• 제목/요약/키워드: ventilation and air circulation

검색결과 43건 처리시간 0.022초

취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구 (A research on the $CO_2$ Peak Point Control according to Ventilation Frequency during Sleeping)

  • 원유미;김대승;이우진;김동규;김세환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.731-736
    • /
    • 2008
  • There was in a building and with the technical advance for a energy saving the secret efficiency of the building improved together and continuously was come. The indoor air environment brought about the deterioration which is remarkable because of it. But time of most the indoor air environmental matter is one in the element which healthily affects biggest in the moderns who lives from the interior space. Today the plan for the air environmental maintenance which dwelling space is appropriate is demanded, is the actual condition where the method of the ventilation control which is energy saving and efficient is necessary. From the research which it sees, number of ventilation 0.7 time of the aeration which is a domestic legal baseline is excessive is judged from the research which sees, The sleep hour assumes it stays most long the hour when, number of ventilation 0 time 0.1 times 0.4 times $CO_2$ consistency measurements and analyzes number of ventilation conclusive escape. And $CO_2$ peak point control leads it decides a data, effective and it talks an energy saving circulation control method and it does to sleep.

  • PDF

차내 환기구 형상변화에 대한 연구 (A Study ono the Type-Change of Automotive Register)

  • 김종원;윤종갑;배한;원성필
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.123-134
    • /
    • 1999
  • Nowadays since the automobile is regarded as the third living space, comfortable conditions are required in the passenger compartment. The customer's concern on air-conditioning/heating, ventilation and demisting/defrosting performances has been much increased. Both ventilation and demisting /defrosting performances are directly influenced by register location, shape of regist guide vane, ventilation flow rate, air distribution , and air circulation pattern. Diffuse plume of air from the register is desirable not only to maintain comfort when the comfort when the comfortable condition has been satisfied but to improve demisting /defrosting performance. In this study, experimental and numerical investigation about the flow field of six different register vane types were carried out , respectively. The numerical analysis, based upon the $textsc{k}$-$\varepsilon$ turbulence model , was applied to the air flow field. The results show that the shape of register guide vane should be considered as an important design paramter.

  • PDF

한반도 대기정체의 특성 및 지역기후모델 HadGEM3-RA를 이용한 미래 전망 (Characteristics of Air Stagnation over the Korean Peninsula and Projection Using Regional Climate Model of HadGEM3-RA)

  • 김도현;김진욱;김태준;변재영;김진원;권상훈;김연희
    • 대기
    • /
    • 제30권4호
    • /
    • pp.377-390
    • /
    • 2020
  • Not only emissions, but also atmospheric circulation is a key factor that affects local particulate matters (PM) concentrations in Korea through ventilation effects and transboundary transports. As part of the atmospheric circulation, air stagnation especially adversely affects local air quality due to weak ventilation. This study investigates the large-scale circulation related to air stagnation over Korea during winter and projects the climate change impacts on atmospheric patterns, using observed PM data, reanalysis and regional climate projections from HadGEM3-RA with Modified Korea Particulate matter Index. Results show that the stagnation affects the PM concentration, accompanied by pressure ridge at upper troposphere and weaken zonal pressure gradient at lower troposphere. Downscaling using HadGEM3-RA is found to yield Added-Value in the simulated low tropospheric winds. For projection of future stagnation, SSP5-8.5 and SSP1-2.6 (high and low emission) scenarios are used here. It has been found that the stagnation condition occurs more frequently by 11% under SSP5-8.5 and by 5% under SSP1-2.6 than in present-day climate and is most affected by changes in surface wind speed. The increase in the stagnation conditions is related to anticyclonic circulation anomaly at upper troposphere and weaken meridional pressure gradient at lower troposphere. Considering that the present East Asian winter monsoon is mainly affected by change in zonal pressure gradient, it is worth paying attention to this change in the meridional gradient. Our results suggest that future warming condition increase the frequency of air stagnation over Korea during winter with response of atmospheric circulation and its nonlinearity.

지하철 자연환기구 공기 이동량 조사 (Investigation of amount of the Air Flow through a Natural Ventilator in the Subway System)

  • 배성준;황선호;신창헌;김신도;이경빈;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1480-1486
    • /
    • 2011
  • 지하철 승강장의 스크린도어가 설치되기 전에는 승강장을 통해 환기되던 공기가 스크린 도어가 설치된 후에는 터널 내부에 정체되면서 미세먼지에 의한 환경이 더 악화되고 있는 실정이며, 터널환기구가 터널에 정체된 공기의 유일한 순환구로 이용되고 있다. 스크린 도어는 기존 터널환기시스템을 설계할 때 고려되었던 사안은 아니었으며, 지하철 운행 시 스크린도어 설치로 인한 지하 터널 속에서의 공기역학적 변화는 매우 클 것이다. 그러나 지하철이 통과하는 공간인 터널환기에 대한 연구는 미미한 수준이다. 이에 열차가 지하 터널 구간을 운행할 때 발생하는 열차풍에 의한 기류속도를 측정하고, 전철구간의 자연 환기구를 통한 기류의 유입 및 유출 특성을 정량적으로 평가하여 대표적인 기류패턴을 추출함으로써 향후 지하 터널 신설 및 환기 설비 설계에 따른 기초 자료를 제공하고자 한다.

  • PDF

다연동 온실의 자연환기효율성 비교 분석 (Comparative Study on Efficiencies of Naturally-Ventilated Multi-Span Greenhouses in Korea)

  • 권순홍;정성원;권순구;박종민;최원식;김종순
    • 한국산업융합학회 논문집
    • /
    • 제20권1호
    • /
    • pp.8-18
    • /
    • 2017
  • This research analyzed the ventilation effect of the multi-span greenhouse based on the types of greenhouse structure, weather conditions, and locations inside the greenhouse. To compare and analyze the ventilation effects with different types of greenhouse, the uniform environmental conditions should be selected in advance. But these factors are not controlled and require tense many precision facilities and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantitatively. In addition, for the ventilation effect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the current ventilation measurement method. The calculation error of ventilation rate using TGD was low (10.5%). Thus, the TGD is very effective in calculating the ventilation efficiency. The wind direction of 90 degrees showed the best ventilation effect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tool for simulating flow behavior in greenhouse.

주거 공간 내 건축 구성 요소의 안전성 분석 (An Analysis on the Safety related to Architectural Elements in Housing)

  • 이훈;이용희;정상규
    • KIEAE Journal
    • /
    • 제5권4호
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this study is to analyze the safety issues with regard to architectural elements in housing. Causes of accidents and threats to health are reviewed for 'safety' aspects. Threats to health tend to draw more attention due to recent increase of SHS and its public perceptions. The majority of victims by accidents in residential houses are on juveniles aged under 14 in bathrooms and living rooms. Non-slip finish materials are recommended to floors for access and circulation and protective pads to furniture edges. Colored glass may increase the safety of the windows in the living room. Handles and non-slip mats will be a good addition for the safety. Human scale design of the kitchen system is mandatory and appropriate size of storages for hazardous equipment are to be provided. Passive air ventilation for better air quality by dwellers in residence is occasionally used whereas large-scale apartments provide mechanical ventilation to supplement the volume of fresh air. Since the internal air quality is proved one of the major causes of atopic and respiratory diseases, steady effort to achive better air quality utilizing appropriate materials, plants and equipment is mandatory. Frequent cleaning and the use of anti-fungus materials are necessary because House Dust Mites are believed to be one of main causes of such diseases.

강제환기장치 사용에 따른 단동 플라스틱 온실 기온 강하 특성 (Characteristics of Cooling Effect Depending on Operation of Forced Ventilation Systems in a Single-span Plastic Greenhouse)

  • 김성헌;김형권;권진경;이시영
    • 생물환경조절학회지
    • /
    • 제31권3호
    • /
    • pp.143-151
    • /
    • 2022
  • 본 연구는 권취식 측창을 갖는 아치형 단동 플라스틱 온실 내 강제환기장치 설치 및 운용, 환기 성능 개선방안 등을 제안하기 위해 온실 내부에 유동팬과 배기팬을 설치하여 강제환기장치 사용에 따른 온실 내부기온 강하 특성을 정량적으로 조사하였다. 시험은 3가지 환기 조건(측창, 측창+순환팬, 측창+순환팬+배기팬)에서 수행되었다. 각 조건 데이터로거를 이용하여 환기 시작과 동시에 온실 내외부 기온 및 외부환경 변화를 측정·기록하였고, 환기 방식별 기온차 변화의 평균값으로 부터 정규기온차를 계산하여 기온 강하 효과를 비교하였다. 오전(11:00-12:00)에는 환기 방식에 상관없이 환기 초반 정규기온차가 일시적으로 증가했다가 감소하는 것으로 나타났다. 강제환기장치가 더 많이 사용될수록 최대 정규기온차는 1.158에서 1.037로 감소하였고 최대 정규기온차에 도달하는 시간도 340초에서 110초로 단축되었다. 강제환기장치의 사용은 정규기온차가 0.8까지 감소하는데 소요된 시간을 1,030초에서 550초로, 0.6까지는 1,610초에서 915초로, 0.4까지는 2,315초에서 1,360초로, 자연환기의 약60% 수준으로 감소시켰다. 오후(14:00-15:00)에는 정규기온차의 증가가 관측되지 않았지만, 환기 시작과 동시에 기온차가 감소하기 시작했다. 또한 강제환기장치가 더 많이 사용될수록 정규기온차가 0.8까지 내려가는 시간을 560초에서 345초로, 0.6까지는 825초에서 540초로, 0.4까지는 560초에서 345초로, 약70% 수준으로 감소시켰다. 따라서, 보다 효과적이고 경제적인 환기를 위해 강제환기장치는 오전과 같이 열부하가 높은 환경에서 적극적으로 사용하는 것이 바람직하다고 판단된다.

토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석 (Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.215-224
    • /
    • 2009
  • 공기유동 제어기술의 개발을 위한 기초자료를 제공 할 목적으로 토마토 재배 온실의 냉난방과 환기 및 공기유동 관련 실태를 조사하고, 온실유형과 난방방식별 온습도 분포를 실측하여 균일도를 분석하였다. 충남 부여 세도지역의 토마토 재배 온실 136농가를 대상으로 조사한 결과 대부분을 차지하는 단동 플라스틱 온실의 천창 설치 비율이 낮고 환기팬과 유동팬 설치비율도 매우 낮을 뿐만 아니라 설치제원도 편차가 매우 큰 것으로 나타났다. 아치형 단동 플라스틱온실의 천창 환기 구조의 개발보급과 연동곡부의 천창도 지붕상부로 이동시킬 필요가 있으며, 개별 천창구조 및 환기팬과 유동팬에 대한 설치 가이드라인의 제정이 요구된다. 냉방설비를 설치한 농가는 하나도 없었으며 난방방식의 대부분을 차지하는 온풍난방에서 덕트의 설치제원 역시 편차가 큰 것으로 나타났고, 온풍덕트의 배기풍속 및 배기온도 또한 거리에 따른 편차가 매우 큰 것으로 관측되었다. 수출경쟁력 화보를 위한 고품질의 생산물을 연중 안정적으로 생산하기 위해서는 온실냉방기술의 보급이 절실하며 난방방식이나 덕트설치 방식의 개선이 필요한 것으로 판단된다. 온실내 온습도 분포가 균일한지 여부를 판단하는 지표로 사용되고 있는 최대 편차와 실제 균등한 정도를 나타낼 수 있는 균일도와의 관계를 분석해 본 결과 높은 상관관계를 보였으나 주간에는 직선식으로 야간에는 2차 곡선식으로 다르게 표현되었다. 온습도 분포의 균일한 정도를 판정할 수 있는 객관적인 기준이 마련된다면 최대편차 대신 균일도를 지표로 사용하는 것이 더 합리적일 것으로 판단된다. 온실유형과 난방방식에 따라 온 습도분포의 균일도가 상당히 다른 것을 확인할 수 있었으며 야간에는 온수난방의 경우 이랑배관으로, 온풍난방의 경우 온풍덕트의 적절한 배치를 통하여, 주간에는 환기와 공기유동을 통하여 균일도를 개선할 수 있을 것으로 판단되었다.

크랭크실 환기장치의 오일 분리효율에 관한 연구 (A Study on Oil Separation Performance of Crank-Case Ventilation System)

  • 서준호;나병철;김진용;박승욱;임대순
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.144-150
    • /
    • 2008
  • This research aims to develop parts for advanced fuel/oil filtering re-circulation applicable to this kind of regulation proof engines. These parts can playa role of converting traditional air emission type crankcase into recovery type crankcase so that the engine can deal with environmental regulations, which do not allow minimal amount of toxic gas discharge. For the experiment, test method and specially made testing equipment are prepared. The results showed that oil separation efficiency of the cone type CCV(Crank Case Ventilation) system was higher than one of cylinder type both in bench test and in engine.

센서 및 MCU기반 지능형 환기창 빅데이터전송용 시스템 안정화에 관한 연구 (A Study on the Stabilization of a System for Big Data Transmission of Intelligent Ventilation Window based on Sensor and MCU)

  • 유희수
    • 한국전자통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.551-558
    • /
    • 2021
  • IoT와 센서를 기반으로 원격으로 제어할 수 있는 액추에이터 모듈의 지능형 환기 기능을 구현하기 위해, 실내 가스/CO2/습도 온도 및 실내/외 미세먼지 관련 실외 환경을 감지하는 사전 설정된 개수의 데이터를 기반으로 환기 포트를 개폐하기 위한 알고리즘 설계 및 구동 회로를 구성하여 환기창시스템을 구현하였다. 실내공기 순환모듈의 전송데이터관련 센서와 조건이 많아 데이터 저장·관리·분석에 어려움을 겪고 있다. 빅데이터 기술은 실내 공기 순환 시스템에 채택되어야 한다. 원격 모니터링과 원격 무선 제어 화면은 환기구시스템의 상태를 추출하여 관리함으로써 분리 및 작동 조건을 자동화할 수 있도록 구축되었다. 엑츄에이터 및 센서로 구성된 환기창시스템의 제어 및 센싱용 대량의 데이터전송 안정성을 확보하기 위해 MQTT를 적용하고 시스템 오류를 대비하여 운용의 빅데이터 안정적인 전송 보장을 위해 RocketMQ를 활용하여 시스템을 구성하였다.