• Title/Summary/Keyword: variable supply voltage

Search Result 132, Processing Time 0.021 seconds

AC Plasma Power Supply with Variable Voltage and Variable Frequency (가변전압 가변주파수(VVVF) 교류 플라즈마 전원장치)

  • Shin Wan-Ho;Yun Kee-Pok;Jeoung Hwan-Myoung;Choi Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1205-1207
    • /
    • 2004
  • AC plasma power supply is used to control a ozone generator and a air pollution gas. AC plasma power supply is composed of power semiconductor switch devices and control board adapted SHE(Selected Harmonic Elimination) PWM method. AC plasma power supply with sinusoidal VVVF(variable voltage and variable frequency) is realized. Its output voltage range is from 0 [V] to 20[kV] and output frequency range is from 8[kHz] to 20[kHz]. Using proposed system, AC high voltage and high frequency discharge is tested in the DBD(dieletric barrier discharge) reactor, and the space distribution of a its non-thermal plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

Maximum Efficiency Operation of SRM Drive System (스위치드 리럭턴스 전동기 구동시스템의 최대효율 운전)

  • Nam, J.H.;Shin, K.J.;Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2098-2100
    • /
    • 1997
  • The present paper investigates the optimal operation of a switched reluctance motor such that overall drive efficiency is maximized under a variable supply voltage. The operation under a variable supply voltage exhibits the improved drive efficiency in the full range of operating torque and speed, and exhibits the expanded range of operating torque and speed. Furthermore a variable supply voltage may be utilized in reducing torque ripple.

  • PDF

A study on ZVS-PWM Converter with Variable Output (가변 출력 영전압 스위칭 PWM 컨버터에 관한 연구)

  • Kim, Young-Jae;Im, Sang-Un;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.364-368
    • /
    • 1999
  • This paper suggests switching regulator technique to overcome the drawback of conventional variable linear power supply. Switching regulator technique can eliminate the extremely lossy operation and reduce the size and weight of variable linear power supply and provide nearly constant output power over the majority of output voltage range. The topology of variable switched mode power supply is employed active clamp forward converter with a current doubler rectifier and by using control of variable-frequency together with control of fixed-frequency, output voltage can be controled. Equivalent circuits pertinent to each operational mode of converter are derived, and an experimental 20V, 50A converter was designed and built. The converter operates from an output voltage of zero to 25 V, under 100 kHz switching frequency.

  • PDF

A High Voltage Poorer Supply for Electrostatic Precipitator with Superimposing Voltage Pulse on DC Source (펄스 및 직류 중첩형 전기집진기용 고전압 전원장치 개발 연구)

  • Kim, Jong-Soo;Rim, Geun-Hie;Lee, Sung-Jin;Kim, Seung-Min;Cho, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.624-630
    • /
    • 2001
  • The trend of the regulations on environmental issues are getting tight. Responding to this trend new technologies such as moving electrodes, wide pitch and pulsed power supply are also introduced in the electrostatic precipitator(EP) systems. The introduction of wide pitch and moving electrodes enhances the system performance of the EPs by improving air-flow and by improving the ash reentrainment on rapping. The power supplies for the EPs developed up to date include thyristor-based dc or intermittent type, SMPS(switching mode power supply) type and the pulsed-power supply type. The use of the pulsed ones is known to improve dust-collecting efficiency of high resistivity ash and reduces back corona occurrence in the collecting plate. There are two kinds of pulsed-power supplies; one with pulsed transformers and the other with direct dc switching devices. The latter uses rotary spark gap switches or semiconductor switches. Both have the merits and demerits: the spark gap switches are simple and robust but has short life time, hence, high maintenance cost, whereas the semiconductor switches have long life time but are costly. In this study, A high voltage power supply with superimposing voltage pulse on dc source was developed for EPs. This study describes circuit topology, operating principle of the scheme, and analysis of experimental results on Dong-Hae Power Plant. The pulsed power supply consists of a variable dc power supply with ratings of 60kV, 800mA and pulse generator which is made of high voltage thyristor-diode switch strings, an LC resonant tank and a blocking inductor. The pulse generator generates variable pulse-voltage up to 70kV using a high frequency resonant inverter with a variable dc source. Two prototypes were built and tested on 250MW DongHae power plant to verify the possibility of the commercial use and the normal operation in the transient states.

  • PDF

Automatic control problems of VVVF converter-based variable-frequency type air (VVVF기를 기초한 가변식기압급수설비의 자동제어 문제)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF

Ultra-fast Adaptive Frequency-controlled Hysteretic Buck Converter for Portable Devices

  • Kim, Kwang-Ho;Kong, Bai-Sun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.615-623
    • /
    • 2016
  • The paper describes a hysteretic buck converter including a differentiator and an adaptive hysteresis window controller. Differentiating the feedback signal achieves ultra-fast switching of the buck converter. The adaptive hysteresis window control allows a monotonous operation with predictable noise spectrum, and gives way to efficient design for variable supply and output voltages. The measurement results in a $0.13-{\mu}m$ CMOS process indicated that the switching frequency became double times higher, and the voltage ripple was reduced by up to 69%. They also indicated that the normalized switching frequency variation was reduced by 74% with variable $V_{DD}$ and by 63% with variable $V_{OUT}$. The power efficiency was improved by 3.5% depending on loading condition.

Driving Algorithm on Three Phase BLDC Motor Applied 4-Switch using Voltage Doubler (Voltage Doubler를 이용한 4-스위치 3상 BLDC 전동기 구동 알고리즘)

  • Yoon, Yong-Ho;Lee, Jung-Suk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.48-52
    • /
    • 2011
  • Over the years, traditionally, six-switch three-phase inverters have been widely utilized for variable speed alternating current motor drives. Recently, some efforts have been made on the application of four-switch three phase inverter for uninterruptible power supply and variable speed drives. This is due to some advantages of the four-switch three phase inverter over the conventional six-switch three-phase inverters such as reduced price due to reduction in number of switches, reduced switching losses, reduced number of interface circuits to supply logic signals for the switches, simpler control algorithms to generate logic signals, less chances of destroying the switches due to lesser interaction among switches, and less real-time computational burden. However such as slow di/dt and speed limitation, are the inherent characteristics and main drawbacks of the four-switch configuration. Those problems can be overcome in conjugation with Voltage-doublers which has additional advantage, such as unity power factor correction.

Development of PC based High Voltage Generator for Dental CT (PC기반 치과 CT용 고전압 펄스 발생장치 개발)

  • Kim, Hack-Seong;Oh, Jun-Yong;Song, Sang-Hoon;Won, Choong-Yeon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

Analysis of Input·Output Characteristics in the PWM Converter with Unbalance Supply Voltage (불평형 전원 전압을 갖는 PWM 컨버터의 입·출력 특성 분석)

  • Khoo, Ja-Kyeung;Kim, Sang-Hoon
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.203-210
    • /
    • 2005
  • The PWM(Pulse Width Modulated) converter for the AC to DC rectification has become attractive in the industrial variable-speed drive application and the electric utilities due to the following benefits: Nearly the sinusoidal input current with unity power factor; Controllable DC link voltage; Bidirectional power flow. This paper presents a quantitative analysis of single and three phase PWM converter's input and output characteristics as a function of the input filter inductance under balanced and unbalanced conditions. Also, its performance under the supply voltage including harmonics is investigated by simulation with Matlab Simlulink and experiments. These results provide a reference for selecting the reasonable converter's input filter inductance for given harmonics or power factor criterion.

  • PDF

The gate delay time and the design of VCO using variable MOS capacitance

  • Ryeo, Ji-Hwan
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.99-102
    • /
    • 2005
  • In the paper, a proposed VCO based on bondwire inductances and nMOS varactors was implemented in a standard $0.25\;{\mu}m$ CMOS process. Using the new drain current model and a propagation delay time model equations, the operation speed of CMOS gate will predict the dependence on the load capacitance and the depth of oxide, threshold voltage, the supply voltage, the channel length. This paper describes the result of simulation which calculated a gate propagation delay time by using new drain current model and a propagation delay time model. At the result, When the reverse bias voltage on the substrate changes from 0 voltage to 3 voltage, the propagation delay time is appeared the delay from 0.8 nsec to 1 nsec. When the reverse voltage is biased on the substrate, for reducing the speed delay time, a supply voltage has to reduce. The $g_m$ value of MOSFET is calculated by using new drain current model.

  • PDF