• Title/Summary/Keyword: zero properties

Search Result 808, Processing Time 0.028 seconds

Shear Behavior of RC Beams Using Alkali Activated Slag Concrete (알칼리 활성 슬래그 콘크리트를 사용한 RC 보의 전단거동)

  • Choi, Sung;Lee, Kwang-Myong;Yoo, Sung-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 2015
  • Several researches on cement zero concrete using alkali-activators have been conducted to investigate its fundamental material properties such as slump, strength and durability, however, research on the structural behavior of relevant members involving the elastic modulus, stress-strain relationship is essential for the application of this cement zero concrete to structural members. In this paper the shear behavior of reinforced concrete beams using 50 MPa-alkali activated slag concrete was experimentally evaluated. To achieve such a goal, six reinforced concrete beam specimens were fabricated and their shear behaviors were observed. The maximum difference between test results and analysis results in crack shear stress for beam specimens without stirrups is 31%, while that for beam specimens with stirrup is 15%. Furthermore, it is also found that the shear strength of alkali activated slag concrete is by 22~57% greater than the nominal shear strength calculated by design code, implying that shear design equations would provide conservative results on the safety side.

A cost-effective method to prepare size-controlled nanoscale zero-valent iron for nitrate reduction

  • Ruiz-Torres, Claudio Adrian;Araujo-Martinez, Rene Fernando;Martinez-Castanon, Gabriel Alejandro;Morales-Sanchez, J. Elpidio;Lee, Tae-Jin;Shin, Hyun-Sang;Hwang, Yuhoon;Hurtado-Macias, Abel;Ruiz, Facundo
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.463-473
    • /
    • 2019
  • Nanoscale zero-valent iron (nZVI) has proved to be an effective tool in applied environmental nanotechnology, where the decreased particle diameter provides a drastic change in the properties and efficiency of nanomaterials used in water purification. However, the agglomeration and colloidal instability represent a problematic and a remarkable reduction in nZVI reactivity. In view of that, this study reports a simple and cost-effective new strategy for ultra-small (< 7.5%) distributed functionalized nZVI-EG (1-9 nm), with high colloidal stability and reduction capacity. These were obtained without inert conditions, using a simple, economical synthesis methodology employing two stabilization mechanisms based on the use of non-aqueous solvent (methanol) and ethylene glycol (EG) as a stabilizer. The information from UV-Vis absorption spectroscopy and Fourier transform infrared spectroscopy suggests iron ion coordination by interaction with methanol molecules. Subsequently, after nZVI formation, particle-surface modification occurs by the addition of the EG. Size distribution analysis shows an average diameter of 4.23 nm and the predominance (> 90%) of particles with sizes < 6.10 nm. Evaluation of the stability of functionalized nZVI by sedimentation test and a dynamic light-scattering technique, demonstrated very high colloidal stability. The ultra-small particles displayed a rapid and high nitrate removal capacity from water.

A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography (산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.345-353
    • /
    • 2021
  • Digital radiography imaging systems can also help diagnose lesions in patients, but if x-rays that enter the human body cause scatter x-ray due to interaction with substances, they affect the signal and noise characteristics of digital x-ray images. To regard the human body as polymethyl methacrylate (PMMA) and observe the properties of scattered x-ray generated from PMMA on x-ray images, we analyze signal and noise in the spatial domain as well as noise-power spectrum (NPS), and detective quantum efficiency (DQE) at zero frequency. As PMMA thickness increased, signals decreased, the noise increased, and NPS degradation was identified in overall spatial frequencies. Based on these characteristics, zero-frequency performance was also shown to be degraded. Comparative analysis with Monte-carlo simulations will need to be made to analyze the zero-frequency performance by scattered x-ray of indirect conversion-type x-ray detectors more quantitatively.

Impact Analysis of Communication Time Delay and Properties of a Haptic Device on Stability Boundary for a Haptic System with a First-Order Hold (일차홀드 방식을 포함한 햅틱 시스템의 안정성 영역에 대한 통신시간지연과 햅틱장치 물성치의 영향 분석)

  • Lee, Kyungno
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.572-578
    • /
    • 2017
  • Haptic systems help users feel a realistic sensation when they manipulate virtual objects in the remote virtual environment. However, there are communication time delays that may make the haptic system unstable. This paper shows the relationship between communication time delay, properties of a haptic device, and the stability of the haptic system with the first-order hold method in a simulation. The maximum available stiffness of a virtual spring with the first-order hold method is larger than in the zero-order hold method when there is no time delay. However, when the communication time delay is much larger than the sampling time, the maximum available stiffness to guarantee the stability becomes the same, irrespective of the sample-hold methods. Besides, the maximum available stiffness increases in inverse proportion to the communication time delay and in proportional to the damping coefficient of the haptic device.

Microwave Dielectric Properties of $MgTiO_{3}$ Ceramics ($MgTiO_{3}$ 계 세라믹스의 고주파 유전특성)

  • Kim, Wang-Seop;Kim, Gyeong-Yong
    • Korean Journal of Materials Research
    • /
    • v.5 no.2
    • /
    • pp.246-250
    • /
    • 1995
  • Microwave properties of $CaTiO_{3}$, MgO and CaO added $MgTiO_{3}$ ceramics are investigated. In the composition of $(Mg_{0.915}Ca_{0.085})TiO_3$, dielectric constant($varepsilon _T$) was 22, Qxf value was 50000, and temperature coefficient of resonant frequency($gamma_T$) approached to near zero $ppm/^{\circ}C$.$MgTiO_{3}$ ceramics with 0.1 mol of MgO showed the highest Qxf calue of 131000, dielectric constant of 17, and r, of -$50ppm/^{\circ}C$. Dielectric constant of 8 mol% CaO added to $MgTiO_{3}$-MgO was 20. Qxf valus was 52000, and sf was zero $ppm/^{\circ}C$. $MgTiO_{3}$-Mg0-Ca0 system showed higher Qxf value than ($Mg_{1-x}, Ca_x$) Ti03 system.

  • PDF

A Study on Development of the Displacement Sensor of CoFeSiB Amorphous Alloy Magnetic Ribbon (CoFeSiB 아몰퍼스합금 자기리본 변위센서 개발에 관한 연구)

  • 강재덕;신용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.2
    • /
    • pp.163-168
    • /
    • 2001
  • This dissertation describes the development of a sensor for measuring microscopic displacement where we use CoFeSiB amorphous alloy magnetic ribbon having near zero magnetostrictive properties. For the development of the sensor, we first fabricate amorphous alloy magnetic ribbon, and then investigate its physical and magnetic properties. Finally, its possibility of practical application as a displacement sensor is discussed. The experimental samples were made of near zero magnetostrictive (Co$\_$0.94/Fe$\_$0.06/)$\_$9/Si$_2$B$\_$19/ alloy which were fabricated by a rapid liquid quenching method. As a results, we got amorphous alloy magnetic ribbons of 12㎛ in thickness, 10 mm in length, and 2.5 m in width. It was found that the crystallization temperature and the Curie temperature are around 451$\^{C}$ and around 441$\^{C}$ respectively. We couldn't observe any noticeable change of the impedance frequency of 10MHz, but observed the impedance change of 3.76 %/Oe at 100 MHz. The inductance was nearly stable over the frequency range of 1∼10 MHz, In addition, it was observed that the variation of the inductance and the impedance were linear within the displacement ranges of 20∼60㎛. As the results of the experiments, it is suggested that the displacement sensor which is fabricated by using amorphous alloy magnetic ribbon of (Co$\_$0.04/Fe$\_$0.06/)$\_$79/Si$_2$B$\_$19/ compound, can be used as a sensor to detect microscopic displacement.

  • PDF

Preparation of Biodegradable PLGA Microspheres for Sustained Local Anesthesia and Their in vitro Release Behavior (지속적인 국소마취를 위한 생분해성 PLGA 미립구의 제조와 생체외 방출 거동)

  • 조진철;강길선;최학수;이종문;이해방
    • Polymer(Korea)
    • /
    • v.24 no.5
    • /
    • pp.728-735
    • /
    • 2000
  • Fentanyl-loaded biodegradable poly(L-lactide-co-glycolide) (75 : 25 by mole ratio of lactide to glycolide, PLGA) microspheres (MSs) were prepared to study the possibility for long-acting local anesthesia. We developed the fentanyl base (FB, slightly water-soluble)-loaded PLGA MSs by means of conventional O/W solvent evaporation method. The size of MSs was in the range of 10~150 ${\mu}{\textrm}{m}$. The morphology of MSs was characterized by SEM, and the in vitro release amounts of FB were analyzed by HPLC. The lowest porous cross-sectional morphology and the highest encapsulation efficiency were obtained by using gelatin as an emulsifier. The influences of several preparation parameters, such as emulsifier types, molecular weights and concentrations of PLGA, and initial drug loading amount, etc., have been observed in the release patterns of FB. The release of FB in vitro was more prolonged over 25 days, with close to zero-order pattern by controlling the preparation parameters. We also investigated the physicochemical properties of FB-loaded PLGA MSs by X-ray diffraction and differential scanning calorimeter.

  • PDF

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

The Characteristices of Step Responses of the Manabe Standard Forms and Its Application to the Controller Desegn (Manabe 표준형의 계단 응답 특성 및 제어기설계에의 응용)

  • Gang, Hwan-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.586-592
    • /
    • 1999
  • We investigate the characteristic of 소데 responses of the Manabe standard form which is used recently for design of the controller. We obtain some theorems and these theorems have the properties of the relationship between the roots of the polynomial and the stability indices which are used for the Manabe standard form. The Manabe standard form has the following properties: The sum of the squal to zero, the sum of the reciprocal of the squared roots is greater than zero and the parameter $\tau$ is the negative value of the sum of the reciprocal of the roots. We compare the step responses of the Manabe standard form with those of the ITAE form, the dead beat response and Bessel forms. We choose the 6th order closed loop polynomial and keep the same settling time for the four forms. Under these conditions we find that the Manabe standard form have faster 90% rising time than the Bessel and dead beat response. We see that the ITAE, bessel and dead beat responses have some overshoot, whereas the Manabe standard form has none. We also compare the Manabe form with the other three forms for the controller design using the pole assignment technique. If the open loop transfer function is a type-1 system (transfer functions having one integrator), then, for the closed loop system associated with the open loop transfer function, the steady state error of the unit ramp input is obtained in terms of the parameter $\tau$ of the Manabe standard form.

  • PDF

Functional Ceramic Filter Fabrication for As Removal in Aqueous Solutions (수용액상의 As 제거를 위한 기능성 세라믹 필터 제조)

  • Cho, Kanghee;Choi, Nag-Choul;Kim, Song-Bae;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.173-178
    • /
    • 2017
  • In this study, the effect of sintering temperature and zero valent iron (ZVI) content on the physical properties of functional ceramic filter(alumina based materials) such as strength and porosity were investigated. The fabrication process of the functional ceramic filter were performed under various sintering temperature ($1150^{\circ}C$, $1250^{\circ}C$) and ZVI content (10, 20, 30, 50%) conditions. With increasing the sintering temperature and ZVI content, strength was increased but porosity was decreased. The physical properties for functional ceramic filter showed that the strength and porosity were obtained under ZVI content (50%) and sintering temperature ($1250^{\circ}C$) of 99.01 MPa and 34.5%, respectively.