• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.044 seconds

Vibration control of a stay cable with a rotary electromagnetic inertial mass damper

  • Wang, Zhi Hao;Xu, Yan Wei;Gao, Hui;Chen, Zheng Qing;Xu, Kai;Zhao, Shun Bo
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.627-639
    • /
    • 2019
  • Passive control may not provide enough damping for a stay cable since the control devices are often restricted to a low location level. In order to enhance control performance of conventional passive dampers, a new type of damper integrated with a rotary electromagnetic damper providing variable damping force and a flywheel serving as an inertial mass, called the rotary electromagnetic inertial mass damper (REIMD), is presented for suppressing the cable vibrations in this paper. The mechanical model of the REIMD is theoretically derived according to generation mechanisms of the damping force and the inertial force, and further validated by performance tests. General dynamic characteristics of an idealized taut cable with a REIMD installed close to the cable end are theoretically investigated, and parametric analysis are then conducted to investigate the effects of inertial mass and damping coefficient on vibration control performance. Finally, vibration control tests on a scaled cable model with a REIMD are performed to further verify mitigation performance through the first two modal additional damping ratios of the cable. Both the theoretical and experimental results show that control performance of the cable with the REIMD are much better than those of conventional passive viscous dampers, which mainly attributes to the increment of the damper displacement due to the inertial mass induced negative stiffness effects of the REIMD. Moreover, it is concluded that both inertial mass and damping coefficient of an optimum REIMD will decrease with the increase of the mode order of the cable, and oversize inertial mass may lead to negative effect on the control performance.

DCS Model Calculation for Steam Temperature System

  • Hwang, Jae-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1201-1204
    • /
    • 2004
  • This paper suggests a DCS (Distributed Control System) model for steam temperature system of the thermal power plant. The model calculated within sectional range is linear. In order to calculate mathematical models, the system is partitioned into two or three sectors according to its thermal conditions, that is, saturated water/steam and superheating state. It is divided into three sections; water supply, steam generation and steam heating loop. The steam heating loop is called 'superheater' or steam temperature system. Water spray supply is the control input. A first order linear model is extracted. For linear approach, sectional linearization is achieved. Modeling methodology is a decomposition-synthetic technique. Superheater is composed of several tube-blocks. For this block, linear input-output model is to be calculated. Each tiny model has its transfer function. By expanding these block models to total system, synthetic DCS linear models are derived. Control instrument include/exclude models are also considered. The resultant models include thermal combustion conditions, and applicable to practical plant engineering field.

  • PDF

Flood Control Operation Model of Reservoir Using CSUDP (CSUDP를 이용한 홍수기 댐운영)

  • Lim, Kwang-Suop;Shim, Kyu-Cheoul;Hwang, Yeon-Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.918-922
    • /
    • 2006
  • The purpose of this study is development of operation model for flood control of multi-reservoir in river basin, which can provide the best decision of reservoir release in timely and appropriately manner using CSUDP. For verification and validation of the developed system, the Gum River Basin was selected, which has 82 rainfall gauging stations, 28 water level gauging and 2 multi-purpose reservoirs which can control flood. There was a successful simulation of the developed model and system, using the real-time data from the Han River Basin Flood Forecast Center. Specially, case study for '1995 flood was performed.

  • PDF

On-off Dewatering Control for Lipase-catalyzed Synthesis of n-Butyl Oleate in n-Hexane by Tubular Type Pervaporation System

  • Kwon, Seok-Joon;Rhee, Joon-Shick
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.2
    • /
    • pp.165-170
    • /
    • 1998
  • Lipase-catalyzed esterification of n-butyl oleate was carried out in n-hexane as a model reaction. The optimal activity of Candida rugosa lipase was shown in a water activity ($a_w$) range of 0.52 to 0.65 at $30^{\circ}C$. The water produced from the esterification was removed by a tubular type pervaporation system. The rate of ester formed from the enzymatic esterification was allowed to be the same as the rate of water removal by maintaining an optimal $a_w$ of the reaction system using an on-off dewatering control device. The reaction rate and yield with a$a_w$ control were increased two folds higher than the respective values for the uncontrolled reaction.

  • PDF

A Basic Study of Water Basin Experiment for Underwater Robot with Improving usability (사용자 운용 편의성을 위한 수중로봇 MR-1의 수조실험에 관한 연구)

  • Nam, Keonseok;Ryu, Jedoo;Ha, Kyoungnam
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.1
    • /
    • pp.32-38
    • /
    • 2020
  • This paper describes a method for tracking attitude and position of underwater robots. Underwater work with underwater robots is subject to differences in work efficiency depending on the skill of the operator and the utilization of additional sensors. Therefore, this study developed an underwater robot that can operate autonomously and maintain a certain attitude when working underwater to reduce difference of work efficiency. The developed underwater robot uses 8 thrusters to control 6 degrees of freedom motion, IMU (Inertial Measurement Unit), DVL (Doppler Velocity Log) and PS (Pressure Sensor) to measure attitude and position. In addition, the thruster allocation algorithm was designed to follow the control desired value using 8 thrusters, and the motion control experiments were performed in the engineering water basin using the thruster allocation method.

A Development of the Grain Moisture Dry System Using Water-rate Compensator and PID Controller (함수율 보정기와 PID제어기를 이용한 곡물 수분 건조 시스템 개발)

  • Lee, Chang-Kuen;Shim, Woo-Chul;Park, Sung-Jin;Hong, Yeon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.315-318
    • /
    • 2001
  • In this paper recommends the development of automated silo dry & storage system. Most of existing round shaped iron silo arc used for only storage after dry and have many problems in storing. So We have developed an automated dry system which used the previously equipped silo and enables it to be used for storage after dry. The system features high frequency-resistance water sensor in Hopper scale that is in general use within the country its silo that is manufactured by the nerve DSP(TMS320C32) system water compensator and visualization that is finally realized with a personal computer.

  • PDF

Development of Automation System of Water-Hydraulic and Leakage Test for Pressure Vessel (압력용기 수압 및 기밀시험 자동화 시스템 개발)

  • 이원희;김동수;이승현;김광영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1672-1675
    • /
    • 2003
  • In this study, we developed full automation test system for pressure vessel. This pressure vessel containing oxygen, nitrogen and carbon is widely used in industrial field. The test items of pressure vessel are divided into three branches which is weight measurement, water-hydraulic, and leakage test. After leakage test is completed, cleaning and dry progress is carried out. And control system is consist of three controller which is PLC, monitoring system and database system. PLC is control all of system. Monitoring system measures weight, pressure, flow etc and display to all conditions. Database system stores tested data. we design system to control all test modules in communication by a second period with three control modules. Finally, we verified this system by field test.

  • PDF

A Study on the Optimized Pump Selection of the Cooling System for the PEFP DTL Accelerator (PEFP DTL 냉각시스템의 펌프 선정 최적화에 관한 연구)

  • Park, Jun;Kim, Kyung-Ryul;Kim, Hyung-Gyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1277-1282
    • /
    • 2009
  • The main objective of this prototype is to control resonance frequency of DTL system through the temperature control of cooling water. It is to resonant frequency of the drift tube cavities to 350 MHz. This paper describes the design of a prototype cooling water skid required for the temperature control of the DTL cavities, focusing in the modeling and simulation of the cooling system, the sizing of water pumping skid component.

  • PDF

Effects of Dietary Supplementation of Chitosan on the Metabolism of Lead in Rats (랫드에 있어서 키토산이 납중독의 대사에 미치는 영향)

  • 권오덕;정규용
    • Toxicological Research
    • /
    • v.19 no.4
    • /
    • pp.315-320
    • /
    • 2003
  • This study was carried out to investigate the effect of chitosan on lead metabolism in SD rats. Ten male rats were divided into a experimental group and a control group. Each experimental and control rats were administered by water contaminated with 100 mg/l of lead for 4 weeks, respectively. Experimental group received diets supplemented artificially with 5% of chitosan for 4 weeks. Body weight change, food and water consumption, fecal and urinary excretion, and fecal and urinary lead excretion were measured. There were no significant differences in body weight gain, food and water consumption, and fecal and urinary excretion between the two groups. However, fecal lead excretion of rats fed the diet containing 5% of chitosan were higher than the control group. Whereas urinary lead excretion of rats fed the diet containing 5% of chitosan were lower than the control group. The results suggested that the oral administration of chitosan prevents the gastrointestinal lead absorption in rats.

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).