• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.03 seconds

Fault Diagnosis Method of Voltage Sensor in 3-phase AC/DC PWM Converters

  • Kim, Hyung-Seop;Im, Won-Sang;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.384-390
    • /
    • 2012
  • This paper proposes a fault diagnosis method of the line-to-line voltage sensors in 3-phase AC/DC pulse width modulation (PWM) converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid voltages for controlling the 3-phase AC/DC PWM converters. If the line-to-line voltage sensors are mismeasured by various faults, the voltage sensors can obtain wrong information of the grid voltage. It has an adverse effect on the control of the converter. Therefore, the converter causes the unbalance input AC current and the DC-link voltage ripple in the 3-phase AC/DC PWM converter. Hence, fast fault detection and fault tolerant control are needed. In this paper, the fault diagnosis method is proposed and verified through simulations and experiments.

A Study on the Design and Modeling of PWM Fuel Metering Unit for Miniature Turbo Engines (초소형 터보엔진용 PWM 연료조절장치의 설계 및 모델링에 관한 연구)

  • Joo Sang-Hyun;Choi Ho-Jin;Park Jong-Seung;Lim Jin-Shik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • A fuel metering unit using PWM(Pulse Width Modulated) solenoid valve has some advantages such as low cost, small size and simple structure. The mathematical model and its experimental rig of the fuel metering unit using PWM solenoid valve and CPDV(Constant Pressure Drop Valve) for miniature turbo engines were constructed. As the results of simulation, some major parameters which have dominant effects on the performance were found. And the experimental results verified the validity of established model by showing the good agreement with the numerical simulation results. Hence, this system modeling could be used effectively in the actual development of a PWM fuel control system.

A Study on the PWN Inverter for the Design of UPS (무정전 전원(UPS)설계를 위한 PWN 인버터에 관한 연구)

  • 이성백;구용회;이종규
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.2
    • /
    • pp.59-63
    • /
    • 1988
  • In a fixed AC power source the PWM techniques were used to vary the voltage and the fundamental frequency. The conventional PWM techniques due to the problem of commutation number and filter size have been studied the PWM output waveforms which applied the motor drive. However in this paper, the carrier frequency with sinusoidal PWM waveform is modulated from 10(KHz) to 45(KHz) using termination devices with high - speed switching capacity and applying LPF(Low Pass Filter) with small capacity to output of inverter and the PAM(Pulse Amplitude Modulation)is obtained. Considering the property of the speed and the control, the sinusoidal PWM control circuit was composed of the microprocessor and analog circuit. In experment result, the system properties are study on the sinusoidal voltage waveform with modulation index changing from 0.6 to 1.0.

  • PDF

Digital Implementation of PWM Techniques for Two-phase Eight-switch Inverter fed Brushless DC Motor Drives

  • Lin, Hai;You, Yong-Min;Cheon, Sung-Rock;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.295-303
    • /
    • 2013
  • This paper reports an investigation of pulse width modulation (PWM) techniques for two-phase brushless DC (BLDC) motors fed by a two-phase eight-switch inverter in a fan application. The three-phase BLDC motor is widely applied in industry; however, a lower-cost two-phase BLDC motor and drive circuit has been greatly in demand in recent years. In this paper, we introduce a mathematical model of the two-phase BLDC motor with sinusoidal back electromotive forces (EMFs) based on traditional three-phase BLDC motors. To simplify the drive algorithm and speed up its application, we analyze the principle of block commutation for a two-phase BLDC motor drive in the 180-electrical-degree conduction mode, and we further propose five PWM schemes to improve the commutation performance of the two-phase BLDC drive. The effectiveness of the proposed PWM methods is verified through experiments.

Nd:YAG laser firmware Design under RTOS operation (RTOS(Real Time Operation System) 환경하의 Nd:YAG 레이저 Firmware 설계)

  • Kim, B.G.;Kim, W.Y.;Park, G.R.;Moon, D.S.;Hong, J.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2107-2109
    • /
    • 2000
  • A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate This system is controlled by microprocessor and allows to replace an expensive condenser for high frequency to cheap one for low frequency. In addition, The microcontroller monitors the flow of cooling water, short circuit. and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now.

  • PDF

Spray Characteristics of a Modulated Liquid Jet through 2nd Pulsed Control (2차 가진 제어 변조분사 특성 및 액체제트의 분무특성)

  • Kang, Young-Su;Lee, In-Chul;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.672-675
    • /
    • 2010
  • Spray characteristics for the modulation with a pulsed spray in low-frequency region were investigted by performing with additional internal pulsed injection. The 1st perturbative flow was generated by rotating-type pulsed device and the 2nd pulse source generated by the magnetic valve was used to modulate the 1st flow. A pattern of the modulated spray was observed through FFT result and visualization. In case of modulated spray with the 2nd pulse control, the width of up and down motion of the modulated spray is smaller than that of the spray without the 2nd pulse. Also, the depth of penetration of the down stream is higher than that of spray without the 2nd pulse.

  • PDF

Flow Mechanism around Air Flow Sensor of Electronic Control Engine (전자제어 엔진의 공기유량센서 유동구조 연구)

  • 이종춘;황성만;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.486-493
    • /
    • 2000
  • Flow mechanism around air flow sensor of electronic control engine, especially Karman vortex type, was investigated experimentally. The two-dimensional flow characteristics in the intermediate wake region behind a triangular vortex-generator respectively apex forward facing, apex backward facing and vertical flat plates following after apex forward facing(i.e vortex-flowmeter) were investigated at Reynolods number of $ReH=1.4\times10^4$; H is the width of a triangular vortex-generator. The vortex shedding frequency for wide Reynolds number from $7\times10^3$ to $2.1\times10^4$ was also surveyed. The velocity component was measured by X-type hot wire anemometer at 8H downstream from the bluff body. The coherent structure of the intermediate wake behind a bluff body was obtained by conditional phase average technique. As a result, it was verified that the vertical flat plates following after apex forward triangular vortex-generator make not only more linear relation between free stream velocity and vortex shedding frequency but also more periodic vortex in the vicinity of the center of wake.

  • PDF

Calibration of Double-skin Simulation Model Depending on Configuration And Impact of Local Weather Information (이중외피 형상에 따른 모델 보정과 local 기상 정보의 필요성)

  • Yoon, Kyeong-Soo;Kim, Deuk-Woo;Lee, Keon-Ho;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.142-147
    • /
    • 2009
  • In order to achieve performance assessment and optimal control of a double-skin system, an accurate simulation model is required. In the previous study, a lumped simulation model of such system was developed. As a follow-up of the previous research, the first objective of this paper is to investigate how the mathematical model should be calibrated according to system configuration(cavity width, depth, height, airflow pattern, local environment, etc.). And the second objective of this study is to discuss the effect of local weather information. In conclusion, this paper describes that the model should be recalibrated according to configuration. And it is necessary to have local weather information for accurate prediction and optimal control of the system.

  • PDF

Effect of CO Intoxication on the Pulmonary Surfactant in Rabbits (일산화탄소중독(一酸化炭素中毒)이 가토(家兎) 폐포표면활성물질(肺胞表面活性物質)에 미치는 영향(影響))

  • Choo, Young-Eun;Lee, Suck-Kang
    • The Korean Journal of Physiology
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 1972
  • In order to observe a possible effect of CO intoxication on the activities of surfactant, the rabbit war exposed either to 0.1, 0.2 and 0.4% CO gas for two to six hours or 0. 1% CO gas for two hours daily for 1, 3 and 5 days, and the lung extract was prepared. The tension-area diagram of the lung extract was recorded automatically using the modified Langmuir-wilhelmy balance with a synchronized recording system, and the results were compared with control (i. e. : non-CO gas exposed normal rabbits). The results obtained are summarized as follows: 1. The maximal and minimal surface tensions, width of the tension-area diagram at the surface area of 40% in lung extract, and stability index of the normal rabbit lung extracts were $31.6{\pm}3.11\;dynes/cm,\;8.2{\pm}0.56\;dynes/cm,\;21.4{\pm}4.40dynes/cm\;and\;1.12{\pm}0.22$, respectively. 2. The activities of surfactant in the CO gas exposed group did not show any significant change from the control. 3. The above results suggest that CO gas produced no noticeable effect on the surfactant system of the lung.

  • PDF

Performance Improvement of Moving Coil Type Linear Oscillatory Actuator Considering Asymmetric Magnetic Circuit (자기회로 불평형을 고려한 가동 코일형 리니어 진동 엑츄에이터의 운전특성 개선)

  • Kim, Duk-Hyun;Eum, Sang-Joon;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.713-719
    • /
    • 2000
  • This paper presents an approach toward improving the performance of Moving Coil Type Linear Oscillatory Actuator (MC-LOA) with the application of Finite Element Method (FEM) to a simple control system. MC-LOA has an unbalanced magnetic circuit due to its asymmetric structure and there is a different flux distribution on the air-gap along the current direction. The interaction driven by two fluxes between the Permanent Magnet (PM) and the current causes the unbalanced thrust and interferes with the proper oscillation of MC-LOA. In order to solve the above problems and improve the driving performance, it is necessary to analyze the rate of the unbalanced thrust according to the current direction by using FEM. Then, the analysis results are used to determine the input currents for both directions. Controlling the input currents can be easily achieved by a simple control system, such as Pulse Width Modulation (PWM), without complex units. The validity of the approach is verified by the experimental results.

  • PDF