The Effect of Adequate Radiation Shield Production for Radiation Worker

방사선 차폐체 제작을 통한 작업종사자 피폭 감소 방안

  • Kim, Ki (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Hong, Gun-Chul (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Kwak, In-Suk (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Park, Sun-Myung (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Choi, Choon-Ki (Department of Nuclear Medicine, Samsung Medical Center) ;
  • Seok, Jae-Dong (Department of Nuclear Medicine, Samsung Medical Center)
  • 김기 (삼성서울병원 핵의학과) ;
  • 홍건철 (삼성서울병원 핵의학과) ;
  • 곽인석 (삼성서울병원 핵의학과) ;
  • 박선명 (삼성서울병원 핵의학과) ;
  • 최춘기 (삼성서울병원 핵의학과) ;
  • 석재동 (삼성서울병원 핵의학과)
  • Received : 2010.09.01
  • Accepted : 2010.09.15
  • Published : 2010.10.30

Abstract

Purpose: Along with recent advances in PET/CT instrumentation and imaging technology, the number of patients has also been steadily increasing. This resulted in the increased radiation exposure to radiation workers in PET/CT rooms. In this study, we installed a radiation shield and investigated whether it could reduce radiation exposure to the workers and thus enhance job satisfaction. Materials and Methods: A radiation shield is composed of 5 cm thick lead and has a structure in which a radiation worker sits and watches a patient through lead glass while injecting radiopharmaceutical to the patient. Quarterly absorbed dose of radiation workers was measured using thermoluminescence dosimeters (TLD) and the results were compared for six months each before and after installation of the radiation shield. Exposure dose was also measured using a pocket dosimeter placed at the same location in the front and the back of the radiation shield. In addition, frequency of use of the shield and job satisfaction of radiation workers were investigated using a survey. Results: Quarterly absorbed dose of radiation workers was 2.70 mSv on average before installation of new radiation shield, whereas that dropped to 2.13 mSv after installation of radiation shield, reducing radiation exposure dose by 21%. Exposure dose on the front side of the shield was 61.2 R, whereas that on the back side of shield was 2.8 R. According to the survey, 85% of workers used the shield and were satisfied with the outcome: each radiation worker made injections to patients average of 6.5 times/day and preferred sitting to standing while injecting radiopharmaceutical to patients. Conclusion: Use of radiation shield reduced the exposure dose of radiation workers, which is the ultimate goal of radiation protection to minimize radiation exposure and is an appropriate method for the improvement of hospital working environment. Furthermore, we found that use of radiation shield not only relieves physical and psychological burden of radiation workers but also enhances job satisfaction. This result indicates that use of radiation shield is important for improvement of the radiation workers' job environment in terms of radiation protection.

PET/CT 기기의 발달과 대중화에 따라 검사 건수도 꾸준히 증가하고 있다. 이는 방사선 작업종사자의 피폭 선량도 함께 증가시키는 결과를 초래한다. 본 연구에서는 방사선 차폐체를 제작하여 방사선 작업종사자의 피폭 감소를 확인하고 또한 작업종사자의 업무 만족도 향상의 정도를 알아보고자 하였다. 차폐체 내부는 5 cm의 납이 들어 있고 작업 종사자가 앉아서 납창으로 환자를 주시하면서 주사할 수 있는 구조로 제작하였다. 새로운 차폐체 제작 전, 후 각 6개월 간 방사선 작업종사자의 분기 별 심부 피폭선량을 열형광 선량계를 이용하여 비교하고 차폐체 전면과 후면의 동일한 위치에 포켓 선량계를 위치하여 방사선 조사선량을 측정하여 비교하였다. 그리고 설문 조사를 통하여 PET/CT 작업 종사자들의 업무시 차폐체의 활용, 업무 정도, 업무 만족도 등을 조사하였다. 차폐체 제작 전의 방사선 작업 종사자의 분기 당 심부선량은 평균 2.70 mSv였으며, 방사선 차폐체 사용 후의 분기 당심부선량은 2.13 mSv로 21%의 피폭 저감효과가 나타났다. 또한 차폐체 전면의 방사선 조사선량은 분기 당 61.2 R이었고, 차폐체 후면에서는 2.8 R으로 나타났다. 설문 조사 결과종사자의 85%는 차폐체를 잘 활용한다고 하였으며, 입식보다 좌식 주사 방법에 85%의 만족도를 보였다. 차폐체의 제작, 활용 후 방사선 작업 종사자의 피폭이 감소되었으며, 이는 방사선 방호의 궁극의 목적인 방사선 피폭을 최소화 할 수 있는 병원의 근무환경과 가장 부합되는 방법이라고 생각된다. 또한 차폐체 활용이 방사선 작업 종사자의 물리적, 심리적 부담감을 경감시키고, 업무 만족도 향상에 기여한다는 것을 알 수 있었다. 이번 연구를 통해서 방사선 방호측면에서 차폐체의 제작, 활용 방안이 작업 종사자의 업무 환경에 중요한 인자임을 알려주는 좋은 결과로 사료된다.

Keywords