 문제점과 해결방법에 대하여 고찰하였다.
-
헤드램프는 안개등, 후미등, 제동등, 방향지시등과 함께 자동차의 등화장치 중의 하나로써 특히 야간의 안전운행을 위해 필수적인 장치이다. 야간 운전시 차량의 운전자는 마주오는 차량의 헤드램프에 의한 눈부심으로 도로의 사정을 정확히 파악할 수 없는 일이 종종 발생하게 되는데 이것은 야간 사고의 큰 원인으로 지목된다. 그러므로 헤드램프의 빔패턴은 정확하고 sharp한 cut-off line을 가져야 한다. 본 논문에서는 미국식 빔패턴(SAE type)을 고려한 헤드램프용 반사갓 설계의 한가지 알고리즘을 제시한다.
-
As we know, topography of korea is composed of many mountains Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program).
-
This paper presents a microprocessor controlled digital ballast for HID lamps, which gives intelligent features such as a precise power control, optimum ignition voltage and detection of end of life. Average current mode PFC is employed for reducing EMI and a universal input. Direct spread spectrum is done by applying 1 KHz triangular wave for removing acoustic resonance. This frequency modulation of 1 KHz gives also low EMI level and no ripple on lamp current. The microprocessor controls the voltage of DC-bus, the voltage of ignition pulses, the power of output and the bandwidth of spread spectrum. A 250W digital ballast is implemented with an efficiency of 93% and a maximum EMI level of 55 ㏈
${\mu}$ V. -
Development of light sources has been constantly grown after incandescent lamps had been invented by Thomas Edison. Recently, the eletrodeless lamp is introduced as a new light source of a high efficacy and long life. But, despite of such advantages, luminaires of electrodeless lamps are not widely used. It is necessary to develope the design of the luminaire together with light source development. In this paper, design algorithm of the luminaire that is adaptable to electrodeless lamp and use Genetic Algorithm as a optimization method to find luminous intensity distribution required is introduced.
-
축구 전용 경기장에서 캐노피에 설치되는 등기구의 위치를 Pattern Search법을 이용하여 컴퓨터 시뮬레이션하였다. 조명 등기구 배치간격을 변화시키는 시뮬레이션을 통해 국·내외(FIFA, 유럽방송연맹, KS) 기준에 명시된 수평면 조도, 수직면 조도, 균제도, 눈부심 정도에 적합한 최적의 값을 찾았었다. 향후 국내 축구 전용 경기장 조명기구의 설계 및 시공, 유지관리 보수시 많은 참고가 되었으면 한다.
-
본, 연구는 새로운 기체방전 AND gate를 AC 3전극 면방전 PDP에 적용하기 위한 AC-DC floating 방전을 사용한 어드레스 구동특성을 해석한 것이다. 실험결과 floating 방전을 이용하여 어드레스 방전을 개시시킬 수 있었으며 표시방전까지 용이하게 동작시킬 수가 있었다. 또한 floating 방전과 타이밍을 동기시켜 보조전극에 프라이밍 방전을 일으켜 줌으로써 floating 방전 공간에 공간전하를 충분히 공급해 줌으로써 데이터 전압을 100V 정도까지 낮출 수 있었으며 어드레스 동작 마진도 100V 정도까지 얻을 수가 있었다.
-
본 연구에서는 새로 고안된 DC방전 AND gate를 구성하는 각 방전셀 상호간의 영향을 방전특성 측면에서 규명하였다. 4개의 각 셀은 서로 공간전하와 결합하여 깊은 연관이 있었으며 그 결과 PDP의 address 방전을 도와주기 위한 프라이밍 방전의 동작마진을 얻기가 매우 어렵다는 것을 정성적으로 알았다. 실험결과 각 전극의 최적화된 방전전압을 결정할 수 있었다.
-
Recently, a fuel cell is remarkable for new generation system. The fuel cell generation system converts the chemical energy of a fuel directly into electrical energy. The fuel cell generation is characterized by low voltage and high current. For connecting to general load, it needs both a step up converter and an inverter. The step up converter makes DC to DC and the inverter changes DC to AC. In this paper, full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experimental results are displayed under several load conditions.
-
In this paper, a novel speed control system that implements the fuzzy logic controller(FLC) is proposed. Fuzzy controller is shown more excellent efficency than a conventional controllers in the strength aspect and non-linear controller using IF-THEN rule which can control without process the accurate mathematical modeling about induction motor. But we cannot expect that conventional fuzzy controller divide equally the space of input and output parameter and use the certain shape of triangle membership function. Therefore to develop the efficiency of conventional fuzzy controller, We need to scale the range of membership functions. In this study, proposed fuzzy controller has the ability controlling scale of membership functions using by output scaling factor.
-
For the management of maximum demand power, power control system that is consist of CCMS(Central Control and Management System) and MCCS(Minimum Cost Control and management Software) is proposed. MCCS has the basic functions of the set of target power and the enrollment of load control logic. And also MCCS give the simulation of Power rate that help more effective Demand Control.
-
최근 대형 전력시설물에 대한 VE 와 LCC 기법의 도입은 여러 가지 형태로 수행되고 있으며, 일반적으로 전력 시설물의 비용을 생각할 때 그 초기투자비만을 대상으로 평가하는 경향이 있으나, 시설물의 총 생애비용 (보전비, 수선비, 개선비, 운용비, 전력비등)을 동시에 고려하여야 한다. 본 연구에서는 간선설계에서 장거리 급전시 전압강하로 인한 동손비를 고려한 설계기법과 내구년한에 따른 총생애비용기법을 적용하여 타당성을 입증하였다.
-
According to the realization of highly information dependent society, the recent building system is developed into the concept of suitable for management of intellegent work, which is demanded to unify of IBS(Intelligent Building System), IC(information communication), OA(office automation), BA(building automation) system and computer technology. However inspite of the presence arrester, cable shielding, insulated TR, filter, earth etc., in the IBS building for the cope with several surge and noise has several problems from the wrong operation of the equipment which caused from several surge, damage of equipment, and noise etc. And the miss operation caused by wrong earth works, which must be considered at first during the building construction. In order to minimize these problems, it's necessary that various earth project are performed effectively, and bonding methods between the mutual wiring of earth system and the equipments in the building should be improved sucessively. So in this paper, we analyze present domestic conditions of the earth technology in IBS building, and propose minimization method for the various surge and noise problem, and examine and analyze through the applied works.
-
Owing to WTO/TBT, Many countries are trying to accord their own various national codes and standards with international standards. Also Korean electric power code is being made consistent with the new standards which include the international standards. The new code will affect the many aspects of building construction. In order to cope with the change of the electric power code, this paper analyzed the trend of the international standard(IEC 60364, IEC 61024) and we think this study will help engineers to understand the international electrical standards.
-
Ground in must choose enough sectional area of conductor endurably in maximum fault current, fault duration time, maximum allowable temperature and have strong durability and life-time can bear enough from spontaneous corrosion or electrolytic corrosion and must choose material that problem does not exist electrically and mechanically when connection or junction. In this paper, modeled new ground wire size numerical formula, and examine and compare of modeled numerical formula and abroad regulation, and proved and analyzed validity of the new ground wire size computation method because do simulation to computer program.
-
The principle of the ultra-high frequency (UHF) method to detect partial discharge(PD) in GIS is to measure the UHF electromagnetic waves excited by PD pulses. Such electromagnetic waves propagate along the GIS busbar in the TEM-mode, TE-mode, TM-mode. And the coaxial busbar of the GIS acts as a waveguide in which the UHF electromagnetic waves travel. This paper was studied the analysis on damping characteristic of electromagnetic waves excited by PD in GIS and presented the method to yield the cutoff frequency for determine the minimum band of sensor that detect the PD pulse.
-
This paper studies islanding detection distributed of distributed generation(DG). The study of islanding detection has been disconnected DG when power islanding was detected but fault type wasn't distingish. Nearby feeder fault the fault of feeder that not interconnected DG, is a little affect DG and distribution system. Therefore DG not need to disconnect distribution system. We studied islanding detection algorithm considering fault location.
-
Recently, power-electronics equipments or machine that microprocessor is included and computers have been installed continuously in industrial process or region of electronics customer. So concern for power quality, especially sags has been increased. Because those equipments are very sensitive to sags. The sag is phenomenon that magnitude of load voltage temporarily decreases because of power system fault. If a certain equipment in industrial process have any trouble result from sag, it can cause utility to be charged for enormous economics loss. Therefore it need to analyze the characteristic of sag and then mitigation method for sags in distribution system in oder to increase reliability. This paper gives an overview of sags characteristic due to short circuit fault in distribution system and after a general discussion of the various forms mitigation, gives a sags mitigation method with concentrating on mitigation-device interface method, especially FCL that is Fault Current Limiter.
-
Street light facilities, which are easily accessible, can be in danger of electric shock when water percolates the facilities especially in summer. In case deteriorated facilities are not checked regularly, they can cause accidents such as electric shock. We should consider regional characteristics to prevent this kind of accidents. In this paper, we analyzed the problems according to the facilities through the research on the actual conditions. We also analyzed the facilities by region and the standards by the conditions.
-
원점(초점)에 놓인 광원(점광원)으로부터 방사된 ray들을 광축과 평행하게 진행하도록 그 진로의 방향을 바꾸어주는 것이 대형등명기의 광학부(중심렌즈부, 굴절링부, 절사프리즘부) 역할이다. 이러한 광학부에 대한 설계방법은 일부 서적에 소개되고 있지만, 광학부 설계시 각 부분마다 설계한계에 부딪히게 된다. 본 논문에서는 각각의 광학부에 대한 제한된 설계를 고찰하고 새로운 설계법을 도출하여 용이한 설계를 위해 설계법을 체계화시키는 작업에 대하여 설명하고 이 작업의 타당함을 확인하기 위해 계산에 의한 Ray Tracing과 배광예측프로그램인 Photopia 시뮬레이션의 결과를 제시하였다.
-
When a light is projected upon a material, part of its radiation energy is absorbed and the rest is reflected or transmitted according to the nature of the material. The molecules of the substance absorbing a light obtains the radiation energy to the wavelength of the light to make photochemical degradation by ultraviolet ray or thermal reactions like physical damage by infrared ray. The degree of damage by radiation energy varies to the substances of materials, the spectral power distribution of the light source and the duration of irradiation. Because the damage brings about a devaluation of material and once damaged, it is irretrievable, it is necessary to minimize the damage and conserve the native quality of a material by a protective lighting system. A measuring system was set up to measure the temperature rise of each sample by infrared radiation from light sources. And the temperature rise and temperature distribution by various infrared lamps were measured with varying time.
-
Digital Image와 휘도 측정치의 보정실험을 행하여 만족스러운 결과를 가져왔다. 그러나 피사체의 밝기에 비해 노출값을 너무 적게 하면 오차가 발생할 수 있다는 사실이 확인되었다. 앞으로 Videophotometry을 실현하기 위해서는 피 계측면의 분광 반사특성에 의한 계측치의 오차를 제거하기 위한 CCD 소자의 시감도 보정, 시야를 정확하게 재현하기 위한 광학적 연구, 인간의 시각 특성에 부합하는 측정 휘도의 보정 등에 대한 연구가 이루어져야 할 것이다.
-
본 연구에서는 초등학생들의 시력 저하에 작용될 수 있는 교실조명 환경에서의 문제점을 파악하기 위하여 주광 이용을 포함한 교실의 조명환경으로 책상면 조도, 칠판면 조도, 균제도, 휘도, 반사율등 시력에 작용되는 요소들을 측정하고 분석하였다. 교실조명의 문제점을 최소화시키기 위한 조명환경을 개선하고 개선된 조명환경 하에서 계절 변화에 따라 달라지는 조명 특성의 변화를 지속적으로 측정 분석하였다. 일정 기간 경과 후 개선된 환경에서 생활한 학생들과 개선되지 않은 환경에서 생활한 학생들의 시력의 변화를 측정하여 비교 분석함으로써 교실 조명환경이 학생들의 시력변화에 미치는 영향 및 상관 관계를 분석하고자 하였다.
-
현재, 연구진이 개발하고 있는 배광 측정기기를 위한 조명 계산용 소프트웨어는 일반적인 조명치들에 대한 계산 결과는 물론, 조명기구의 광학적 특성을 파악하는데 필요한 데이타를 제공한다. 조명용 배광 측정기기를 통해 조명기구의 배광 분포를 측정하게 되면, 이를 바탕으로 기구의 광학적 특성을 계산해낼 수 있는데, 이는 현재 개발하고 있는 조명 계산용 소프트웨어로 실현이 가능하다. 이러한 일련의 조명기구의 배광 측정과 그 해석이 조명 계산용 소프트웨어 개발의 주된 목적이라 할 수 있다. 본 논문에서는 그 동안 개발된 소프트웨어의 내용을 정리한 것이다.
-
Ring-shaped electrodeless fluorescent lamp is removed the internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[㎑]and some specific conditions. The optical measurement measured luminance and a temperature and an optical spectrum distribution for 10 minutes in a one minute interval at the same time.
-
무전극 형광 램프에서 플라즈마 생성이 용이한 유도 결합형 플라즈마가 많이 사용되는데, 코일의 권선수나 주파수에 의해 전기적 특성의 변화가 크다. 따라서, 기존의 환형 무전극 형광 램프에 사용되는 ferrite core나 coil을 새롭게 적용하기 위하여 투자율이 2000인 Mn-Zn ferrite를 사용하여 주파수와 coil의 권선수를 변화시켜 전기적 특성을 측정하여 기존의 환형 무전극 형광램프와 비교·검토하였다.
-
This paper analyzes the effects of various operating voltages on the electrical and light output characteristics of 20mW(5mm-Ф), 1W and 5W high-power RGB LEDs. Operating voltages of three types are compared on a simple LED circuit: DC, full-wave rectified DC. and square-wave DC. As a result, it is found that the 1W and 5W high-power LEDs should be provided with appropriate heat sinks that hold down the increase of junction temperature. As for the operating efficiency the case of full-wave rectification gives the highest value.
-
We propose a new watermarking scheme that can be used to embed multiple bits and also resilient to JPEG compression and geometrical transforms such as scaling, rotation, and cropping based on holographic watermark that allows multiple watermark recovery without original content(cover image).
-
We propose a new watermarking scheme that can be used to embed multiple bits and also resilient to JPEG compression and geometrical transforms such as scaling, rotation, and cropping, based on off-axis holographic watermark that allows multiple watermark recovery without original content(cover image). The holographic watermark is that Fourier transformed digital hologram is embedded into cover image in the spatial domain. The proposed method has not only increased robustness with a stronger embedding but also imperceptibility of the watermark in the evaluation process.
-
The most shortcoming of metalhalide lamps is what the instant restarting cannot be realized when the arc tube is in the hot condition. The discharge starting voltage of arc tube in the hot condition is much higher than in the cold condition. Therefore it takes about five minutes to restart the metalhalide lamps, that is to say, it is possible to start when the pressure and the temperature are decreased. But, if the lamp is restarted in the hot condition, we must supply the high voltage pulse with 20kV at the both sides of lamp. The proposed electronic ballast is consist of a electromagnetic interference (EMI) filter, a power factor correction (PFC) circuit, a flyback converter, a half-bridge inverter, and a high voltage igniter circuit. By this composition we can restart the lamp with the voltage 20kV, even if the lamp is in the hot condition.
-
우리는 황토 조명등을 제작하여 원 적외선 발생 실험을 하였다. 실험에는 백열전구 200W, 실내온도 21도, 습도 38%의 조건에서 열화상실험과 TF-IR(적외선 분광방사 측정장치)에 의한 원적외선 방사한도를 측정하였으며, 그 결과 방사율 0.914와 방사에너지 6.23
$\times$ $10^2$ (w/$m^2$ .$\mu\textrm{m}$ ) 가 얻어졌다. 이와 같은 결과로 황토조명등에서 원적외선이 발생한 것을 확인하였다. -
The purpose of this study is to analyze the slopes of control algorithm and dimming levels based on different inputs and parameters. Different parameters such as photosensor aiming angles, sky types, and seasonal changes were considered. To determine the slopes of control algorithm and dimming levels, photosensor signals and workplan illuminance values were simulated by DayDim program, which is a lighting calculation and analysis tool. A typical small office space was used for simulation and three different sky types in three different seasons were considered. This study shows that differences in dimming levels can occur according to different sky types, if system calibration is conducted in a particular sky type.
-
In the present, most lighting simulation programs are based on luminaires data produced at overseas. Currently, it is difficult to use proper domestic luminaire database in most lighting simulation programs, because there are only oversea luminaire database available. Therefore, in this study, domestic luminaire database were developed and categorized and applied to Internet Web-based RADIANCE rendering system. Luminaire database are constructed with 3D modelings, materials and IES data of each luminaire.
-
본 논문에서는 13[W] FPX 글로스타터 내장형 형광램프를 에너지 효율이 높고 회로설계가 용이한 전자식 안정기를 설계 제작하였다. 제작한 안정기는 우수한 기동특성을 보였으며 안정된 전기, 광학적 특성을 얻을 수 있었다.
-
본 논문에서는 36[W] FPL 형광등용 전자식 안정기의 페라이트 코아를 사용하는 인덕터를 대신 공심을 사용하는 안정기를 제작하였다. 전자식 안정기는 고주파 동작을 하기 때문에 그에 따르는 자성재료는 히스테리시스손의 발생이 더욱 커지는 현상을 이해하여 Air Coil의 특성을 적용한 전자식 안정기를 설계해 보았다.
-
본 논문에서는 91[W] 저압 나트륨 램프용 고효율 전자식 안정기를 제작하여 전기적 특성을 측정하였다. 개발된 고효율 전자식 안정기는 입력 전압 220[V], 입력 전류 641[mA], 입력 전력 137[W], 역률은 99[%], 전류 고조파 함유율 13[%]로 측정되었다.
-
Electrodeless fluorescent lamps utilizing an inductively coupled plasma were found to have a long lifetime and high efficacy and now are used in some indoor and outdoor applications. This paper gives a basic data of electrodeless fluorescent lamp ‘QL’(Philips). The experimetal system consist of QL 85W/840 lamp and QL 85W S/03 ballast.
-
본 연구에서는 패러데이 효과(Faraday Effect)를 이용한 초고압 전력설비에서의 광전류 센서의 특성에 대한 기초 연구를 하였다. 광원은 Laser Diode(1310[nm])를 사용하고, 수신부는 PIN-Photodiode를 사용하였다. 센싱부로 사용한 광섬유는 single mode unjacked fiber를 사용하였고, 편광기를 사용하여 빛의 광학적인 편파면을 이용한 전류측정이 가능함을 확인할 수 있었다. 측정 결과에서는 전류에 따른 출력 신호가 나옴으로써 기존 문헌상의 결과와 동일하다는 것을 알 수 있었고 센싱부로 사용한 파이버의 길이에 따른 출력차이를 통해 파이버의 길이가 길수록 강도가 커진다는 것을 알 수 있었다. 또한 길이에 따라 출력의 차이뿐만 아니라 선형성까지도 차이가 난다는 것을 알 수 있었다. reference 값과 광전류센서의 출력 강도와의 오차율을 구했을 때 5[m] 10[m]길이의 광섬유 각각에 대해서 1000[A]이상의 값에서 각각 약 -0.9[%], -0.4[%]의 오차율을 보임을 확인했다. 여기서 인가한 전류값과 길이 즉, 감은 수에 따라 그 오차율이 점점 나아질 수 있다는 것을 알 수 있었다.
-
Anodizing film was prepared by anodic oxidation of pure aluminum(purity > 99.50) using DC power supply for constant current mode in an electrolytic solution of surface of sulfuric acid. Effects of pre-treatment process such as chemical polishing, acid cleaning, alkali etching before anodic oxidation, were studied to microstructures and surface morphologies. A roughness on surface of anodizing film had to be decreased for amorphous phase by anodic oxidation. A roughness on surface of anodizing film decrease as annealing temperature increased in chemical polishing.
-
The voltage and current of fluoescent lamp has been successfully calculated in the case of frequency variation. Energy states of mercury atom in the discharge process are regarded as six levels. These calculations have been accurately solved by numerically employing mixed the FDM and the 2nd Runge-Kutta method. The theoretical calculation results and experimental results were presented to verify the feasibility of the modeling. Calculation and experimental results were presented to verify the feasibility of the calculation.
-
Characteristics of electrodeless lamp as a load of the ballast is different compared to normal fluorescent lamp because the lamp includes the magnetics for inductive discharging process. So somewhat different modeling is necessary to make a proper power match between the lamp and ballast. Modeling of an electrodeless lamps, Endura of Osram, is presented in this paper. Simulation with a result of experiment is given for a verification of proposed model.
-
With distribution industrial control system, the use of tow cost to achieve a highly reliable and safe system in real time distributed embedded application is proposed. This developed intelligent node is based on two microcontrollers, one for the execution of the application code, also as master controller for ensuring the real time control & the logic operation with PLD and other for communication task and the easy control execution, i.e., I/O digital input, digital output and interrupting. This paper also presents where the case NCS(Networked control system) with LonTalk protocol is applied for the filtration process control system of a small water treatment plant.
-
In this paper, a new distributed intelligent control module based on LonWorks fieldbus for air handling unit(AHU) of heating, ventilating and air-conditioning(HVAC) is proposed to replace with a conventional direct digital control(DDC) with 32 bit microprocessor. The proposed control architecture has a excellent features such as highly compact and flexible function design, a low priced smart front-end and reliable performance with various functions. This also addresses issues in control network configuration, logical design of field devices by S/W tool, Internet networking and electronic element installation. Experimental results showing the system performance are also included in this paper.
-
In this paper, web based monitoring systems are implemented using embedded Linux. The external equipment is controlled via HTTP protocol and web browser program. HTTP protocol is ported into Linux. A micro web server program and external equipment control program are installed on-board memory using CGI to be accessed by web browser. Experimental result of the proposed web based monitoring systems can be used in automation systems and remote distributed control via internet using web browser.
-
3차원 영상정보처리에 이용되는 변형 삼각간섭계는 인코히어런트 광을 이용한 3차원 영상정보의 기록과 복원에 이용되고 있다. 최근에는 3차원 영상의 기록과 재생이외의 분야, 예를 들면 3차원 물체의 결함검출 및 현미경분야에 대한 활용 연구도 진행되고 있다. 본 연구에서는 이러한 분야에 응용이 되고 있는 변형 삼각간섭계의 시스템개선과 시스템에 대한 전달함수와 PSF(point-spread function)의 일반화를 시도하였으며, 변형 삼각간섭계에 대한 복소홀로그램 생성과 수치적 복원영상결과도 제시하였다.
-
The importance of the improving quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and system. The transient overvoltage on low-voltage AC power distribution system are induced by direct or indirect lightning return strokes, and those can cause damage and/or malfunction of the utility system for borne automation, office automation and factory automation as well as medical equipments. The behavior of lightning surge transferred to the primary side from the primary side in distribution transformers were experimentally investigated the protection effect of low voltage SPD installed at the secondary side of distribution transformers was analyzed.
-
Today's electrical facilities demand improvements from the standpoints of non-inflammability, simple maintenance and inspection, safety and operating rationalization. The molded power with numerous special features that meet these various demands is acclaimed by all users and has a record of numerous applications. Its applications are expected to expend further in the future.
-
We analysed the operating properties of resistive type superconducting fault current limiters (SFCLs) based on YBCO thin films with a single line-to-ground fault. When a single line-to-ground fault occurred, the short circuit current of a fault phase increased up to about 6 times of transport currents immediately after the fault instant and was effectively limited to the designed current level within 2 ms by the resistance development of the SFCL. The fault currents of the sound phases almost did not change because of their direct grounding system. The unsymmetrical rates of a fault phase were distributed from 6.4 to 1.4. It was found that the unsymmetrical rates of currents were noticeably improved within one cycle after the fault instant. We calculated the zero phase currents for a single line-to-ground fault using the symmetrical component analysis. The positive sequence resistance was reduced remarkably right after the fault but eventually approached the balanced positive resistance component prior to the system fault. This means that the system reaches almost the three-phase symmetrical state in about 60 ㎳ after the fault. The ground currents were almost 3 times of the zero phase mts since most of the fault currents flowed through the grounding line.
-
This paper presents the result of survey of case study for Harmonics in electrical Installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. However, there are some difficulties on evaluating the measured data in comparison with the simulated result. The primary cause was indentitied with the resonance of harmonics form many sources. To suppress harmonics in electrical installations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.
-
This paper gives a method for the minimization of the fuel cost by optimal generation. Derivation of the sensitivity of system loss by optimization technique is introduced and the loss sensitivities are substituted into the optimality conditions to obtain the minimized fuel cost.
-
We research hardware and software for measurement of most suitable condition of the plant growth. that is put of the future oriented that plant growing system. The environment cannot offer the most suitable condition of the plant growth. so we are approached most suitable condition of the plant growth by adjustment of artificial condition of the plant growth but in theses experiment includes some fault that is subjectivity of observation. therefor we develop vision equipment and software for objective observation measurement.
-
In recent large power plants, the excitation system has the static type, which is characterized by the fast response to increase the transient stability. The high capacity excitation systems developed in KEPRI is either a hot back-up, hybrid hot back-up (analog + digital) or triple modular redundant digital type, both well proven by actual tests and applied in commercial operation. The large excitation systems have been developed taking into consideration the parameters of large scale power plants, resulting in high costs and subsequently are supplied at higher prices. When used at small sized power plants, the cost impact is relatively high. As a countermeasure to such a situation, KEPRI has recently developed a reliable, miniature digital excitation system, which is one-board type, convenient and adequate for low-price, small-sized (0.5MW∼200MW) power plants.
-
In this paper, proposed circuit proposes that Active-Clamp-Circuits basis of a current-fed inverter linked type high frequency resonant dc-dc converter of conventional. and the paper the most of characteristics of the reduced high voltage stress main switches with active clamp circuits and output current constant with the resonant part consists of L, C resonant tank circuit. Also, the capacitor (C
$_1$ , C$_2$ ) connected in switches are a common using by resonance capacitor and ZVS capacitor. and circuit analysis used state equation of each part modes. Also we conform a rightfulness theoretical analysis by comparing a parameters values and simulation values obtained from simulation using Power MOS-FET as switching devices. -
This paper deals with the position control of an AC servo motor using linear hall-effect sensors. The price of these is very low, but it is possible to make position control of motor similar to a control using an encoder. This paper introduces the design of motor using linear hall-effect sensors and shows the results of control.
-
본 논문은 누전차단기의 충격파 부동작 특성과 전자기적합성(EMC) 특성비교에 관한 것이다 국내 규격에서는 충격파 부동작 성능만 확인하지만 국제규격에서는 많은 EMC 항목이 있다. 누전차단기 17종에 대하여 EMC 4항목을 실시한 결과, IEC 61000-4-5에 따른 조합서지 내성에서 9종이 불량이었다. 다른 항목에서는 불량이 발생하지 않았다. 오동작만 발생한 시료 2종에 대하여 충격파 부동작 성능을 평가한 결과 오동작이 발생하지 않았다. 이것으로 보아 EMC와 충격파 부동작 시험은 상관관계가 적으며 보완이 필요함을 알 수 있다.
-
본 논문은 에폭시 지지애자에 센서를 내장하여 활선상태를 감지할 수 있는 제품개발에 관한 것이다. 개발된 제품은 KS C 3835에 따라 7.2[㎸], 12[㎸]및 24[㎸]전압용이다. 지지애자에 내장된 센서 재질은 부분방전이 발생하지 않도록 애자 재질과 동일하게 하였다. 또한 활선상태를 확인할 수 있는 현장용 및 원격용 전압표시장치를 개발하였다. 개발된 애자본체에 대해서는 부분방전, 충격내전압, 상용주파내전압, 굽힘 강도 등 성능평가를 실시하였으며 만족할 만한 결과를 얻었다. 전압표시장치에 대하여도 상용주파내전압 충격 내전압, 진동성 서지, 온도특성 등을 확인한 결과 만족할 만한 결과를 얻었다.
-
본 논문은 마이크로프로세서 및 전력용반도체인 사이리스터로 제어되는L-C 고조파 필터에 관한 것이다. 개발된 고조파 필터는 3상 220[V]이며 25[㎸A]5고조파 제거용이다. 또한 고조파 필터는 콘덴서에 의해 역률을 개선하는 역할을 한다. 고조파 전류 발생시 3사이클 이내에 고조파 필터가 동작하며, 제로 크로싱 제어로 개폐시 과도서지가 발생하지 않는다. 전류변동에 따른 응답속도가 빨라 부수적으로 전압변동에 의한 플리커 현상을 해소시키는 역할도 한다. 개발된 제품에 대하여 안전성능 및 일반성능 실험결과 만족할 만한 결과를 얻었다.
-
In this paper, in order to analyzing the thrust force of LDM, it was divided by the vertical force(Fx)and the horizontal force(Fy). The magnet and winding width was determined by analyzing the magnetic flux distribution throughout the airgap of LDM. Using finite-element analysis(FEA), which is the magnetic field analysis, and Proved the validity of design process, also the characteristics of LDM according to the variation of the design parameters of LDM was almost in accord with th experiment results.
-
A Design of PFC Circuit for Reducing the Harmonic in Constant Voltage-fed Electronic Ballast CircuitIn this paper, a PFC(Power Factor Correction) electronic ballast with constant voltage-fed is proposed. The proposed PFC electronic ballast is combined of a High-efficiency boost converter and a conventional half bridge inverter. It is proved that the ripple of input-current and the input-current's harmonic of the proposed PFC electronic ballast are reduced using the voltage divider and soft-switching technique. It is demonstrated that simulation results for 40[W] fluorescent lamp correspond with theoretical analysis
-
Airport facility is infrastructure that become external creditworthiness and linear measure of country competitive power. Among them, receive and supply of electric power facility of airport is very important in peculiarity, trustability, safety side of airport. In this parer, sorted domestic airline as 4 classes by code to accomplish standardization for receive and supply of electric power facility of airport. And established justice and coverage about receive and supply of electric power facility using without any standard present and analyze problem for receive and supply of electric power facility of existing airport and presents standard. Finally, present standard single-line diagram by airport grade and system grade standard of receive and supply of electric power facility of airport.
-
In this paper, an identification method for a first order dead time process is proposed. This method used the genetic algorithm for parameter identification of process. The proposed method gives a better identification result than the existing methods under step testing. The effectiveness of the identification method has been demonstrated through a number of simulation examples.
-
The purpose of this research was to discuss the system that operated Ultra sonic transducer of Pelzo electric ceramics type. The structure of controller was made up of digital signal part drive and feedback circuit, and half bridge inverter. Digital signal part was designed to gain the stable oscillation frequency by making consideration of pointed resonance bandwidth. We tried to control inverter by forward feedback condition because BLT based on the flexibility of elements such as temperature and load condition. In addition, transducer was operated as inverter in order to enhance its power efficiency. In this experiment, output voltage waveform and current waveform have been observed by using BLT.
-
Total six units of 3㎾ photovoltaic system and data acquisition system (DAS) are constructed for analyzing performance of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied. operation characteristics of the PV system are collected and analyzed in data-acquisition system furthermore, not only performance test of each PV system component such as PV module and power conditioning system but also performance of total PV system e.g. system efficiency power and loss factor at the site are reviewed.
-
To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is remarkedly increased. This paper presents how the impulse and fault current works on the long. vertical ground rods associated with incoming points. When the test current was injected at the bottom of ground rod, the potential waveform of ground rod includes the oscillation with high frequency.
-
A new method measuring soil resistivity in frequency range of 5-500[KHz] using variable frequency inverter was presented, and soil resistivity was analysed by resistive and reactive components on the basis of magnitude and phase of measured ground impedance. The test lead arrangement was proposed to reduce the inductive coupling in test circuit for measuring the soil resistivity. The frequency dependence of soil resistivity was mainly caused by the inductive current flowing through grounding conductors over the frequency of 70[KHz].
-
XLPE(Crosslinkable Polyethylene) 케이블은 절연성이 우수하여 전력용으로 많이 사용되고 있다. 그러나, 시설된지 오래된 케이블의 노후화와 지중 매설 케이블의 시공시 및 포설이후 외부손상 등으로 인해 정전사고가 많이 발생하고 있는 추세이다. 본 논문은 케이블의 외부 손상에 의해 발생하는 부분방전에 의해 공간으로 전파되는 전자파를 측정하는 UHF법을 통해 주파수 스펙트럼을 측정하고 측정된 데이터 처리를 통해 방전진전에 따른 스펙트럼의 특성을 분석하였다.
$^{[1]}$ [3][6]// -
In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating
$\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap$\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode. -
In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.
-
현장에서 많이 사용되고 있는 GIS에 결함이 발생하면 치명적인 사고로 진전될 수가 있다. 본 논문은 모의 GIS내 도전성 금속이물질 존재 시 발생되는 부분방전 신호를 절연 진단 방법중 하나인 UHF법을 이용하여 부분방전 시 방사되는 방사전자파의 스펙트럼을 분석해 금속이물질이 SF
$_{6}$ 가스부분방전에 미치는 영향을 측정하였다. 이러한 연구는 현장 GIS 및 SF$_{6}$ 가스절연 전력설비에서 금속이물질에 의해 발생되는 절연파괴 사고의 방지에 중요한 역할을 할 것으로 사료된다. -
A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.
-
For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FET and the like. The absence of switching devices mattes systems more tolerant to over-load and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced The result are confirmed by the theoretical and experimental implementations.