• Title/Summary/Keyword: volume measurement

Search Result 1,621, Processing Time 0.025 seconds

The Measurement of Soot Particle Temperatures Using a Ratio Pyrometry (Ratio Pyrometry를 이용한 매연입자 온도 계측에 대한 고찰)

  • Nam, Youn-Woo;Lee, Won-Nam;Lee, Chun-Beom
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.124-129
    • /
    • 2004
  • The ratio pyrometry has been investigated experimentally for the measurement of soot particle temperatures in a diffusion flame. A tungsten lamp calibration system was constructed and used in order to calibrate the ratio pyrometry and two-color pyrometry using a KL-factor method. Once the ratio pyrometry is properly calibrated, temperatures measured using a ratio pyrometry were virtually identical to those obtained from a KL-factor method. The effect of soot volume fraction on temperature measurement was almost negligible, and therefore, the ratio pyrometry could provide the useful temperature information of sooting flames. The potential application of a ratio pyrometry to a 2-D temperature measurement without sacrificing the accuracy was demonstrated.

  • PDF

Development of Fuel Economy Measurement Method for Hydrogen Fuel Cell Vehicles (수소연료전지자동차 연료소비율 측정방법에 대한 연구)

  • Lim, Jong-Soon;Choi, Young-Tae;Yong, Gee-Joong;Kwon, Hae-Boung;Lee, Hyun-Woo;Maeng, Jeong-Yoel
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.636-639
    • /
    • 2009
  • Fuel consumption measurement of Hydrogen fuel cell vehicle is considerably different form internal combustion engine vehicle such as carbon balance method. A practical method of fuel Consumption measurement has been developed for Hydrogen fuel cell vehicles. There are three method of hydrogen fuel consumption testing, gravimetric, PVT(Pressure, Volume and temperature), and Coriolis mass flow, all of which necessitate physical measurements of the fuel supply. The purpose of this research is to measure the fuel consumption of hydrogen fuel cell vehicles on chassis-dynamometer and to give information when the research is intended to develop method to measure hydrogen fuel consumption.

  • PDF

Cause Analysis of Level Measurement Error in Steam Generator of Nuclear Power Plant (원자력발전소의 증기발생기 수위계측 오차 원인분석)

  • Lee, Kwang-Dae;Oh, Eung-Se;Yang, Seung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.591-593
    • /
    • 2006
  • The differential pressure method has been used in the level measurement of steam generator in nuclear power plant. Two sensing lines from a steam generator to a pressure transmitter are needed to measure the high pressure and low pressure. The fluid conditions in the sensing line require the uniform phase with no bubbles and the slope of sensing line should be installed with forward slope. The expansion of the bubble volume according to the upper pressure and the reverse slope of sensing lines explain how the level errors took place.

  • PDF

Development of Portable Bio-signal Measurement System using Bluetooth for 24-hours Continuous Health Monitoring (24시간 건강상태 모니터링을 위한 Bluethooth를 사용한 소형 저전력 휴대형 Bio-signal 측정 장치를 개발)

  • 정현권;송길섭;나승유;이희영
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.81-84
    • /
    • 2001
  • This paper presents a potable bio-signal measurement system using Bluetooth for the 24-hours continuous health state monitoring of the elderly and the disabled. The measurement system has the functions of acquisition of various bio-signals, wireless data transmission and adjustment of parameters such as gain and cut-off frequency. This measurement system is designed according to the international specifications of the recommendation of AAMI (Association for the Advancement of Medical Instrumentation). The design targets of the developing system about volume and power consumption are 20x30x5mm$^3$ and 8mW.

  • PDF

Next Generation Fiber Length Measurement

  • Tiikkaja, Esa;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.54-59
    • /
    • 2000
  • The next generation fibre size analyser has been developed in Kajaani based on over 15 years experience in fibre measurement. This new FiberLab-analyser can measure fibre length both along the fibre centre line and as projected. The cross-sectional measurements of fibre are in principle similar to the earlier version FiberLab. Measured data are generally displayed in distributions. Some new calculations have been added, for example the fibres cross sectional area and fibre volume index both available as distributions as well. The performance of the FiberLab measurement is verified against the manual microscopic testing. These tests show that the new image analysis-based measurement well matches with the manual methods.

  • PDF

A Study on the Combustion Characteristics of Lean Mixture by Radicals Induced Injection in a Constant Volume Combustor (1) (정적연소기에서 라디칼 유도분사를 이용한 희박혼합기의 연소특성에 관한 연구 (1))

  • 박종상;이태원;하종률;정성식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.45-53
    • /
    • 2004
  • An experimental study was carried out to obtain the fundamental data about the effects of radicals induced injection on premixture combustion. A constant volume combustor divided to the sub-chamber and the main chamber was used. The volume of the sub-chamber is set up to occupy less than 1.5% of that of whole combustion chamber. Radial twelve narrow passage holes are arranged between the main chamber and the sub-chamber. The products including radicals generated by spark ignition in the sub-chamber will derive the simultaneous multi-point ignition in the main chamber. While the equivalence ratio of pre-mixture in the main chamber and the sub-chamber is uniform. We have examined the effects of the sub-chamber volume, the diameter of passage hole, and the equivalence ratio on the combustion characteristics by means of burning pressure measurement and flame visualization. In the case of radical ignition method(RI), the overall turning time including the ignition delay became very short and the maximum burning pressure was slightly increased in comparison with those of the conventional spark ignition method(SI), that is, single chamber combustion without the sub-chamber. The combustible lean limit by RI method is extended to more ER=0.25 than that by SI method. Therefore the decrease of every emission including NOx and the improvement of fuel consumption is anticipated due to lean burn.

Development and Evaluation of High-precision Earth-work Calculating System using Drone Survey (드론을 활용한 고정밀 토공량 산출 시스템 개발 및 평가)

  • Kim, Sewon;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.87-95
    • /
    • 2019
  • Earth-work calculation is the important data for estimating the optimal construction cost at the construction site. Earth-work calculations require the accurate terrain data and precise soil volume calculations. Drone surveying technology provides accurate topography in a short time and economic advantages. In this paper, a drone surveying technique was used to derive a high precision soil volume calculation system. Field demonstration were performed to verify the accuracy of the volume measurement system. The results of earth-work calculation using drone survey were compared with those of GPS surveying. In addition, the developed earth-work volume calculation algorithm is compared with the existing aerial survey software (Pix4D) to verify the accuracy.

Volume Resistivity Characteristics of Epoxy Resin using Nanocomposites (나노 컴퍼지트 에폭시 절연재료의 체적 고유저항 특성)

  • Choi, Hyun-Min;Kim, Joung-Sik;Kim, Won-Jong;Park, Young-Ha;Kim, Gwi-Yeol;Shin, Jong-Yeol;Lee, Jong-Yong;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.387-387
    • /
    • 2009
  • In the study the volume resistivity Characteristics of epoxy resin using nanocomposites, nano-comosites are made from insulating material epoxy resin using for power transformer equipment and molding several devices as changing amount of addition of diameter 12 [nm] $SiO_2$, we measured volume resistivity of nano-composites by High Resistance Meter(4329A). As the result of measurement, we have seen the epoxy resin using 1.6 [wt%] nanocomposites was the highest measured at the volume resistivity, and using 0.4 [wt%] nanocomposites was highest stabilized than others according to variable temperature properties.

  • PDF

A Study on the Waste Volume Calculation for Efficient Volume Monitoring in a Landfill Facility (매립장의 효율적인 체적 모니터링을 위한 체적 계산 방법에 대한 연구)

  • Lee, Young Dae;Cho, Sung Youn
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.153-159
    • /
    • 2012
  • For the enhancement of civilization of a city, the standard landfill facility is needed for the efficient, and computerized management. In this paper, we proposed the waste volume calculation method using the point cloud of the surface of three dimensional object based on stereo camera measurement. This computes the quantity of waste volume for continuos monitoring. It helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, it can be used for the basis of general algorithm of three dimensional object.

Measurement Method of the Masseter Muscle Volume Using 3D Computed Tomography (3D CT를 이용한 교근의 부피측정)

  • Baek, Jung Hwan;Choi, Jong Woo;Yoo, Sun Kuk;Kim, Yong Oock;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.589-592
    • /
    • 2005
  • Since G.N. Hounsfield's clinical use of computed tomography in 1971, digital imaging technique using computers has shown an eye opening progress. Progress has made 3-dimensional understanding of not only facial bones but muscles and other connective tissues possible through 3-dimensional reconstruction of preexisting tomographical images. Also, quantitative analysis of density, distance, volume has become possible, allowing objective analysis of preoperative and postoperative states through imaging. The authors measured the masseter muscle volume of 20 normal individuals and 8 female patients through 3-D reconstructive CT imaging and made a statistical analysis of the measurements. The method used in our study may be applied to the diagnosis of disease causing the change of the facial volume and presurgical design as a useful tool to provide objective information on the evaluation of surgery outcome.