• 제목/요약/키워드: ventilation equipment

검색결과 202건 처리시간 0.03초

원자력발전소 주제어실 공기조화계통 기능적설비그룹 개발 (FEG Development of MCR HVAC System for NPP)

  • 현진우
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.21-25
    • /
    • 2012
  • Functional Equipment Group(FEG) of Nuclear Power Plant(NPP) is the bundling of multiple equipment subcomponents around a major equipment with a common system isolation characteristic or out-of-service consideration. The main purpose of FEG is to reduce out-of-service time to enhance maintenance effectiveness. KHNP(Korea hydro & Nuclear Power Co.) needs to develop these FEGs to successfully perform On-line Maintenance(OLM) which will be expected to institute in the future. Recently, there has been growing interest in OLM in KHNP. The aim of this paper is to suggest the way of FEG development and to build the FEG of MCR(Main Control Room) HVAC(Heat, Ventilation and Air Conditioning) system. The results of this study might be make good use of OLM and be helpful for equipment maintenance for MCR HVAC system.

대단면 석회석 광산 갱도 내 국부선풍기 승압력 및 통기효과 비교 연구 (A Comparative Study on the Auxiliary Fan Pressure and the Ventilation Efficiency in Large-opening Limestone Mine Airways)

  • 박동준;강현호;이창우
    • 터널과지하공간
    • /
    • 제27권1호
    • /
    • pp.1-11
    • /
    • 2017
  • 국내 지하 석회석 광산은 대부분 대단면 갱도로 개발되고 있으며 갱내통기는 주요 선풍기에 의한 통기방식보다는 자연통기 및 국부통기에 의존하고 있다. 국부통기는 국부선풍기와 풍관을 이용한 급배기 통기방식을 적용하고 있으나 대단면 갱도 특성과 갱내 굴진 운반장비의 디젤화에 따라 소요통기량이 대폭 증대하여 통기의 효율 및 경제성 확보가 주요과제로 대두되고 있다. 본 연구에서는 대단면 갱내 작업장 국부통기를 위한 선풍기 용량 최적화를 위하여 축류식 및 프로펠러 선풍기를 개발하여 갱내 승압력 및 통기효과를 비교 분석함을 목적으로 한다.

백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과 (Assistant device development and effects for promotion of bag-valve-mask ventilation)

  • 권찬양;이인수
    • 한국응급구조학회지
    • /
    • 제22권1호
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.

화물유 펌프실의 환기특성에 관한 연구 (A Study on Ventilation Characteristics of Cargo-oil pump room)

  • 박찬수;조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.134-141
    • /
    • 2000
  • In this study, a scaled model chamber was built to investigate ventilation characteristics of the Under floor Air-conditioning System. Experimental study was performed in model for cargo-oil pump room with inlet and outlet by visualization equipment with laser apparatus. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000) which adopted two-frame grey-level cross correlation algorithm. The flow pattern reveals the large scale counterclockwise forced-vortex rotation from upside louver to lower scupper toward diagonal corner and also found small eddies at bottom layer

  • PDF

수술실내 공기감염억제를 위한 공조용 급배기구 위치 선정에 관한 연구 (A Study on the Diffuser Location for the Reduction of Airborne Infection in Operation Room)

  • 권순정;주영철;김천숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권1호
    • /
    • pp.7-12
    • /
    • 2002
  • The air ventilation system of operation rooms has been studied to prevent the cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals were investigated. The distribution of microbe was measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room was developed for the CFD(Computational Fluid Dynamics) analysis. The characteristics of air flow in the empty operation room and in occupied operation room were calculated by using a CFD program. The current diffuser location of an old hospital did not deliver the clean air to the operation part efficiently. A new method to locate diffusers that improve air venting with little increase of the cost of equipment was suggested.

  • PDF

벤트 그릴 조립공정 자동화를 위한 자동화지그 개발 (The Development of an Automation Jig for the Vent Grille Assembly Process)

  • 김진우;박범석;한창수
    • 한국공작기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.87-92
    • /
    • 2005
  • In this study, an automation assembly jig for the automation assembly process for the ventilation grille that is used in the interior of a car Is developed. As the method that can do the automation assembly for the ventilation grille, a simple jig and air cylinder have been applied. And a solenoid valve, a filter regulator, and on-off switch have been used in controlling the system. Moreover, the timer is attached to the equipment so that a worker may control the assembly time, as fitting the quantity on demand of production. Actually with executing the assembly test productivity and performance of assembly have been verified. In case of the automation assembly work for a ventilation grille is compared to the manual work. The optimum working speed has been identified to make the process twice or three times better.

벤트 그릴 조립공정 자동화를 위한 자동화 지그 개발 (The Development of an Automation Jig for the Vent Grille Assembly Process)

  • 김진우;한창수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.77-82
    • /
    • 2000
  • In this study, an automation assembly jig for the automation assembly process for the ventilation grille that is used in the interior of a car is developed. As the method that can do the automation assembly for the ventilation grille, a simple jig and air cylinder have been applied. And a solenoid valve, a filter regulator, and on-off switch have been used in controlling the system. Moreover, the timer is attached to the equipment so that a worker may control the assembly time, as fitting the quantity on demand of production. Actually with executing the assembly test productivity and performance of assembly have been verified. In case of the automation assembly work for a ventilation grille is compared to the manual work. The optimum working speed has been identified to make the process twice or three times better.

  • PDF

선박의 기관실 통풍 해석 (Ventilation Analysis for an Engine Room of a Ship)

  • 이혁;서형균
    • 대한조선학회논문집
    • /
    • 제41권5호
    • /
    • pp.63-69
    • /
    • 2004
  • This study contains the CFD analysis to predict the flow in engine room and utilize the results as a reference for arranging smoke detectors. FLUENT, a commercial CFD code is adopted because of its good application experience in DSME(Daewoo Shipbuilding & Marine Engineering Co.. Ltd.). The target is the engine room of VLCC. which was delivered in 2002. The model for analysis includes main structure elements, ventilation ducts, main engine and other big size equipment. From the analysis results, the internal flow pattern can be observed and some guidelines for the position of smoke detectors cane be presented.

Natural Ventilation in High-Rise Building with Double Facades, saving or waste of Energy

  • Lee, Eung-Jik;Pasquay, Till
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.39-45
    • /
    • 2002
  • Double facades are built to allow natural ventilation in high rise buildings and buildings with high outside noise level. In high rise Buildings the gains in summer can be reduced by sufficient sun protection devices placed outside the rooms in the ventilated space between the inner and outer facade. To evaluate the energetic performance, three buildings with double facade were monitored for at least one year (Siemens Building in Dortmund/Germany, Victoria Insurance Company in Duesseldorf/Germany and RWE Tower in Essen/Germany). The results document the indoor climate, the boundary conditions for further planning and the possibilities for high rise buildings without or with little cooling facilities.

U-CDS의 자연환기를 위한 AirDam시스템의 효과에 대한 연구 (System Effectiveness of AirDam for Natural Ventilation by U-CDS)

  • 김승철;신부현;오기대
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.87-92
    • /
    • 2022
  • Recently, there has been an increasing demand for electric equipment installed on the ground to be installed in an underground space. Accordingly, U-CDS (Underground-Compact Distribution Station) installed in the underground is supplied, and to improve its weak ventilation performance, an Airdam-type structure was applied and the effect was analyzed. As a result, the temperature around the transformer was reduced by up to 9.5 degrees, and the air flow increased by up to 1.17 m/s. Airdam structure can be supplied in the form of various sculptures because it is possible to design freely while maintaining its principle.