• Title/Summary/Keyword: water temperature increase

Search Result 2,306, Processing Time 0.026 seconds

Experimental study on the condensation of sonic steam in the underwater environment

  • Meng, Zhaoming;Zhang, Wei;Liu, Jiazhi;Yan, Ruihao;Shen, Geyu
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.987-995
    • /
    • 2019
  • Steam jet condensation is of great importance to pressure suppression containment and automatic depressurization system in nuclear power plant. In this paper, the condensation processes of sonic steam jet in a quiescent subcooled pool are recorded and analyzed, more precise understanding are got in direct contact condensation. Experiments are conducted at atmospheric pressure, and the steam is injected into the subcooled water pool through a vertical nozzle with the inner diameter of 10 mm, water temperature in the range of $25-60^{\circ}C$ and mass velocity in the range of $320-1080kg/m^2s$. Richardson number is calculated based on the conservation of momentum for single water jet and its values are in the range of 0.16-2.67. There is no thermal stratification observed in the water pool. Four condensation regimes are observed, including condensation oscillation, contraction, expansion-contraction and double expansion-contraction shapes. A condensation regime map is present based on steam mass velocity and water temperature. The dimensionless steam plume length increase with the increase of steam mass velocity and water temperature, and its values are in the range of 1.4-9.0. Condensation heat transfer coefficient decreases with the increase of steam mass velocity and water temperature, and its values are in the range of $1.44-3.65MW/m^2^{\circ}C$. New more accurate semi-empirical correlations for prediction of the dimensionless steam plume length and condensation heat transfer coefficient are proposed respectively. The discrepancy of predicted plume length is within ${\pm}10%$ for present experimental results and ${\pm}25%$ for previous researchers. The discrepancy of predicted condensation heat transfer coefficient is with ${\pm}12%$.

Numerical Simulation of the Water Temperature in the Al-Zour Area of Kuwait

  • Lee, Myung Eun;Kim, Gunwoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.334-343
    • /
    • 2019
  • The Al-Zour coastal area, located in southern Kuwait, is a region of concentrated industrial water use, seawater intake, and the outfall of existing power plants. The Al-Zour LNG import facility project is ongoing and there are two issues regarding the seawater temperature in this area that must be considered: variations in water temperature under local meteorology and an increase in water temperature due to the expansion of the thermal discharge of expanded power plant. MIKE 3 model was applied to simulate the water temperature from June to July, based on re-analysis data from the European Centre for Medium-Range Weather Forecasts (ECMWF) and the thermal discharge input from adjacent power plants. The annual water temperatures of two candidate locations of the seawater intake for the Al-Zour LNG re-gasification facility were measured in 2017 and compared to the numerical results. It was determined that the daily seawater temperature is mainly affected by thermal plume dispersion oscillating with the phase of the tidal currents. The regional meteorological conditions such as air temperature and tidal currents, also contributed a great deal to the prediction of seawater temperature.

Comparison on Dimension and Hydration Rate of Korean Kidney Beans (강낭콩의 품종에 따른 형태적 특성 및 침지중 수화속도의 비교)

  • 박선희;조은자
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.2
    • /
    • pp.286-292
    • /
    • 1995
  • Proximate composition, dimension, water uptake and volume increase rates of three cultivars of Korean kidney beans, Pink(PKB), Red(RKB) and White(WKB) were compared. Significant differences in the proximate composition and calorie were not observed among samples. Hull removed samples showed the lowest ash content and the highest calorie. The rates of water uptake increased as the soaking temperature increased from 10~4$0^{\circ}C$. The moisture gain of the kidney beans during soaking showed a similar pattern to volume increase. Water uptake and volume increase rates were in the decreasing order of PKB, RKB and WKB. Moisture and volume gains held a linear relation with the square root of soaking time regardless soaking temperatures. The activation energies of water uptake and volume increase were 3033~3087 and 3077~ 3161 kcal/mole, respectively. The log time to reach a fixed moisture content showed a linear relation with soaking temperature regardless soaking temperatures. The z-values calculated from weight and volume changes decreased in proportions to the increase of hydration. The z-values of weight and volume to reach 50% hydration were 50.5~56.6$^{\circ}C$ and 48.4~61.2$^{\circ}C$, respectively.

  • PDF

A Study on the Performance of Ground Source Heat Pump System (지중열원 열펌프시스템의 성능해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.69-76
    • /
    • 2005
  • The performance of water-to-water heat pump system coupled with the ground source vertical heat exchanger is presented in this paper. The CAP program of Florida Heat Pump Co. is used to predict the heat pump performances while the EED program calculates the borehole fluid temperature. It is shown that COPH increases with decreasing the temperature of output water for the operation of heating mode and COPR increases with increasing temperature of output water for the operation of cooling mode. The value of specific heat extraction rate must be moderate to insure the reasonable installation cost of borehole system. With $1^{\circ}C$decrease of $T_{wo}$ the average COPH increase is estimated as about $0.06/^{\circ}C$(for $T_{wo}\;=\;45{\sim}60^{\circ}C$ range) while with $1^{\circ}C$ increase of $T_{wo}$ the estimation of COPR increase is about $0.13/^{\circ}C$(for $T_{wo}\;= \;5{\sim}11^{\circ}C$ range) at the specific heat extraction rate of 30W/m.

Effect of Water Impingement Conditions on the Degradation of Epoxy Coatings in Tap Water

  • Kim, D.H.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.327-339
    • /
    • 2022
  • The water-jet technique started by Bridgman can cut metal and alloys without harmful gas and fume. However, while this technique is convenient to cut metals and alloys, in the case of coated pipe, water jet induces the degradation of coatings on the pipes, and may facilitate structural failure, leakage, and loss of products. While there are many reports on the effect of water jet on cut metals and the damage of metallic materials, research on the effect of water impingement on the epoxy coatings has been little studied. In this work, we therefore control the velocity of water jet, distance between nozzle and specimen, and water temperature, and discuss the effect of water impingement on the epoxy coatings. Increasing water velocity and water temperature and reducing nozzle distance increased the degradation rates of three epoxy coatings were increased. Among three test parameters - water velocity, nozzle distance and water temperature, water temperature was relatively effective to increase the degradation rate of epoxy coatings.

Effect of Temperature and Water Immersion on Strength Properties of Spot Welded Zincked Steel Plates (점용접 아연도금강판의 강도특성에 미치는 온도 및 침수의 영향)

  • Seo, Do-Won;Choi, Jun-Yong;Lim, Jae-Kyoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1864-1870
    • /
    • 2004
  • A spot welded structures have an influence on a diverse climatic situation, for instance temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase. But spot welded structures strength is affected by humidity and environment temperature. Therefore, it is important to evaluate effect of temperature and water immersion on strength properties of spot welded part. In this study, the strength distribution of spot welded plates is evaluated the environmental temperature of zinc coated steel plates. Test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000 hours to evaluate the offsets of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and 5$0^{\circ}C$. From this result, spot welded specimens with 5 mm clearance have lower tensile-shear strength in the distilled water or synthetic sea water than without clearance. And they have lower tensile-shear strength under -4$0^{\circ}C$ and over 5$0^{\circ}C$.

A Study on a High-Temperature/High-Pressure Washing System in which High-Temperature Water is Generated in a Low-Pressure Boiler and High-Pressure Water is Generated Thereafter in a Compressor (저압보일러에서 고온의 온수 생성 후 압축기에서 고압수를 생성하는 고온·고압 세척시스템에 관한 연구)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.94-100
    • /
    • 2019
  • This study was conducted on a high-temperature/high-pressure washer in which low-pressure cold water in a boiler is heated to a temperature range of $70{\sim}80^{\circ}C$ by supplying diesel combustion heat. The high-temperature water is sent to a compressor to increase its pressure to 200 bar, thereby making high-temperature/high-pressure water, which is sprayed through a spray nozzle. In the results of this study, the spray temperature of the high-pressure washing was shown to be the highest when the ratio between the actual amount of combustible air and the theoretical amount of air was 1:1 and the energy consumption rate of the low-pressure boiler type high-pressure washer was shown to be much lower than that of the high-pressure boiler type high-pressure washer.

The Estimation of Marine Environmental Capacity for the Reception of Cooling Water from HTPP in Southern Waters of Cheju Island using a 3-D Hydrodynamic Model (화순화력발전소 주변해역의 온배수 환경용량 산정)

  • Kim Gwang-Su;Choi Young-Chan;Lee Moon-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.3-12
    • /
    • 2000
  • The field surveys and the measurements of seawater temperatures were conducted every month from 1997 to 1999, and the distributions of seawater temperature were simulated and reproduced by a three dimensional hydrodynamic numerical model over the southern waters of Cheju island. In order to estimate the marine environmental capacity for the reception of the heat loads of cooling water discharged from Hwasoon Thermal Power Plant(HTPP) in the study area, the simulations for predicting the situation of unfavorable environment in which marine organisms might not be satisfied with change in seawater temperature were peformed using a three dimensional hydrodynamic numerical model by controlling quantitatively the heat loads of cooling water from HTPP Currently, HTPP discharges cooling water of 35.9℃ into the sea as much as 112,800m³/day in summer. As the results of simulations, the more the heat loads from the power plant increase, the more increase the seawater temperatures around the water areas adjacent to the power plant. In case the heat loads of cooling water from HTPP become about 5 times as high as the present loads, seawater temperatures at near-shore waters adjacent to HTPP appear to be increased to the extent of 0.5℃ above the existing seawater temperature in summer. The marine environmental capacity for the reception of thermal discharge from HTPP is estimated to be about 530×10/sup 6/kcal/day which is equivalent to the increase of a factor of 2 in the temperature of cooling water without any change in the discharge rate of cooling water or which is equivalent to the increase of a factor of 4.6 in the discharge rate of cooling water without any change in the temperature of cooling water. Comparing the case of the increase in the discharge rate of cooling water with the case of the increase in the temperature of cooling water on the basis of the same heat loads of 530×10/sup 6/kal/day, the former case is expected to increase seawater temperature a little higher and to extend the area affected by heat loads a little broader.

  • PDF

Heat Transfer Experiment and Analysis to Predict the Efficiency of Heat Exchanger for Deep Geothermal System (심부지열 용 동축 열교환기 성능예측을 위한 열전달 실험 및 해석)

  • Jung, Kuk-Jin;Jeong, Yoon-Seong;Park, Jun Su;Lee, Dong Hyun
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • The Heat exchanger for deep geothermal system is very important to enhance the efficiency of the system. The co-axial heat exchanger is used due to the limitation of digging space. The heat transfer on the external surface of outer pipe should be high to receive a large amount of heat from the ground. However, the inner pipe should be insulated to reduce the heat loss and increase the temperature of discharge water. This study made experiment apparatus to describe the co-axial heat exchanger and measure the heat transfer coefficients on the internal and external surface. And the pin-fin was designed and fixed on the internal surface to increase the efficiency of heat exchanger. Finally, we calculated the temperature of discharge water using the heat transfer circuit of co-axial heat exchanger and heat transfer coefficient which from experimental results. The water temperature was reached the ground temperature at -500 m and following the ground temperature. When the water return to the ground surface, the water temperature was decreased due to heat loss. As the pin-fin case, the heat transfer coefficient on the internal surface was decreased by 30% and it mean that the pin-fin help to insulate the inner pipe. However, the discharge water temperature did not change although pin-fin fixed on the inner pipe.

Past and Future Temperature and Precipitation Changes over Korea using MM5 Model

  • Oh, Jai-Ho;Min, Young-Mi;Kim, Tae-Kook;Woo, Su-Min;Kwon, Won-Tae;Baek, Hee-Jeong
    • Proceedings of the Korean Quaternary Association Conference
    • /
    • 2004.06a
    • /
    • pp.29-29
    • /
    • 2004
  • Long term observational analysis by climatologists has confirmedthat the global warming is no longer a topic of debate among scientists andpolicy makers. According to the report of IPCC-2001 (Intergovernmental Panelon Climate Change), the global mean surface air temperature is increasinggradually. The reported increase of mean temperature is by 0.6 degree in the end of twentieth century. This could represent severe threat for propertylosses especially due to increase in the number of extreme weather arising out of global warming. period of model integration from 2001 to 2100 using output of ECHAM4/HOPE-G of Max Planet Institute of Meteorology (MPI) for IPCC SRES (Special Report on Emission Scenarios). The main results of this study indicate increase of surface air temperature by 6.20C and precipitation by 2.6% over Korea in the end of 21st century. Simulation results also show that there is increase in daily maximum and minimum temperatures while decrease in diurnal temperature range (DTR). DTR changes are diminished mainly due to relatively rapid increase of daily minimum temperature than that of daily maximumtemperature. It has been observed that increase in precipitation amount anddecrease in the number of rainy days lead to increase of pre precipitationintensity.

  • PDF