• 제목/요약/키워드: voltage capacity

검색결과 978건 처리시간 0.028초

전기자동차용 충전기의 가변출력 및 병렬운전 제어 (Variable Output and Parallel Operation Control of EV Charger)

  • 이상혁;강성구;아와스티 프라카시;황정구;이승열;위한별;박성준
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.153-160
    • /
    • 2013
  • This research paper describes the development of battery charger with a variable output voltage capacity for charging the batteries used in electrical vehicles. The voltage and current accordingly is control via the buck converter that receives three phase current at primary side and fed to bridge rectifier which is comprised of full bridge converter and HFTR(High Frequency Transformer) for isolation and a square wave AC output. The transformer primary side is in series to divide certain charging current and the secondary side is comprised of six fix transformers so that they can generate certain amount of power and various output voltage through relay connection using 6 DC outputs. Moreover, all parallel connected full bridge serial resonant converter communicate together with upper(main) controller. The constructed structure is verified by conducting the test on PSIM as well as experimentally.

DC전철구간의 에너지회생장치 개발 방향 (Direction for Development of Energy Regeneration Device for DC Electric Railway System)

  • 김용기;배창한;한문섭;양영철;장수진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

초초고압용 OF 케이블 접속함의 국산화를 위한 연구 (A Study on the Ultra-high Voltage Oil Filed Cable Joint)

  • 이수길;전승익;박완기;김화종;박양호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1825-1827
    • /
    • 1996
  • In this study, the Joint of 345kV OF $1C{\times}2000mm^2$ cable was developed to keep up with the trends that need higher-voltage & capacity underground transmission line. The type of joint developed was based on the two kinds of models that have had a good reliability internationally. The mechnic and electric characteristics of the sample specimen was managed in detail when it was manufactured and estimated. Especially, in order to prove the reliability of usage for 30 years, the method of long term aging test was studied. As a result of test, we knew that the joint developed had a good performance. From this study, it can be thought that future ultra-high voltage underground transmission line could be constructed by domestic technology.

  • PDF

고전압 Field Stop IGBT의 최적화 설계에 관한 연구 (The Optimal Design of High Voltage Field Stop IGBT)

  • 안병섭;장란향;류용;강이구
    • 한국전기전자재료학회논문지
    • /
    • 제28권8호
    • /
    • pp.486-489
    • /
    • 2015
  • Power semiconductor device has a very long history among semiconductor, since the invention of low-pressure bipolar transistor 1947, and so far from small capacity to withstand voltage-current, high-speed and high-frequency characteristics have been developed with high function. In this study, the PWM IC Switch to the main parts used in IGBT (insulated gate bipolar transistor) for the low power loss and high drive capability of the simulator to Synopsys' T-CAD used by the 1,700 V NPT Planar IGBT, 1,700 V FS was a study of the Planar IGBT, the results confirmed that IGBT 1,700 V FS Planar is making about 11 percent less than the first designed NPT Planar IGBT.

인터리브드 소프트 스위칭 부스트 컨버터의 입출력 리플 분석 (Input/Output Ripple Analysis of Interleaved Soft Switching Boost Converter)

  • 정두용;지용혁;김영렬;정용채;원충연
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.182-189
    • /
    • 2012
  • In this paper, the input current and output voltage ripple of the soft switching interleaved boost converter was analyzed. Ripples of input current and output voltage with an interleaved method is analysed and as a result, the facts that it has lower ripple current than conventional interleaved method is verified. it means that a capacity of a main inductor can be reduced. Besides, a low capacitance of capacitor which means high lifetime and confidence can be used because of reducing ripples of output voltage. In order to verify the validity of the proposed converter used 10uF film capacitor, experiment was performed, and the efficiency of the proposed converter was measured with variable load and duty conditions.

Applications of Low-voltage Ohmic Process Combined with Temperature Control System to Enhance Salting Process of Pork

  • Hong, Geun-Pyo;Chun, Ji-Yeon;Choi, Mi-Jung
    • 한국축산식품학회지
    • /
    • 제32권3호
    • /
    • pp.293-300
    • /
    • 2012
  • This study investigated the effects of a low-voltage ohmic heating process (2.5 and 3.8 V/cm) on the thawing characteristics and NaCl diffusion of pork. The thawing rate of pork was dependent on the applied voltages and brine salinities, and few differences were obtained in pork quality parameters (color, water-holding capacity, and shear force) regarding the different treatments. The NaCl concentration of pork after ohmic thawing was higher than that following brine-immersion thawing, however, the NaCl diffusion did not differ from when fresh meat was immersed in brine. For application of the ohmic process in fresh pork, various ohmic pulses were generated in order to prevent the meat from overheating, and the results indicated that the ohmic process was a better way to enhance NaCl diffusion compared with immersing pork at high temperature. Although the mechanisms involved in NaCl diffusion at low-voltage electric field strength were unclear, the present study demonstrated that the ohmic process has a potential benefit in the application of meat processing.

고압한류퓨즈의 최적 차단을 위한 설계변수의 영향 (The Effects of Design Parameter to Interrupt Optimally for High Voltage CL Fuse)

  • 이세현;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.185-191
    • /
    • 1999
  • The fuse used in the high voltage distribution line often fails due to the active ionization caused by the strong electric field at fuse terminal. To suppress the ionization at the high voltage and high capacity current limiting fuse, the particle size and compactness of silica sand, the design, length, notch number and material of element, the diameter and length of fuse body must be considered carefully. However, these are not many proper which is treated with the inherent interrupting characteristics from many parameters at present. Because of these reasons, time and effort are needed to develop the new type fuse by the fuse designers in relation with the inherent characteristics from each of parameters. In this paper we choose 7 parameters with weight value based on study and experimentation and analyzed the characteristics of arcing period. In addition, we proposed the experimental method to experimentation and analyzed the characteristics of arcing period. In addition, we proposed the experimental method to extract the optimal design parameters with minimal effort as related the mutual effect from each of the parameters.

  • PDF

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안 (Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems)

  • 이유정;김규호;이상근;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

직류안정전화원의 제어소자에 전력소모의 최소화에 관한 연구 (A Study on the Minimization of Power Dissipation in Control Element of the Series D.C. Voltage Regulator)

  • 최병하;이균하;최희태
    • 대한전자공학회논문지
    • /
    • 제12권5호
    • /
    • pp.12-18
    • /
    • 1975
  • Triac phase controlled pre-regulator를 이용한 직류안정화전원에서 제어소자 전력소모를 촤소로 줄이기 위하여, 부하전류의 증가에 따라 제어소자 양단전압을 낮추어 주는 회로를 고안하여 부가하였다. 이렇게 하므로써 제어소자의 전력소모가 약 40%정도 감소되어 방열장치가 간단해지거나 전력용량을 증가할 수 있게 되었으며 열발산이 곤란한 monolithic I.C.화에 유용하도록 하였다. A method on minimizing the power dissipation in the control element of a series D.C. voltage regutator is devised. An additional control circuit which reduces the average voltage drop across the control element according to increasing the load current is attached :o the trial phase controlled pre-regulator system. It is verified that the power dissipation in the control element is reduced up to 40% by this. circuit arrangement. The heat sink system can be simplified and the capacity of tile handling power is also increased. It is expected that this circuit arrangement can be applied to I.C. fabrication.

  • PDF