• 제목/요약/키워드: water-tube

검색결과 1,459건 처리시간 0.03초

말기 암 환자의 장폐색성 복통에 대한 침구 및 족삼리 전침 치험 2례 (Acupuncture, ST-36 Electroacupuncture and Moxa Treatment of Abdominal Pain due to Bowel Obstruction in Cancer Patients : Case Report)

  • 김소연;최준용;박성하;권정남;이인;홍진우;한창우
    • 동의생리병리학회지
    • /
    • 제28권2호
    • /
    • pp.238-242
    • /
    • 2014
  • Here we described 2 cancer patients treated by acupuncture for abdominal pain as a complication of bowel obstruction. The patient 1, 43-year-old man was treated with surgery, radiotherapy and chemotherapy for rectal cancer. Two years after surgery, he complained of acute abdominal pain due to small bowel adhesion band. Bowel obstruction and symptoms were not improved by conservative therapy like as fasting, keeping Levin tube, and fluid therapy. 4 months later, he could eat a little rice water, but ileus and abdominal pain persisted despite of applying opiod drug and patch. Got started on acupuncture, electroacupuncture(ST-36) and moxa treatment, pain was relived gradually. He could stop opioids 1 month later and ileus was improved after acupuncture therapy for 2 months. The patient 2, 65-year-old woman got hepatectomy, cholecystectomy, and chemotherapy with cholangiocarcinoma. 6 months after surgery, she got laparotomy again for biopsy of new mass around ascending colon. She started eating after gas passing, but felt abdominal distension. Diffuse paralytic ileus was diagnosed by abdominal X-ray, and she got started conservative therapy. During ST-36 electroacupuncture therapy, symptoms like abdominal pain and distension were improved and could stop opiod patch. But eating aggravated ileus again and clinical finding of mechanical bowel obstruction was appeared. Based on these cases, acupuncture and moxa therapy could be helpful for improving abdominal pain and ileus, but possibility of malignant bowel obstruction should be considered especially in cancer patients.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구 (A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System)

  • 배명환;정광호;박성범
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.263-273
    • /
    • 2016
  • 자연순환식 압입 송풍식 수관보일러에 FGR시스템을 설치하여 보일러 부하 및 공기량 댐퍼개도를 파라미터로 해서 FGR률에 따른 성능 및 배기 배출물에 미치는 재순환 배기의 영향을 조사하였다. 본 연구의 목적은 $NO_x$ 배출물을 저감시키기 위하여 동력플랜트 보일러에 FGR시스템을 적용하는 것이다. 연소를 활성화시키기 위해 0 ~ 20%의 연소용 공기를 화염 내에 공급한다. 공기상자 상부에 설치된 2단 연소시스템의 흡입댐퍼를 $0^{\circ}{\sim}90^{\circ}$ 사이에서 레버를 조작하여 열면, 버너로 공급되는 연소용 공기가 변화된다. 증발률당의 연료소비율은 FGR률의 증가에 따라 증가 혹은 감소의 명확한 경향을 나타내지 않았고, 동일 공기량 댐퍼개도에서는 FGR률이 증가할수록, 또한, 보일러 부하가 감소할수록 $NO_x$ 배출물이 감소되었다. 매연 배출물은 전기 집진기에서 86.7%의 포집효율로 매연이 제거되었기 때문에, 보일러 부하, 공기량 댐퍼 개도 및 FGR률의 운전조건에 관계없이 극소량의 매연이 배출되었다.

Expectation Maximization (EM)과 Least Mean Square(LMS) algorithm을 이용하여 초음파 비파괴검사 신호의 분류를 하기 위한 새로운 접근법 (A novel approach to the classification of ultrasonic NDE signals using the Expectation Maximization(EM) and Least Mean Square(LMS) algorithms)

  • Daewon Kim
    • 융합신호처리학회논문지
    • /
    • 제4권1호
    • /
    • pp.15-26
    • /
    • 2003
  • 초음파 검사 방법은 여러 가지 물질들의 흠집이나 틈새, 그리고 티끌 등을 감지해내는데 널리 쓰이고 있다. 그 중 초음파 신호를 분석하는 절차는 전체의 신호처리 과정에서 아주 중요한 역할을 담당하고 있다. 많은 초음파 신호처리와 신호분류의 방법들이 제기 되었는데 그 중 가장 널리 쓰이는 방법은 신호들의 특징 공간상에서 그 특정의 성분들을 추출해내고 그 후 신경망 네트웍을 통한 분류 방법을 이용하여 초음파 신호들을 구별해 내는 방법이다. 이 논문은 기존의 신호 분류 체계와는 다른 대체 신호 분류법을 제시하고 있는데 이것은 최소 평균 제곱 (LMS) 알고리즘을 이용하여 핵 전력 발전소에서 쓰이는 증기 발생기 튜브로부터 감지되어진 초음파 비파괴 검사 신호 (ultrasonic nondestructive evaluation signal) 을 분류해내는데 쓰일 수가 있다 이 초음파 비파괴 검사 신호는 튜브내의 흠집이나 틈새로부터 감지되어진 신호일수도 있고 또는 튜브내의 침전물에 의해서 발생된 신호일 수도 있는데 이 두가지 신호는 매우 유사하기 때문에 반드시 분류를 해내어 침전물에 의한 신호일 경우는 무방하지만 흠집이나 갈라진 틈새에서 나오는 신호일 경우는 더 이상의 오염이나 사고 등을 방지하기 위해 수리 또는 교체 등의 후속 조치로 이어져야 한다. 이러한 절차를 밟기 위하여 증기 발생기 튜브의 내부에서의 초음파 센서로부터 증기 발생기 튜브 사이의 거리를 측정하는데 모델링 기법에 기반한 deconvolution 방법이 제시되었고 여기서 나온 결과가 정리, 분석되었다 이 방법은 space alternating generalized expectation maximization (SAGE) 알고리즘을 이차원 미분 파라미터인 Hessian의 사용으로 인하여 수렴 속도가 빠른 Newton-Raphson 알고리즘과 함께 병행 사용하여 초음파 신호의 초점 도달 시간과 그 크기를 측정하여 초점 도달 거리에 따라 두 종류의 신호를 분류, 차별화 하는 기법이다. 이 알고리즘을 이용한 접근법으로 얻어진 결과가 흠집이나 틈새로부터 나온 신호일 경우와 퇴적물에 의해 나온 신호일 경우로 정리, 분류되었고 적절한 분류 효과를 보인 결과가 이 논문에 제시되었다.

  • PDF

액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발 (Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구 (A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste)

  • 고성규;조용균;이영신
    • 유기물자원화
    • /
    • 제20권4호
    • /
    • pp.97-105
    • /
    • 2012
  • 본 연구는 음식물류 폐기물의 처리과정에서 발생하는 음식물류 폐수를 생활폐기물 소각시설에서 생활폐기물과 음식물류폐수를 혼합하여 소각처리 방법과 소각시 음식물류 폐수를 이용한 질소산화물 제거 및 배출가스의 영향등을 조사하였다. 해양투기용으로 발생된 음식물류폐기물 폐수는 성상이 94-96%의 함수율을 갖고 있다. 음식물류폐기물 폐수를 주입하였을 때 소각로 출구 온도는 $897^{\circ}C$이였으며, 평상시는 $925^{\circ}C$로 약 $28^{\circ}C$도 떨어졌다. 음식물류폐기물 폐수를 각각 $200{\ell}/hr$, $300{\ell}/hr$ 투입시 질소산화물의 평균배출농도는 각각 50ppm, 46ppm 이었다. 연관식 폐열보일러는 음식물류 폐수의 투입량이 많을수록 튜브 막힘 현상이 있었으며, 막힘 튜브는 압축공기를 이용한 튜브 청소로 원상태를 유지 할 수 있어 연속적 소각에는 방해가 되지 않았다. 유기성 폐기물인 음식물류 폐수의 자원화 처리방법과 더불어 기존 소각시설을 이용한 소각처리가 육상처리의 한 방법으로 자리매김 할 수 있으며, 소각시 배출가스의 질소산화물이 제거됨으로써 질소산화물 제거용 암모니아, 요소수 등 화학약품비용 절감하는 효과도 있는 것으로 나타났다.

몬테칼로 기법을 이용한 CBCT의 광자선 특성 및 선량 분석 (Analysis of Photon Characteristics and Absorbed Dose with Cone Beam Computed Tomography (CBCT) using Monte Carlo Method)

  • 김종보;김정훈;박은태
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.161-169
    • /
    • 2017
  • 방사선 치료 시 자세 확인 촬영을 목적으로 3차원 영상 획득이 가능한 콘빔씨티 촬영이 많이 이용되고 있다. 본 연구에서는 몬테칼로 기법을 이용한 모의실험을 통해 콘빔씨티 촬영 시 피폭선량을 정략적으로 분석하고 표준화된 데이터를 제시하고자 한다. 실험은 MCNPX(ver. 2.5.0)를 이용하였으며, 먼저 콘빔씨티를 모사한 후 광자선 스펙트럼을 분석하였다. 그리고 물 팬텀을 모사하여 깊이별 심부선량 백분율과 흡수선량을 측정하였다. 광자선 스펙트럼을 분석한 결과, 관전압 80 ~ 120 kVp 에서 평균 에너지는 조건에 따라 25.7 ~ 52.6 keV로 나타났으며 특성X선 에너지는 9, 60, 68, 70 keV로 나타났다. 물 팬텀을 사용하여 심부선량 백분율을 측정한 결과 표면에서 최대선량이 나타났으며 깊이가 깊어질수록 감소하는 것으로 나타났다. 흡수선량 또한 깊이가 증가할수록 감소하였으며 팬텀 전체가 받는 흡수선량은 9.7 ~ 18.7 mGy로 나타났다. 이는 일반적으로 방사선 치료에 사용되는 주당 처방선량인 약 10Gy의 0.2%를 차지하는 선량이며 이는 치료효과에는 큰 영향을 미치지 않을 것으로 판단된다. 그러나 처방선량에 비해 미미한 수준일지라도 이를 간과해서는 안 될 것이다.

최대 추정 기법과 최소 평균 자승 알고리즘을 이용한 초음파 비파괴검사 신호 분류법 (Classification of Ultrasonic NDE Signals Using the Expectation Maximization (EM) and Least Mean Square (LMS) Algorithms)

  • 김대원
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.27-35
    • /
    • 2005
  • 초음파 검사 방법은 여러 가지 물질들의 흠집이나 틈새, 티끌 등을 감지해내는데 널리 쓰이고 있다. 그 중 초음파 신호를 분석하는 절차는 전체의 신호처리 과정에서 아주 중요한 역할을 담당하고 있다. 이 논문은 최소평균 제곱 (LMS) 알고리즘을 이용하여 핵 전력 발전소에서 쓰이는 증기 발생기 튜브로부터 감지된 초음파 비파괴검사 신호를 분류 해내는 것에 관한 것이다. 이 초음파 신호는 튜브내의 흠집이나 틈새로부터 감지된 신호일수도 있고 또는 튜브 내의 침전물에 의해서 발생된 신호일 수도 있는데 이 두 가지 신호는 매우 유사하기 때문에 반드시 분류를 해내어 침전물에 의한 신호일 경우는 무방하지만 흠집이나 갈라진 틈새에서 나오는 신호일 경우는 더 이상의 오염이나 사고 등을 방지하기 위해 수리 또는 교체 등의 후속 조치로 이어져야 한다. 이러한 절차를 밟기 위하여 증기 발생기 튜브의 내부에서의 초음파 센서로부터 증기 발생기 튜브 사이의 거리를 측정하는데 모델링 기법에 기반한 deconvolution 방법이 제시되었으며 이 방법은 space alternating generalized expectation maximization (SAGE) 알고리즘을 이차원 미분 파라미터인 Hessian의 사용으로 인하여 수렴 속도가 빠른 Newton-Raphson 알고리즘과 함께 병행 사용하여 초음파 신호의 초점 도달 시간과 그 크기를 측정하여 초점 도달 거리에 따라 두 종류의 신호를 분류, 차별화 하는 기법이다. 이 알고리즘을 이용하여 흠집이나 틈새로부터 나온 신호일 경우와 퇴적물에 의해 나온 신호일 경우로 분류되었고 그 결과가 이 논문에 제시되었다.

고분자 분산제 주입을 통한 철산화물(Magnetite, Fe3O4) 입자의 분산 안정성 향상 (Improvement in the Dispersion Stability of Iron Oxide (Magnetite, Fe3O4) Particles with Polymer Dispersant Inject)

  • 송근동;김문환;이용택;맹완영
    • 공업화학
    • /
    • 제24권6호
    • /
    • pp.656-662
    • /
    • 2013
  • 원자력발전소의 2차 계통수 중에 존재하는 철산화물(magnetite)은 열전달 튜브의 표면에 침착(fouling)되어 열전달 성능을 떨어뜨리거나 부식을 유발한다. 이와 같은 문제를 방지하기 위해, 원전 2차 계통수 중에 고분자 분산제(polymeric dispersant) 주입을 통해 철산화물의 분산 안정성 향상을 도모하는 연구를 수행하였다. 카르복실기(-COOH, carboxyl group)를 함유한 3종의 음 이온성 고분자(PAA, PMA, PAAMA)를 선정하였으며, 이들에 농도변화(1~1000 ppm)에 의한 마그네타이트 분산 특성을 평가하기 위해 침강시험, 투과율 측정, 입도 측정, 제타전위 측정을 수행하였다. 고분자 분산제는 수용액 중 철산화물 분산안정성에 큰 영향을 미쳤다. 분산제가 주입되면 분산 안정성이 향상되는 경향을 보였으나, 분산제 농도 증가에 따라 마그네타이트의 분산 안정성이 선형적으로 비례하여 증가하지 않았다. 이는 임계 분산제 농도 이상에서는 철산화물 사이의 응집(agglomeration)이 발생하기 때문인 것으로 사료된다. 분산안전성 향상 효과는 분산제-철산화물의 농도비(ppm, 분산제/마그네타이트)가 0.01~0.1 범위에서 현저하였다. 분산제 주입을 통한 철산화물 제거 효과를 최대화하기 위해서는 적용 환경 특성, 철산화물 농도, 분산제 농도 및 철산화물-분산제 농도비의 최적화가 필요한 것으로 판단된다.

Ferricyanide와 ferric chloride 혼합액을 사용한 Bisphenol A의 비색 정량법 개발 (Spectrophotometric Determination of Bisphenol A by Complexation with Ferricyanide and Ferric chloride solution)

  • 금은주;류희영;권기석;손호용
    • 생명과학회지
    • /
    • 제17권2호통권82호
    • /
    • pp.266-271
    • /
    • 2007
  • BPA는 플라스틱 가소제 및 폴리카보네이트 플라스틱 생산의 모노머로 광범위하게 사용되어 왔으며, 년간 세계적으로 640,000톤 이상이 생산되고 있다. 내분비장애활성을 가진 BPA는 수계 및 공업용수에서 흔히 발견되며, 이의 분석은 HPLC 및 GC 등 기기분석에 의존하고 있다. 그러나 본 연구에서는 환경 및 생활용품에 잔류하는 BPA를 신속, 정확하고, 경제적으로 분석할 수 있는 분광학적 정량방법을 개발하고자 하였으며, 이를 위해 $FeCl_3{\cdot}6H_2O$$K_3Fe(CN)_6$를 사용한 비색정량법을 확립하였다. 발색반응으로 생성된 청색화합물의 ${\lambda}max$ 및 반응특이성을 조사하였으며, 최적반응조건(시간, 온도, pH, 농도, 부피, 반응안전성)을 검토하였다. 확립된 발색반응조건에서 BPA에 대한 검량곡선(${\lambda}_{750}$=0.61 BPA $[{\mu}M]$+0.07155, $R^{2}$=0.992)을 얻었으며, 신규 확립된 비색정량법을 이용하여 토양, 수계 및 생활용품의 BPA 분석을 시도한 결과, HPLC 분석시스템과 유사한 결과를 얻을 수 있었다. 본 BPA 및 관련물질에 대한 비색정량법은, 기기분석에 비해 빠르고, 경제적이며, 대량의 시료를 일시에 취급할 수 있어 기기분석의 보완분석으로도 우수하며, BPA 분해산물은 발색반응을 나타내지 않아, 자연계로부터 BPA 분해균주 선별 등에 매우 유용하게 이용될 수 있다.