• Title/Summary/Keyword: wiring

Search Result 524, Processing Time 0.033 seconds

A Study on Properties on High Temperature Sintering Gravure Off-set Ag Paste (고온 소결형 그라비어 오프셋용 Ag 페이스트의 물성 연구)

  • Park, Chang-Won;HwangBo, Hyuck;Cho, Jung-Woo;Nam, Su-Yong
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.2
    • /
    • pp.71-82
    • /
    • 2011
  • Electronic display markets has been developed. The cathode ray tube of brown form recently celebrated their 100th by first display. Also LCD of flat form recently celebrated their 25th by second display and it has advantage of small volume, lower consumption power. But FPD has problem that is property of brittle and noncarrying by glass substrate. Therefore the arrival of portable electronics devices has put an increasing premium on durable, lightweight and inexpensive display components. It is flexible display by third display. Also electronics field such as printed wiring board, RFID, membrane switch prefer flexible display. The conductive pattern can be used mostly in field of electronic displays and electronics. This manufacture of conductive pattern in present used is screen printing. The the conductive pattern. It has advantages of flexibility, high conductivity, drying in low temperature, good conductivity. screen printing has problem that is low productivity and use not flexible substrate because of high fire temperature. This study was developed novel method to form the conductive pattern. It has advantages of flexibility, high conductivity, drying in low temperature, good conductivity.

Development of a Body Network System with GSEK/VDX Standards and CAN Protocol (OSEK/VDX 표준과 CAN 프로토콜을 사용한 차체 네트웍 시스템 개발)

  • 신민석;이우택;선우명호;한석영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.175-180
    • /
    • 2002
  • In order to satisfy the requirements of time reduction and cost saving for development of electronic control systems(ECU) in automotive industry, the applications of a standardized real-time operating system(RTOS) and a communication protocol to ECUs are increased. In this study, a body control module(BCM) that employs OSEK/VDX(open system and corresponding interfaces for automotive electronics/vehicle distributed executive) OS tour the RTOS and a controller area network(CAN) fur the communication protocol is designed, and the performances of the system are evaluated. The BCM controls doors, mirrors, and windows of the vehicle through the in-vehicle network. To identify all the transmitted and received control messages, a PC connected with the CAN communication protocol behaves as a CAN bus emulator. The control system based upon in-vehicle network improves the system stability and reduces the number of wiring harness. Furthermore it is easy to maintain and simple to add new features because the system is designed based on the standards of RTOS and communication protocol.

A Study on the Analysis and Limitations of the Same Phase Identification Under 3-Phase Unbalanced Constant Current Loads (3상 불평형 정전류 부하 조건에서의 동 위상 판별에 대한 분석 및 한계에 관한 연구)

  • Byun, Hee-Jung;Shon, Su-Goog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.38-46
    • /
    • 2012
  • In this paper, the necessity for the identification of the absolute phase value is introduced and analyzed for a particular conductor line of a 3-phase type distribution network and the recent methods are also introduced. For the determination of the exact phase value for a specific point in the line, as compared with the phase reference point, the measured phase value must be within a range of ${\pm}60[^{\circ}]$. However, the phase of a particular point can fluctuate depending on the line constant, transformer wiring method, line length, line amperage, etc. A theoretical formulation such as Simulink modeling and analysis for a distribution network are conducted for the identification of phase at a specific point in the line. In particular, through evaluating the effects of unbalanced current loads at the time of determination of the phase value, the limitations of the present method for the determination of phases is described.

Analysis of Vehicle Fire Accident Caused by Defect of Optionally Established Equipment (부가적으로 설치된 장치 결함으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.40-46
    • /
    • 2014
  • This paper deal with due to the additional equipment established on the vehicle fire accident cases. Recently, vehicle was recognized as other living spaces and it was increasing installation of additional devices such as a black box, multivision, additional battery and so on. However, these additional devices were established on the vehicle by non-specialists such as the general public user or manufacturing and distributors of additional devices since the vehicle factory. Resulting from the additional equipments due to installation errors in these additional equipments connected to the electrical wiring insulation damage or electrical breakdown occurs, and finally leading to a fire caused by the additional equipments. Therefore, additional equipment established on the vehicle due to a fire in order to prevent accidents during the manufacturing process of these devices are installed. If not installed unless the manufacturing process, the installation of additional equipments established by professional who knows the vehicle structure that will be able to prevent the fire.

Modeling and Voltage Variation Simulation of a Permanent Magnetic Synchronous Generator Wind Turbine Systems (영구자석 동기형 풍력발전시스템 모델링 및 전압변동 시뮬레이션)

  • Kim, Hong-Woo;An, Hae-Joon;Jang, Gil-Soo;Kim, Sung-Soo;Ko, Hee-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.116-123
    • /
    • 2009
  • This study performs modelling and simulation of permanent magnetic synchronous generator wind turbine by using Matlab & Simulink. In simulation, change of wind velocity, change of load, and voltage decrease of infinite bus are performed. Through such simulation, different with wiring system that there is only existing load, this study can confirm problems and voltage changing characteristics, which can occur in distributed electric power that load and electric power is mixed and operated, especially, in interconnecting with wind power generation.

Antenna sensor skin for fatigue crack detection and monitoring

  • Deshmukh, Srikar;Xu, Xiang;Mohammad, Irshad;Huang, Haiying
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.93-105
    • /
    • 2011
  • This paper presents a flexible low-profile antenna sensor for fatigue crack detection and monitoring. The sensor was inspired by the sense of pain in bio-systems as a protection mechanism. Because the antenna sensor does not need wiring for power supply or data transmission, it is an ideal candidate as sensing elements for the implementation of engineering sensor skins with a dense sensor distribution. Based on the principle of microstrip patch antenna, the antenna sensor is essentially an electromagnetic cavity that radiates at certain resonant frequencies. By implementing a metallic structure as the ground plane of the antenna sensor, crack development in the metallic structure due to fatigue loading can be detected from the resonant frequency shift of the antenna sensor. A monostatic microwave radar system was developed to interrogate the antenna sensor remotely. Fabrication and characterization of the antenna sensor for crack monitoring as well as the implementation of the remote interrogation system are presented.

Development of the Insufflator for Endoscopic Surgery using the Fluidic System in Printed Circuit Board (유공압 부품이 내장된 인쇄회로기판을 활용한 내시경 수술용 기복기의 개발)

  • Lee, Hee-Nam;Kim, In-Young;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.32-36
    • /
    • 2011
  • The insufflators in endoscopic surgery supply carbon dioxide to make the air-filled cavity in the abdomen. It contains many kinds of pneumatic and electronic parts and they are connected with the air tubes and electrical wires. The printed circuit boards (PCB) perform wiring, holding and cooling tasks in electronic systems. In this study, the PCB is used as the air channel for insufflators to decrease the cost, volume, and the malfunction according to aging of the device. Three layers of PCB made of FR4 are combined with prepreg as adhesive which has the internal airway channel according to the design. By mounting the pressure sensors and valves, the PCB based fluidic system is implemented. After calibration of flow sensor, the flow rate of the gas also can be measured. The climate test, temperature test, and biocompatibility test showed this idea can be used in insufflators for laparoscopic surgery.

A Study on PV System Output Changes by PV Array Installation Position and Mount Angle Change (태양광 어레이 설치 위치 및 각도변경 전후의 태양광 발전 시스템의 출력 변화에 관한 연구)

  • Yoon, Jeong-Phil;Cha, In-Su;Choi, Jeong-Sik;Kim, Dong-Mook;Park, Jong Bock;Ha, Min Ho;Kim, Won Bae
    • Current Photovoltaic Research
    • /
    • v.2 no.4
    • /
    • pp.189-194
    • /
    • 2014
  • In this paper, We have simulated the output variation of the PV arrays installation with position & angle change. The existing 3 solar array system are $43^{\circ}$ southeast and each of the mounting angle is $17^{\circ}$. The PV output power is 240 kW. The composite studied systems in this paper arrays altered 2 PV array among 3 PV array system- the output 144kW. We simulated this system using Solar Pro ver.4.1. The simulation conditions are southwest $43^{\circ}/array$, mount angle $27^{\circ}/array$. Because the southeast have shadow effect-higher mountain The purpose of southwest $43^{\circ}$ is reduce the shadow effect. The simulation results of the suggestion design algorithm compared to 1,590 kWh/year output is increased with the southeast.

The Analysis of Present State and Improvement Way according to the Installation of Electric or Plumbing Equipments of Traditional Folk Houses - Focused on Yongdong, Gangwon Province - (전통민가의 전기 및 설비시설 설치에 따른 실태분석과 개선방안 - 강원영동지역을 중심으로 -)

  • Jin, Jae Hyung;Choi, Jang Soon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.3
    • /
    • pp.25-32
    • /
    • 2012
  • Traditional folk houses in Yongdong, Gangwon province play important roles in figuring out natural, human, and social value in the past time including housing life. However, according to the introduction of electric or plumbing equipment in housing life styles, many conventional architectures have been changed by installations of new electric or plumbing equipment, convenience facilities, and etc. Therefore, this study aims to make basic data to prepare for standardized installations of the electric or plumbing equipment, and convenience facilities by surveying of the present installation status, such as electric lights, outlets, switches, wiring, pipe laying, or monitoring devices for crime, disaster prevention facilities, and home appliances etc. Additionally, this paper is related to the meaning and usage, which are connected with the electric or plumbing equipment installations of the traditional folk houses to be prepare for the proper solutions between preservations of the original form and convenient lives for residents.

A New Low-Cost Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System (3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저가형 능동전력필터)

  • 장민수;최세완;김기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.359-365
    • /
    • 2002
  • Three-phase four-wire electrical distribution systems have been widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads, the neutral conductor carries excessive harmonic currents resulting in wiring failure of the neutral conductor, overloading of the distribution transformer and a voltage drop between the neutral and the ground. This paper proposes a reduced rating active power filter to suppress neutral current harmonics in three-phase four-wire electrical distribution systems. The proposed system is simple in control and the VA rating of the inverter could be significantly reduced since only the fundamental current due to unbalanced loading flows through the inverter switch. The experimental results on a prototype validate the proposed control approach.