• 제목/요약/키워드: zero-crossing time

Search Result 124, Processing Time 0.029 seconds

Alleviate Current Distortion of Dual-buck Inverter During Reactive Power Support (듀얼벅 인버터의 무효전력 보상 시 전류 왜곡 저감)

  • Han, Sanghun;Cho, Younghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.134-141
    • /
    • 2022
  • This study presents a method for reducing current distortion that occurs when a dual-buck inverter generates reactive power. Dual-buck inverters, which are only capable of unity power factor operation, can generate reactive power capabilities by modifying a modulation technique. However, under non-unity power factor conditions, current distortion occurs at zero-crossing points of grid voltage and output current. This distortion is caused by parasitic capacitors, dead-time, and discontinuous conduction mode operation. This study proposes a modified modulation method to alleviate the current distortion at zero-crossing point of the grid voltage. A repetitive controller is applied to reduce this distortion of the output current. A 1 kVA prototype is built and tested. Simulation and experimental results demonstrate the effectiveness of the proposed method.

Discrimination of neutrons and gamma-rays in plastic scintillator based on spiking cortical model

  • Bing-Qi Liu;Hao-Ran Liu;Lan Chang;Yu-Xin Cheng;Zhuo Zuo;Peng Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3359-3366
    • /
    • 2023
  • In this study, a spiking cortical model (SCM) based n-g discrimination method is proposed. The SCM-based algorithm is compared with three other methods, namely: (i) the pulse-coupled neural network (PCNN), (ii) the charge comparison, and (iii) the zero-crossing. The objective evaluation criteria used for the comparison are the FoM-value and the time consumption of discrimination. Experimental results demonstrated that our proposed method outperforms the other methods significantly with the highest FoM-value. Specifically, the proposed method exhibits a 34.81% improvement compared with the PCNN, a 50.29% improvement compared with the charge comparison, and a 110.02% improvement compared with the zero-crossing. Additionally, the proposed method features the second-fastest discrimination time, where it is 75.67% faster than the PCNN, 70.65% faster than the charge comparison and 38.4% slower than the zero-crossing. Our study also discusses the role and change pattern of each parameter of the SCM to guide the selection process. It concludes that the SCM's outstanding ability to recognize the dynamic information in the pulse signal, improved accuracy when compared to the PCNN, and better computational complexity enables the SCM to exhibit excellent n-γ discrimination performance while consuming less time.

Simulation of a Non-Directional Wave Spectrum Analysis with Welch's Method

  • Park, Soo-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.146-149
    • /
    • 2008
  • Simulation and signal conditioning on the time domain surface elevation records are conducted to verify the proposed Welch's method in non-directional ocean wave spectrum analysis. These spectrum data are further conditioned to provide wave characteristic that better describe the sea states. Comparison of significant wave height and zero crossing period between the proposed method and a reference toolkit are presented.

Development an embedded module for nondirectional wave spectrum analysis

  • Park, Soo-Hong;Wong, Sheng-Chao
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.454-461
    • /
    • 2008
  • This embedded module measures significant wave height and zero crossing periods through spectral energy from a record of time series heave motion. An ARM7TDMI core microcontroller serves as the main control unit which performs the appropriate control and signal conditioning. Monitored wave characteristic is transmitted with satellite modem. Mathematical equations on signal conditioning and experiments procedures are documented in this paper.

Fault Detection for Ceramic Heater in CVD Equipment using Zero-Crossing Rate and Gaussian Mixture Model (영교차율과 가우시안 혼합모델을 이용한 박막증착장비의 세라믹 히터 결함 검출)

  • Ko, JinSeok;Mu, XiangBin;Rheem, JaeYeol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.67-72
    • /
    • 2013
  • Temperature is a critical parameter in yield improvement for wafer manufacturing. In chemical vapor deposition (CVD) equipment, crack defect in ceramic heater leads to yield reduction, however, there is no suitable ceramic heater fault detection system for conventional CVD equipment. This paper proposes a short-time zero-crossing rate based fault detection method for the ceramic heater in CVD equipment. The proposed method measures the output signal ($V_{pp}$) of RF filter and extracts the zero-crossing rate (ZCR) as feature vector. The extracted feature vectors have a discriminant power and Gaussian mixture model (GMM) based fault detection method can detect fault in ceramic heater. Experimental results, carried out by measured signals provided by a CVD equipment manufacturer, indicate that the proposed method detects effectively faults in various process conditions.

Measurement and Statistical Analysis of Magnetic Fields Produced by Cloud Discharges (운방전에 의해 발생되는 자장의 계측과 통계적 분석)

  • Lee Bok-Hee;Gil Hyoung-.Jun;Cho Sung-Chul;Shim Eung-Bo;Woo Jung-Wook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.262-268
    • /
    • 2005
  • In this work, to obtain the detailed information about lightning electromagnetic field waveforms, the LabVIEW based-measurement system of time-changing magnetic fields was designed and constructed. The frequency bandwidth of the magnetic field measuring system ranges from 300 [Hz] to 1 [MHz], and the response sensitivity is 2.78 [mV/nT]. Data acquisition system with the resolution of 12 bits and memory capacity of 32 [Mbyte] was triggered by the magnetic field to be measured. The properties and parameters of the magnetic fields produced by cloud discharges were statistically investigated. The magnetic field waveforms radiated from cloud lighting discharges tend to be bipolar, with two or more narrow and several pulses superimposed on the initial front part. The recording length of the magnetic field measurement system is about 10 [ms]. The mean duration of cloud discharges is 1.3 [ms], and the number of outburst pulses for the period is 8 in average. The front times of the magnetic fields are 6.15 [$\mu$s] in average. The the zero-to-zero crossing times that is the initial half-cycle duration is widely dispersed and the mean value is 9.61 [$\mu$s], and the mean value of percentage depth of dip to opposite polarity is 41.1 [$\%$].

A Numerical Study on the Simultaneous Identification of Excitation Force and Restoring Characteristic in Linear Forced Oscillation System (선형 조화 가진 시스템에서의 외부 가진력 및 복원 특성 동시 인식에 대한 수치 연구)

  • Jang, Taek Soo;Park, Jinsoo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.12
    • /
    • pp.943-947
    • /
    • 2014
  • Recently, a new method for reconstructing a forced nonlinear dynamic system has been proposed; specifically, the simultaneous reconstruction of its excitation as well as restoring characteristics of the system. The reconstruction was just theoretically shown to be possible by measuring the system's responses, based on newly introduced notions, a J-function and a zero-crossing time. However, numerically in the current paper, we are to reconstruct a linear system, i.e., we focus on numerical experiments to reconstruct both the excitation and the linear restoring characteristic of a linear forced oscillating system by using response data, based on the J-function and the zero-crossing time.

Statistical Properties of Electric Fields Produced by Cloud-to-Ground Lightning Return Strokes

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Seung-Chil;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.120-126
    • /
    • 2001
  • For the past five years, Inha University has been observing the electric fields produced by cloud-to-ground return strokes. This paper presents the summary of most recent results. Statistics on the zero-to-peak rise time, the zero-to-zero crossing time and the amplitude ratio of the second peak in the opposite polarity to the first peak were examined. The radiation electric fields produced by distant cloud-to-ground return strokes were substantially same pattern. The first return stroke field starts with a slowly increasing front and rises abruptly to peak. The rising portions of the electric fields produced by cloud-to-ground return strokes last 1 $mutextrm{s}$ to a few $mutextrm{s}$. The mean values of the zero-to-peak rise times of electric fields were 5.72 $mutextrm{s}$ and 4.12 $mutextrm{s}$ for the positive and the negative cloud-to-ground return strokes, respectively. The mean of the zero-to-zero crossing time for the positive return strokes was 29.48 $mutextrm{s}$ compared with 38.54 $mutextrm{s}$ for the negative return strokes. The depths of the dip after the peak of return stroke electric fields also have the dependence on the polarity of cloud-to-ground return stroke, and the mean values for the positive and negative cloud-to-ground return strokes were 33.55 and 28.19%, respectively.

  • PDF

A New Endpoint Detection Method Based on Chaotic System Features for Digital Isolated Word Recognition System

  • Zang, Xian;Chong, Kil-To
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.37-39
    • /
    • 2009
  • In the research of speech recognition, locating the beginning and end of a speech utterance in a background of noise is of great importance. Since the background noise presenting to record will introduce disturbance while we just want to get the stationary parameters to represent the corresponding speech section, in particular, a major source of error in automatic recognition system of isolated words is the inaccurate detection of beginning and ending boundaries of test and reference templates, thus we must find potent method to remove the unnecessary regions of a speech signal. The conventional methods for speech endpoint detection are based on two simple time-domain measurements - short-time energy, and short-time zero-crossing rate, which couldn't guarantee the precise results if in the low signal-to-noise ratio environments. This paper proposes a novel approach that finds the Lyapunov exponent of time-domain waveform. This proposed method has no use for obtaining the frequency-domain parameters for endpoint detection process, e.g. Mel-Scale Features, which have been introduced in other paper. Comparing with the conventional methods based on short-time energy and short-time zero-crossing rate, the novel approach based on time-domain Lyapunov Exponents(LEs) is low complexity and suitable for Digital Isolated Word Recognition System.

  • PDF

A New On-Line Dead-Time Compensator for Single-Phase PV Inverter (단상 PV 인버터용 온라인 데드타임 보상기 연구)

  • Vu, Trung-Kien;Lee, Sang-Hoey;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.409-415
    • /
    • 2012
  • This paper presents a new software-based on-line dead-time compensation technique for a single-phase grid-connected photovoltaic (PV) inverter system. To prevent a short circuit in the inverter arms, a switching delay time must be inserted in the pulse width modulation (PWM) signals. This causes the dead-time effect, which degrades the system performance around zero-crossing point of the output current. To reduce the dead-time effect around the zero-crossing point of grid current, a harmonic mitigation of grid current is used as an additional part of the synchronous frame current control scheme. This additional task mitigates the harmonic components caused by the dead-time from the grid current. Simulation and experimental results are shown to verify the effectiveness of the proposed dead-time compensation method in the single-phase grid-connected inverter system.