• Title/Summary/Keyword: upper plane

Search Result 596, Processing Time 0.025 seconds

Characteristics of Skeletodental Pattern in High Angle Cases (수직적으로 긴 안모의 두부방사선계측학적 특징)

  • Kim, Sang-Cheol;Kang, Kyung-Wha;Lee, Kyung Whan
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.937-946
    • /
    • 1998
  • The patient with an anterior open bite has one of the most difficult orthodontic problem to correct. Previous studies have yielded different conclusions as to exactly where the morphologic problems associated with vertical dysplasia-high angle cases are located. In order to identify the cephalometric features of high angle cases and highlight the measurements that characterize high angle cases, 109 pretreatment cephalograms, 35 high angle, 37 average angle, and 37 low angle cases, were analyzed and compared statistically. As the mandibular plane was steeper, the anterior facial height, especially lower anterior facial height, became greater, and the posterior facial height became smaller. All the dentoalveolar vertical dimensions, especially in upper, increased. And all the skeletal angular measurements increased. Especially Lower genial angle had most positive correlation to mandibular Plane angle. Upper incisor was lingually inclined, and lower incisor was labially inclined in high angle cases.

  • PDF

A STUDY ON NASAL RESPIRATORY PATENCY IN THE GROWING CHILDREN WITH ANTERIOR CROSSBITE (전치부 반대교합 아동의 비강통기도에 관한 연구)

  • Ahn, Soon Chan;Suhr, Cheong Hoon
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.179-203
    • /
    • 1992
  • This study was designed to analyze nasal respiratory patency and its correlation with skeletal components in growing children with anterior crossbite. The subjects consisted of 40 control patients, 24 nose breathers with anterior crossbite and 18 mouth breathers with anterior crossbite. The mean age was 11.4 years in the control group, 10.1 years in nose breathing group and 9.5 years in mouth breathing group. The results were as follows, 1. In anterior cross bite group, and nasal respiratory airflow rates (N.R.A.R.) was significantly lower than that of control group regardless of nasal decongestants application. 2. The N.R.A.R. of mouth breathers with anterior crossbite in male group was significantly lower than that of mouth breathers, but increased to the level of control group after nasal decongestants application. But in female group, the N.R.A.R. was significantly lower in mouth breathing group at both conditions. 3. Mouth breathing group showed smaller anterior vertical nasal cavity height (ANS-ANS'), lower upper anterior facial height ratios (N-sp'/N-Me) and higher maxillary occlusal plane ratios (OL-ML/ML-NL) than those of nose breathing group with anterior crossibte. 4. Items showing nasal height (ANS-ANS', PNS-PNS'), anterior upper facial height (N-sp') was were strongly correlated with N.R.A.R. at 150 pascal in inspiration. But item showing maxillary occlusal plane ratios (OL-ML/ML-NS) was negatively correlated with N.R.A.R. at 150 pascal in inspiration. 5. There were forward tongue position in mouth breathing group, but it was not significantly correlated with N.R.A.R. at 150 pascal in inspiration.

  • PDF

The usability of the image according to the frequency encoding gradient direction conversion in fixation using the non magnetic metal screw (비 자성 금속 screw를 이용한 고정술에서 주파수 부호화 경사 방향 변환에 따른 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-So
    • Journal of Digital Contents Society
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Because of causing the geometrical transformation of the magnetic field, the patient implementing the fixation using the nonmagnetic metal screw causes the magnetic susceptibility artifact at an image. Thus, in this research, the distortion measure of the image according to the frequency oblique direction conversion tried to be compared in the magnetic susceptibility artifact occurence. First, the itself phantom inserting the nonmagnetic metal screw of the titanium component was made and the region of interest was set up and the frequency oblique direction the anterior - back side was converted to the right-to-left direction in the axial image and a right-to-left was converted to the upper side - bottom side in the coronal plane and the upper - bottom side was converted to the anterior - back side in the sagittal plane and the distortion measure of the region of interest was compared, it observed. In a result, when converting the frequency oblique direction, the distortion difference of the region of interest could be confirmed and it is considered to enhance the diagnostics efficiency changing the oblique direction appropriately.

Displacement pattern of the anterior segment using antero-posterior lingual retractor combined with a palatal plate

  • Seo, Kyung-Won;Kwon, Soon-Yong;Kim, Kyung A;Park, Ki-Ho;Kim, Seong-Hun;Ahn, Hyo-Won;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.289-298
    • /
    • 2015
  • Objective: To evaluate and compare the effects of two appliances on the en masse retraction of the anterior teeth anchored by temporary skeletal anchorage devices (TSADs). Methods: The sample comprised 46 nongrowing hyperdivergent adult patients who planned to undergo upper first premolar extraction using lingual retractors. They were divided into three groups, based on the lingual appliance used: the C-lingual retractor (CLR) group (group 1, n = 16) and two antero-posterior lingual retractor (APLR) groups (n = 30, groups 2 and 3). The APLR group was divided by the posterior tube angulation; posterior tube parallel to the occlusal plane (group 2, n = 15) and distally tipped tube (group 3, n = 15). A retrospective clinical investigation of the skeletal, dental, and soft tissue relationships was performed using lateral cephalometric radiographs obtained pretreatment and post en masse retraction of the anterior teeth. Results: All groups achieved significant incisor and canine retraction. The upper posterior teeth did not drift significantly during the retraction period. The APLR group had less angulation change in the anterior dentition, compared to the CLR group. By changing the tube angulation in the APLR, the intrusive force significantly increased in the distally tipped tube of group 3 patients and remarkably reduced the occlusal plane angle. Conclusions: Compared to the CLR, the APLR provides better anterior torque control and canine tipping while achieving bodily translation. Furthermore, changing the tube angulation will affect the amount of incisor intrusion, even in patients with similar palatal vault depth, without the need for additional TSADs.

A Study on Verification Tests according to Connection Design Methods of Steel Plate Concrete Structures (강판 콘크리트 구조 접합부의 설계방식에 따른 검증실험 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Yang, Hyun Jung;Kim, Won Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • In this study, out-of-plane flexural test was performed to analyze behavior properties for a beam specimen which imitated a structure with connection member between reinforced concrete and steel plate concrete part. Tie bars between a upper and a lower steel plate, and tie wide flange shapes between upper and lower ribs were designed to prevent the steel plate or the ribs from breakaway in the connection of the specimen. As a result of the test, ductile failure behavior of the specimen and the functionality of the tie members were conformed as originally intended. Also, tension tests were performed to evaluate the design appropriateness of two specimens produced to anchor and connect mechanically #14 bars. The two test results showed that the anchorage connection system behaves in elastic limit during the main bars yielded, and the integrity of the designed system was verified.

Clinical effectiveness of different types of bone-anchored maxillary protraction devices for skeletal Class III malocclusion: Systematic review and network meta-analysis

  • Wang, Jiangwei;Yang, Yingying;Wang, Yingxue;Zhang, Lu;Ji, Wei;Hong, Zheng;Zhang, Linkun
    • The korean journal of orthodontics
    • /
    • v.52 no.5
    • /
    • pp.313-323
    • /
    • 2022
  • Objective: This study aimed to estimate the clinical effects of different types of bone-anchored maxillary protraction devices by using a network meta-analysis. Methods: We searched seven databases for randomized and controlled clinical trials that compared bone-anchored maxillary protraction with tooth-anchored maxillary protraction interventions or untreated groups up to May 2021. After literature selection, data extraction, and quality assessment, we calculated the mean differences, 95% confidence intervals, and surface under the cumulative ranking scores of eleven indicators. Statistical analysis was performed using R statistical software with the GeMTC package based on the Bayesian framework. Results: Six interventions and 667 patients were involved in 18 studies. In comparison with the tooth-anchored groups, the bone-anchored groups showed significantly more increases in Sella-Nasion-Subspinale (°), Subspinale-Nasion-Supramentale(°) and significantly fewer increases in mandibular plane angle and the labial proclination angle of upper incisors. In comparison with the control group, Sella-Nasion-Supramentale(°) decreased without any statistical significance in all treated groups. IMPA (angle of lower incisors and mandibular plane) decreased in groups with facemasks and increased in other groups. Conclusions: Bone-anchored maxillary protraction can promote greater maxillary forward movement and correct the Class III intermaxillary relationship better, in addition to showing less clockwise rotation of mandible and labial proclination of upper incisors. However, strengthening anchorage could not inhibit mandibular growth better and the lingual inclination of lower incisors caused by the treatment is related to the use of a facemask.

CORRELATIONS BETWEEN ORBICULARIS ORIS AND MENTALIS MUSCLE ACTIVITY AND CRANIOFACIAL MORPHOLOGY IN NORMAL OCCLUSION AND CLASS III MALOCCLUSION (정상교합자와 3급 부정교합자에서 구륜근과 턱끝근의 활성과 안면골격 사이의 상관성에 관한 연구)

  • Chang, Chun Sil;Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.253-271
    • /
    • 1992
  • The purpose of this study was to investigate the difference of EMG activity of the Orbicularis oris and Mentalis muscle between normal occlusion and class III malocclusion group during various lip position and to find out whether any correlations exist between the muscular activity and craniofacial morphology. In this study, 50 subjects with a mean age of 22.9 Years (range 20.0-26.0) were investigated (25 subjects were normal occlusion, and 25 subjects were class III malocclusion). EMG data were recorded from the Orbicularis oris and Mentalis muscle during rest lip posture, lip position at maximum biting, lip position at maximum sealing effort, lip position at chewing, swallowing and phonation with the Medelec MS-25 electromyographic machine. Lateral cephalometric radiographs was taken with the mandible in intercuspal position on all subjects. All data were recorded and statistically processed. The findings of this study can be summerized as follows: 1. In normal occlusion, the maximal mean amplitude of upper lip during the lip position at chewing was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 2. In Class III malocclusion, the maximal mean amplitude of upper lip during the lip position at chewing, swallowing and phonation was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 3. Compare to normal occlusion, the Class III malocclusion was showed low maximal mean amplitude of upper lip during rest lip posture and the lip position at swallowing of saliva, and showed great maximal mean amplitude of lower lip and meantalis muscle during the lip position at chewing and phonation. 4. In normal occlusion, the maximal mean amplitude of upper lip during various lip position was not correlated with the length and thickness of upper lip, but the maximal mean amplitude of lower lip during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip. 5. In Class III malocclusion, the maximal mean amplitude of upper lip during rest lip posture was negatively correlated with the thickness of upper lip, and the maximal mean amplitude of lower lip and mentalis muscle during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not correlated with the cephalometric measurements of soft tissue. 6. The correlation between the maximal mean amplitude of orbicularis oris and mentalis muscle and cephalometric measurements of incisors was not nearly present. 7. In normal occlusion, the maximal mean amplitude of lower lip and mentalis muscle during the lip position at maximum biting was negatively correlated with the angle between palatal plane and mandibular plane. In Class III malocclusion, the maximal mean amplitude of upper lip, lower lip and mentalis muscle during function was negatively correlated with the length of maxilla, the maximal mean amplitude of upper lip and lower lip during function was negatively correlated with the SNA and SNPo, and the maximal mean amplitude of lower lip during the lip position at chewing was negatively correlated with the ANB.

  • PDF

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

  • Dae-Sung Kim;So-Hyung Park;Jong-Ju Ahn;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.271-280
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS. Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS. Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION. In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.

Effect of Shoulder Position on Scapular Muscle Activity during Scapular Protraction

  • Yun, Sung Joon;Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.3
    • /
    • pp.157-162
    • /
    • 2020
  • Purpose: This study was to evaluate several tasks performed at a high intensity in terms of their ability to elicit EMG activity in the serratus anterior by comparing the EMG activities of the serratus anterior, upper trapezius, and lower trapezius muscles during six tasks combined shoulder flexion with rotation. Methods: Fifteen healthy males were recruited to this study. Each subject was instructed to assume a sitting position without back support and asked to flex (90° or 120°) the right shoulder and protract the scapula in the sagittal plane with maximal external rotation; to assume a neutral position; or to internally rotate the glenohumeral joint. The EMG data were collected from the serratus anterior (SA), upper trapezius (UT), and lower trapezius (LT) muscles were normalized to maximum voluntary isometric contraction. The UT/LT and UT/SA muscle activity ratios in each task were assessed by calculating the surface EMG. Data were analyzed by two-way repeated-measures analysis of variance, with the level of significance set at p<0.05. Results: The results of this study, shoulder flexion with external rotation resulted in low upper trapezius/serratus anterior and upper trapezius/lower trapezius ratios and a relatively high level of serratus anterior activation. Conclusion: Shoulder flexion with external rotation used herein may be considered as important for clinical interventions aimed at selectively increasing SA strengthen and clinical selection of exercises for improving glenohumeral joint and scapulothoracic control.

Technical Design of Tight Upper Sportswear based on 3D Scanning Technology and Stretch Property of Knitted Fabric (3차원 스캔 기술과 니트 소재의 신축성을 적용한 밀착형 스포츠웨어 상의 설계)

  • Kim, Tae-Gyou;Park, Soon-Jee;Park, Jung-Whan;Suh, Chu-Yeon;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.277-285
    • /
    • 2012
  • This research studied how to develop tight upper sportswear from 3D scan data considering fabric stretch property. Subjects were five Korean men of average figure in their 20's. Scanning was done for ten postures via vitus smart/pro(Techmath LTD). Analyzing from 3D scan data, more than 70% of the upper body surface showed surface change rate under 20%. It was shoulder and under arm side part that showed most noticeable body surface change when moving. A parametric model with convex surface was generated and flattened onto the plane, resulting 2D pattern. The error rate occurring in the process of 3D to 2D conversion was 0.2% for outline and 0.13% for area, respectively. Thirteen kinds of stretchable fabrics in the market were collected for this study. Stretch property was in the range of 16.0~58.2% for wale direction; 23.1~78.4% for course. Based on wear trial test, four fabrics were chosen for making the 1st experimental garment and finally one fabric was chosen for the 2nd one, which was developed applying 4 kinds of crosswise reduction rate on 2D pattern: 0, 5, 10, and 15%. Through wear trial test and garment pressure measurement, experimental garment applied with 10% pattern reduction rate was evaluated as most comfortable and considerable.