• Title/Summary/Keyword: use of radiation

Search Result 2,064, Processing Time 0.031 seconds

The Effect of Adequate Radiation Shield Production for Radiation Worker (방사선 차폐체 제작을 통한 작업종사자 피폭 감소 방안)

  • Kim, Ki;Hong, Gun-Chul;Kwak, In-Suk;Park, Sun-Myung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • Purpose: Along with recent advances in PET/CT instrumentation and imaging technology, the number of patients has also been steadily increasing. This resulted in the increased radiation exposure to radiation workers in PET/CT rooms. In this study, we installed a radiation shield and investigated whether it could reduce radiation exposure to the workers and thus enhance job satisfaction. Materials and Methods: A radiation shield is composed of 5 cm thick lead and has a structure in which a radiation worker sits and watches a patient through lead glass while injecting radiopharmaceutical to the patient. Quarterly absorbed dose of radiation workers was measured using thermoluminescence dosimeters (TLD) and the results were compared for six months each before and after installation of the radiation shield. Exposure dose was also measured using a pocket dosimeter placed at the same location in the front and the back of the radiation shield. In addition, frequency of use of the shield and job satisfaction of radiation workers were investigated using a survey. Results: Quarterly absorbed dose of radiation workers was 2.70 mSv on average before installation of new radiation shield, whereas that dropped to 2.13 mSv after installation of radiation shield, reducing radiation exposure dose by 21%. Exposure dose on the front side of the shield was 61.2 R, whereas that on the back side of shield was 2.8 R. According to the survey, 85% of workers used the shield and were satisfied with the outcome: each radiation worker made injections to patients average of 6.5 times/day and preferred sitting to standing while injecting radiopharmaceutical to patients. Conclusion: Use of radiation shield reduced the exposure dose of radiation workers, which is the ultimate goal of radiation protection to minimize radiation exposure and is an appropriate method for the improvement of hospital working environment. Furthermore, we found that use of radiation shield not only relieves physical and psychological burden of radiation workers but also enhances job satisfaction. This result indicates that use of radiation shield is important for improvement of the radiation workers' job environment in terms of radiation protection.

  • PDF

Stereotactic radiotherapy for early stage non-small cell lung cancer

  • Ricardi, Umberto;Badellino, Serena;Filippi, Andrea Riccardo
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.57-65
    • /
    • 2015
  • Stereotactic body radiotherapy (SBRT) represents a consolidated treatment option for patients with medically inoperable early stage non-small cell lung cancer (NSCLC). The clinical evidence accumulated in the past decade supports its use as an alternative to surgery with comparable survival outcomes. Due to its limited toxicity, SBRT is also applicable to elderly patients with very poor baseline pulmonary function or other severe comorbidities. Recent comparative studies in operable patients raised the issue of the possible use of SBRT also for this subgroup, with quite promising results that still should be fully confirmed by prospective trials with long-term follow-up. Aim of this review is to summarize and discuss the major studies conducted over the years on SBRT and to provide data on the efficacy and toxicity of this radiotherapy technique for stage I NSCLC. Technical aspects and quality of life related issues are also discussed, with the goal to provide information on the current role and limitations of SBRT in clinical practice.

Gonadotrophin Releasing Hormone Analogues for Ovarian Function Preservation in Young Females Undergoing Chemotherapy

  • Bansal, Anshuma;Patel, Firuza Darius;Rai, Bhavana;Dhanireddy, Bhaswanth;Sharma, Suresh Chand
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2185-2190
    • /
    • 2014
  • Chemotherapy has significantly improved the prognosis of cancer patients with various malignancies. However, female patients, especially those whoich are premenopausal, suffer from significant chemotherapy induced ovarian function impairment, which decreases their quality of life. Many new techniques for ovarian preservation have been established in recent years. Although the use of gonadotrophin releasing hormone analogues (GnRHa) for this purpose is not a new concept, its effectiveness in protection of ovarian function is still debatable. This article deals with studies and metaanalyses which have been undertaken in the past, demonstrating the impact of GnRHa in ovarian function preservation, and whether their use can be implemented in routine practice.

Correction of Dose Distribution at Total Body Irradiation using Compensator

  • Kim Jong Sik;Cho Hyun Sang;Kim Young Kon;Cho Jung Keun;Ju Sang Kyu;Park Young Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.87-93
    • /
    • 1997
  • The using of compensator is required to adjust the irregular dose distribution due to irregular thickness of the body in Total Body Irradiation. Aluminuim, copper or lead is generally used as compensator. In our study, we would like to introduce a result of the attenuation and compensation effect of radiation use compensator made by duralumin and its clinical use. The thickness of compensator was calculated by the attenustion of radiation, which was measured by polystyrene phantom and ionization chamber(farmer). The compensation effect of radiation was measured by diode detector. All of conditions were set as in real treatment, and the distanc from source to detector was 446 cm. We also made fixation of device to easily attach the compensator to LINAC. Beam spoiler was menufactured and placed on the patient to irradiate sufficient dose to the skin. diode detector were placed on head, neck, chest, umbilicus. pelvis and knee with each their entranced exit points, and datas of dose distribution were evaluated and compared in each points for eleven patients(Feb. 96-Feb. 97). The attenuation rate of irradiation by duralumin compensator was measured as $1.4\%$ in 2mm thickness. The mean attenuation rate was $1.3\%$ per 2mm as increasing the thickness gradually to 50 mm. By using duralunim compensator, dose distribution in each points of body was measured with ${\pm}2.8\%$ by diode detectior. We could easily calculate the thickness of compensator by measuring the attenuation rate of radiation, remarkably reduce the irragularity of dose distribution duo to the thickness of body and magnify the effect of radiation therapy.

  • PDF

Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management

  • Cheon, Bo Kyung;Kim, Cho Long;Kim, Ka Ram;Kang, Min Hye;Lim, Jeong Ae;Woo, Nam Sik;Rhee, Ka Young;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.31 no.4
    • /
    • pp.244-252
    • /
    • 2018
  • C-arm fluoroscopy is useful equipment in interventional pain management because it helps to guide correct needle targeting for the accurate injection and drug delivery. However, due to increased use of C-arm fluoroscopy in various pain procedures, the risk of radiation exposure is a significant concern for pain physicians. The harmful biological effects of ionizing radiation on the human body are well known. It is therefore necessary to strive to reduce radiation exposure. Lead aprons with thyroid shields are the most fundamental radiation protective devices for interventional procedures, and are very effective. However, the operator's radiation safety cannot be guaranteed because pain physicians seem to lack sufficient interest, knowledge, and awareness about radiation safety. Also, inappropriate care and use of radiation protective devices may result in a higher risk of radiation exposure. The purpose of this article was to review the literature on radiation safety with a focus on lead aprons and thyroid shields and present recommendations related to those devices during C-arm fluoroscopic-guided interventions by pain physicians.

Medical Preparedness in Radiation Accidents (방사선 사고시의 의료대책)

  • Kim, Eun-Sil;Kim, Jong-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.201-215
    • /
    • 1996
  • Radiation and radioactive materials serve man in many beneficial ways. Diagnostic X-ray, radiation therapy, and other nuclear medicine uses of radioactivity save thousands of lives each year. Industrial application of radiation, such as radiography, make many manufactured products more reliable and less expensive. Nuclear power plants are producing more electrical power each year and reducing our dependence on imported oil. However, radiation can and dose produce harmful effects particularly as the reault of a radiation accident in which a victim receives as the result of a radiation accident in which a victim receives a large dose. Fortunately such accidents are very rare and recently we need more electric power produced by nuclear power plants. Considering increase of use of radiation or radioactive materials, we have to establish the radiological emergency response system prepared for radiation accidents.

  • PDF

Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use

  • Son, Jaeman;Jung, Seongmoon;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.159-164
    • /
    • 2021
  • Purpose: We investigated the properties of CLEANBOLUS based on silicone with suitable characteristics for clinical use. Methods: We evaluated the characteristics of CLEANBOLUS and compared the results with the commercial product (Super-Flex bolus). Also, we conducted physical evaluations, including shore hardness, element composition, and elongation break. Transparency was investigated through the measured absorbance within the visible region (400-700 nm). Also, dosimetric characteristics were investigated with surface dose and beam quality. Finally, the volume of unwanted air gap was investigated based on computed tomography images for breast, chin, and nose using Super-Flex bolus and CELANBOLUS. Results: CLEANBOLUS showed excellent physical properties for a low shore hardness (000-35) and elongation break (>1,000%). Additionally, it was shown that CLEANBOLUS is more transparent than Super-Flex bolus. Dosimetric results obtained through measurement and calculation have an electron density similar to water in CLEANBOLUS. Finally, CLEANBOLUS showed that the volume of unwanted air gap between the phantom and each bolus is smaller than Super-Flex bolus for breast, chin, and nose. Conclusions: The physical properties of CLEANBOLUS, including excellent adhesive strength and lower shore hardness, reduce unwanted air gaps and ensure accurate dose distribution. Therefore, it would be an alternative to other boluses, thus improving clinical use efficiency.

Comment on "Estimation of Net Radiation in Three Different Plant Functional Types in Korea" (한국의 세 개의 다른 식생기능형태에서의 순복사 추정 논문에 대한 의견)

  • Kang, Min-Seok;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.3
    • /
    • pp.118-122
    • /
    • 2009
  • Net Radiation ($R_N$) is the major driving force for biophysical and biogeochemical processes in the terrestrial ecosystems, which is one of the most critical variables in both measurement and modeling. Despite its importance, there are only 10 weather stations conducting $R_N$ measurements among the 544 stations operated by Korea Meteorological Administration (KMA; KMA, 2008). The measurement of incoming shortwave radiation ($R_S{\downarrow}$) is, however, conducted at 22 stations while that of sunshine duration is conducted at all the manned stations. In this context, the recent research for estimating $R_N$ using $R_S{\downarrow}$ in Korean peninsula by Kwon (2009) is of great worth. The author used a linear regression and the radiation balance methods. We generally agree with the author that, in terms of simplicity and practicality, both methods show reliable applicability for estimating $R_N$. We noted, however, that the author's experimental method and analysis need some clarification and improvement, that are addressed in the following perspectives: (1) the use of daily integrated data for regression, (2) the use of measured albedo, (3) the use of linear coefficients for whole year data, (4) methodological improvement, (5) the use of sunshine duration, and (6) the error assessment.

DNA Damage of Lymphocytes in Volunteers after 4 hours Use of Mobile Phone (일부 자원자들의 이동전화 4시간 연속 사용 후 림프구 DNA 손상 평가)

  • Ji, Seon-Mi;Oh, Eun-Ha;Sul, Dong-Geun;Choi, Jae-Wook;Park, Hee-Chan;Lee, Eun-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.373-380
    • /
    • 2004
  • Objectives : There has been gradually increasing concern about the adverse health effects of electromagnetic radiation originating from cell phones which are widely used in modern life. Cell phone radiation may affect human health by increasing free radicals of human blood cells. This study has been designed to identify DNA damage of blood cells by electromagnetic radiation caused by cell phone use. Methods : This study investigated the health effect of acute exposure to commercially available cell phones on certain parameters such as an indicator of DNA damage for 14 healthy adult volunteers. Each volunteer during the experiment talked over the cell phone with the keypad facing the right side of the face for 4 hours. The single cell gel electrophoresis assay (Comet assay), which is very sensitive in detecting the presence of DNA strand-breaks and alkali-labile damage in individual cells, was used to assess peripheral blood cells (T-cells, B-cells, granulocytes) from volunteers before and after exposure to cell phone radiation. The parameters of Comet assay measured were Olive Tail Moment and Tail DNA %. Results : The Olive Tail Moment of B-cells and granulocytes and Tail DNA % of B-cells and granulocytes were increased by a statistically significant extent after 4-hour use of a cell phone compared with controls. Conclusion : It is concluded that cell phone radiation caused the DNA damage during the 4 hours of experimental condition. Nonetheless, this study suggested that cell phone use may increase DNA damage by electromagnetic radiation and other contributing factors.

Actual Use of Internet in Curriculum Study of Students in Radiology (방사선 재학생 전공교과목 학습에서 인터넷 활용 실태)

  • Kim, Min-Cheol;Huang, Yuxin;Choi, Ji Hoon;Jung, Hong Ryang;Park, Hae-Ri;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.487-491
    • /
    • 2018
  • The purpose of this study was to analyze questionnaires of 161 college students attending radiology departments in order to investigate the actual condition of internet use of radiology students. As a result, 95% of college students using the Internet showed 5.8% of general knowledge, 56.9% of radiation major, and 45.8% of general education. In the field of Internet use, basic medicine was 71.2%, anatomy 59.5% and physiology 51.6%. Radiation theory was 39.9% in radiation physics, 31.4% in radiation biology, and 18.3% in radiation management. The radiological applications were followed by radiography and radiography in order of 31.4% and 20.3%, respectively. The radiological imaging was 45.8%, MRI was 37.9%, CT was 37.3%, ultrasound was 24.2%, And radiation nuclear medicine 25.5%. The results of the descriptive statistics of the satisfaction of the contents using the Internet media showed that the overall satisfaction was below 2.5 Based on the results of this study, it is necessary to develop a program with high accessibility to provide various opportunities for internet-based opportunities to increase the academic achievement value of major subjects through the internet and to solve the difficulties in the major subject.