• Title/Summary/Keyword: wood resistance

Search Result 302, Processing Time 0.022 seconds

A Study on the Fabrication of the Laminated Wood Composed of Poplar and Larch (포푸라와 일본잎갈나무의 집성재 제조에 관한 연구)

  • Jo, Jae-Myeong;Kang, Sun-Goo;Kim, Ki-Hyeon;Chung, Byeong-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.25-31
    • /
    • 1974
  • 1. Various gluing qualities applying Resorcinol Plyophen #6000 were studied on aiming the strength relationships of laminated woods resulted by single species [poplar (Populus deltoides), larch(Larix leptolepis)], mixed species of (poplar and larch), preservatives, treated poplar the scarf joint with mixed species of poplar and larch and the scarf joint treated with preservatives. 1. 1 On the block shear and on the DVL tension test, the mean wood failure ratio showed an excellent value i.e., above 65% and the tangential strength for larch was higher than that of radial, but it was reversed for poplar as shown in Tables 1 and 2. 1. 2 The lamina treated with Na-PCP reduced slightly the strength but the limited strength allowed for manufacturing laminated wood was not influenced by treating Na-PCP as shown in Tables 3 and 4. 1. 3 The safe scarf ratio in the plane scarf joint was above 1/12 for larch and 1/6 for poplar regard less of the chemical treatment or untreatment as shown in Tables. 5, 6, 7 and 8. 2. In the normal and boiled state, the gluing quality of the laminated wood composed of single[poplar (Populus deltoides), larch (Larix leptolepis)] and double species (poplar and larch) glued with Resorcinol Plyophen #6000 were measured as follow, and also represented the delamination of the same laminated wood. 2.1 The normal block shear strength of the straight and curved laminated wood (in life size) were more than three times of the standards adhesion strength. And, the value of the boiled stock was decreased to one half of the standard shear adhesion strength, but it was more than twice the standard strength for the boiled stock. Thus, it was recognized that the water resistance of the Resorcinol Plyophen #6000 was very high as shown in Tables 9 and 10. 2. 2 The delamination ratio of the straight and curved laminated woods in respect of their composition were decraesed, in turn, in the following order i. e., larch, mixed stock (larch+poplar) and poplar. The maximum value represented by the larch was 3.5% but it was below the limited value as shown in Table 11. 3. The various strengthes i.e., compressive, bending and adhesion obtainted by the straight laminaced wood which were constructed by five plies of single and double species of lamina i. e., larch (Larix leptolepis) and poplar (Populus euramericana), glued with urea resin were shown as follows: 3. 1 If desired a higher strength of architectural laminated wood composed of poplar (P) and larch (L), the combination of the laminas should be arranged as follows, L+P+L+P+L as shown in Table 12. 3.2 The strength of laminated wood composed of laminas which included pith and knots was conside rably decreased than that of clear lamina as shown Table 13. 3.3 The shear strength of the FPL block of the straight laminated wood constructed by the same species which were glued with urea adhesives was more than twice the limited adhesion strength, thus it makes possible to use it for interior constructional stock.

  • PDF

Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties - (낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 -)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • Shearing strength test in tension type was investigated to determine the shear resistance of bolt and drift-pin connection of domestic larix glulam. The specimen was connected with bolt and drift-pin in the inserted plate type, and only bolt in the side plate type. The diameter of bolt and drift-pin used in the experiment are 12, 16 and 20 mm. The hole of bolt was drilled at the end-distance 5 d and 7 d. Tension load was loaded in the direction parallel to grain. The shear resistance was evaluated according to end-distance through this, the yield load was compared with the experimental yield load, using Larsen's formula. The prototype design strength is based on the yield load of end-distance 7 d and the reduction factor of end-distance 5 d was calculated. The results were as follows. 1. The average of maximum load of drift-pin connection was higher by 3~30% at the inserted type than at bolt connection with increasing diameter. In bolt connection, the average of maximum load of the side type was 1.54~2.07 times higher than that of the inserted type. In the same diameter, the average of maximum load of end-distance 7 d was higher by 8~44% than that of 5 d. 2. The bearing stress was 1.16~1.41 times higher at the inserted connection than at drift-pin connection, and 1.37~1.86 times higher at 7 d than at 5 d. Also, when the slenderness ratio was below 7.5 at drift-pin connection and below 6.0 at inserted connection, the lateral capacity was good. 3. The ratio of the experimental yield load and the predicted yield load calculated by Larsen's formula proposed by Larsen was 0.80~1.10 at inserted connection, and 0.75~1.46 at side connection. 4. When the inserted bolt connection was based on the yield load of end-distance 7 d, the reduction factor was 0.89 at 12 mm connection, 0.93 at 16 mm and 0.85 at 20 mm. The reduction factor was 0.89 at 12 mm the inserted drift-pin connection, 0.93 at 16 mm, 0.93 at 20 mm. The reduction factor was 0.79 at the side connection of the 12 mm bolt connection and 0.80 at 16 mm.

Decay and Termite Resistance of Yellow-Hearted Pine (Pinus densiflora for. erecta Uyeki) (황장목의 부후 및 흰개미 저항성)

  • Lee, Ae-Hee;Jang, Jae-Hyuk;Hwang, Won-Joung;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.12-19
    • /
    • 2017
  • Yellow-hearted pine (YHP; Pinus densiflora for. erecta Uyeki) is one of the Red pine species and has extremely narrow growth ring and high ratio of heartwood growing in Korea. It has been used for valuable wooden constructions as palace and temple for royal family since the Joseon Dynasty period. However, scientific information on the wood properties of YHP is still very lacking. This study was carried out to investigate natural durability of YHP to fungi and termites attack. Examination of anti-fungal and anti-termite properties of YHP was performed at indoor condition using brown-rot fungi (Fomitopsis palustris), white-rot fungi (Trametes versicolor), and termite (Reticulitermes speratus). The results showed that weight loss of the heartwood in YHP after fungi and termite test was much lower than those of the sapwood in YHP. Furthermore, the highest mortality of termite was obtained from the heartwood of YHP. Consequently, it is clearly revealed that the heartwood of YHP has excellent durability against brown- and white-rot fungi and termite.

Biodegradation of 4-t-Octylphenol by Basidioradulum molare and Schizopora paradoxa and Estrogenecity Reduction of its Metabolites (옥틸페놀(4-t-Octylphenol)의 Basidioradulum molare와 Schizopora paradoxa에 의한 분해 및 에스트로겐성 저감효과)

  • Lee, Soo-Min;Ku, Bon-Wook;Lee, Jae-Won;Choi, Don-Ha;Jeung, Eui-Bae;Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.27-35
    • /
    • 2004
  • Recalcitrant 4-t-Octylphenol used as a surfactant was subjected to the biodegradation with wood rot fungi, Basidioradulum molare and Schizopora paradoxa. Two fungi were grown in the culture medium containing various concentrations of 4-t-Octylphenol in order to investigate their resistance against 4-t-octylphenol Schizopora paradoxa was reached to the full growth within 14 incubation days in the concentration of more than 200 ppm of 4-t-Octylphenol, while Basidioradulum molare showed the inhibitory mycelium growth as the concentration was increased Schizopora paradoxa and Basidioradulum molare biodegraded 95% and 36% of initial concentration of 4-t-Octylphenol at first incubation day, respectively. However, the biodegradation capability reached to more than 95% after 3 incubation days. During the biodegradation of 4-t-Octylphenol, the activity of manganese dependent peroxidase was induced by the addition of 4-t-Octylphenol in the culture medium of Schizopora paradoxa, but that of laccase was maximal before the addition. The reduction of estrogenecity was assayed by MCF-7 cell proliferation test and measurement of pS2 mRNA expression. The level of pS2 mRNA was decreased down to the level of baseline at first incubation day. Also, estrogenecity of 4-t-Ocrylphenol completely disappeared after treatment with supernatant by Schizopora paradoxa and Basidioradulum molare from first incubation day of culture down to the levels of vehicle.

Nondestructive Methods for the Detection of Internal Decay and the Vitality Measurement of Old-Giant Trees (노거수 활력 측정 및 내부 부후 검출을 위한 비파괴검사법)

  • Gao, Yuliang;Cha, Byeong Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.1
    • /
    • pp.144-157
    • /
    • 2009
  • Nondestructive methods to check the vitality of trees and to find out internal decay of old-giant trees include the use of electrical resistance, ultrasound transmission time, microdrilling, and infrared thermography etc. Among these, ultrasound transmission offers some advantages compared to others such as it is an entirely nondestructive detection method and it can be applied to very big trees. However, the ultrasound equipment is comparatively expensive and not broadly spread yet. On the other hand, Shigometer is versatile to be applied to check vitality of the tree and find out internal decay. Electrical conductivity of plant tissues is a very useful characteristics to determine the vitality and internal decay of trees. Electrical resistance of cambial area tells about the vitality of a tree and electrical resistance of heartwood reveals discoloration or decay of it. For determination of the vitality of the tree, the standard equation for calibration of measured electrical resistances should be developed by measuring and analyzing electrical resistance from at least 30-40 trees of the same species with that tree. All the factors, especially tree species, diameter of the stem, and temperature, which can altered the electrical resistance of trees, should be taken into consideration in the development of the equation. If the standard equation is developed for old-giant trees that we should conserve, it will be very useful. In addition, periodical and continued measuring of a certain tree will help to determine the condition of the tree by comparing the measurement with accumulated data of the tree. Measuring electrical resistance of wood might not require the standard equation. But it also needs to check electrical resistance of sound wood of the same tree species. If the stems that should be examined is thicker than 40cm, it is better to use the ultrasound measurement combined to Shigometer.

A Study on Interior Flooring Materials for Safe Elderly Nursing Home Environment (안전한 노인요양시설 환경을 위한 실내 바닥마감재에 관한 연구)

  • Chung, Miryum
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.19-26
    • /
    • 2014
  • The number of elderly who wants to access to Nursing Homes (NH) will increase due to the rapid aging society and domestic changes. Those who move into NH expect 24/7 care service in safe environment. Providing space free from danger, especially from fall, for the frail elderly is essential. The purpose of this study is to categorize performance needs of flooring materials in the aspect of safety, and analyze materials so that adequate ones for each space in NH can be suggested. Performance needs are as follows; slip resistance (dry/wet), fire resistance, resilience, water resistance, soil retardant, anti-bacterial, gloss, sound absorbtion. maintenance, durability, ease replacement, color and pattern variety, visual and tactual texture, tactile warmth, IAQ, sustainable material (before use), impact to nature (after use). They are categorized under function, economy, sensibility and sustainability. It was found that there are better materials than common ones that has been used repeatedly in NHs, such as vinyl sheets and VCT. In overall, Cork flooring and nylon carpet met all four categories, followed by wool carpet, rubber and linoleum. For bedroom, wood flooring, Cork, rubber, wool carpet, nylon carpets were suggested. In bathroom with shower, rubber, vinyl sheet and porcelain tiles were safe materials. As living/dining room and corridor floors, wool carpet, nylon carpet, cork flooring would be excellent as they are resilient and durable. The result of this paper can be used by both NH managers and material companies, resulting better quality of life of the elderly by providing safe environment.

Genetic Transformation of Irpex lacterus and Phlebia tremellosa to an Antibiotic Resistance (아교버섯과 기계충버섯의 형질전환)

  • Kim, Yun-Jung;Kim, Myung-Kil;Song, Hong-Gyu;Choi, Hyoung-T.
    • Korean Journal of Microbiology
    • /
    • v.43 no.2
    • /
    • pp.147-149
    • /
    • 2007
  • White-rot fungi which degrade lignin can also degrade diverse recalcitrant compounds such as polymeric dyes, explosives, pesticides, and endocrine disrupting chemicals. Lignin degrading enzymes are involved in the degradation reactions, and introduction of foreign genes into a white-rot fungus is required in order to increase the degrading capacity. Genetic transformation experiment has been carried out in Irpex lacteus and Phlebia tremellosa to an antibiotic resistance. The transformation yields were 50-70 transformants/${\mu}g$ DNA and 15-25 transformants/${\mu}g$ DNA in I. lacteus and P. tremellosa, respectively. The stable replication of the plasmid was confirmed by PCR using the plasmid-specific primers, and many mutants were generated during this integration in both fungi.

Effect of Properties of Fiber and Mineral Filler on Aging of Archival Documents (재료적 특성(섬유 및 금속)이 종이 기록물의 열화도에 미치는 영향)

  • Shin, Joung-Soon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.3
    • /
    • pp.13-21
    • /
    • 2012
  • This study was carried out to evaluate the stability of archival documents produced using papers. The properties of archival documents depend on the type of fillers of papers that are used such as fiber, non cellulose fiber, and mineral. The physio-chemical characteristics of archival documents were analyzed by employing acid hydrolysis against cellulose fiber substances. Fibers of Korean hand-made (Hanji), flex, and cotten papers showed higher pH and the degree of polymerization (DP) than wood fiber and mechanical fiber. Mechanical pulp containing 12.8% of lignin showed the greatest decrease of DP due to acid hydrolysis, and this resulted in increase of degree of aging. The filler found to clay and talc did not contain metal such as $Fe^{+2}$, $Fe^{+3}$, and $Cu^{+2}$. The alkaline metals such as Mg, Ca, and Ti showed greater resistance to acid hydrolysis.

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

The Study on Characteristics for Thermal Aging of the Layer Insulation in Transformers (변압기 층간 절연지의 열열화 특성 평가에 관한 연구)

  • 이병성;송일근;김동명;박동배;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.406-409
    • /
    • 2002
  • The primary insulation system used in an oil-filled transformer is Kraft paper, wood, porcelain and, of course, oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. These insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF