DOI QR코드

DOI QR Code

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

  • Dae-Sung Kim (Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital) ;
  • So-Hyung Park (Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University) ;
  • Jong-Ju Ahn (Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University) ;
  • Chang-Mo Jeong (Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital) ;
  • Mi-Jung Yun (Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital) ;
  • Jung-Bo Huh (Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital) ;
  • So-Hyoun Lee (Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital)
  • Received : 2023.07.25
  • Accepted : 2023.10.06
  • Published : 2023.10.31

Abstract

PURPOSE. This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS. Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS. Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION. In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.

Keywords

Acknowledgement

This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) (NRF2020R1F1A1076283).

References

  1. Nagy WW, Goldstein GR. Facebow use in clinical prosthodontic practice. J Prosthodont 2019;28:772-4.  https://doi.org/10.1111/jopr.12944
  2. Ma L, Liu F, Mei J, Chao J, Wang Z, Shen J. A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device. J Adv Prosthodont 2023;15:11-21.  https://doi.org/10.4047/jap.2023.15.1.11
  3. Palaskar JN, Joshi N, Gullapalli P, Shah P. Comparative evaluation of sagittal inclination of the occlusal plane with Frankfort horizontal plane in facebow transfers to semiadjustable and fully adjustable articulators. J Prosthet Dent 2020;123:299-304.  https://doi.org/10.1016/j.prosdent.2018.12.024
  4. Maveli TC, Suprono MS, Kattadiyil MT, Goodacre CJ, Bahjri K. In vitro comparison of the maxillary occlusal plane orientation obtained with five facebow systems. J Prosthet Dent 2015;114:566-73.  https://doi.org/10.1016/j.prosdent.2015.02.030
  5. Afsharzand Z, Rashedi B, Petropoulos VC. Communication between the dental laboratory technician and dentist: work authorization for fixed partial dentures. J Prosthodont 2006;15:123-8.  https://doi.org/10.1111/j.1532-849X.2006.00086.x
  6. Weston JF, Haupt E. Creating aesthetic success through proper clinician and laboratory technical communication. Dent Clin North Am 2011;55:371-82.  https://doi.org/10.1016/j.cden.2011.01.007
  7. Samet N, Smidt A, Samet N, Weiss EI. A clinical and cost-benefit evaluation of five facebows. Quintessence Int 2002;33:511-5. 
  8. Palik JF, Nelson DR, White JT. Accuracy of an earpiece face-bow. J Prosthet Dent 1985;53:800-4.  https://doi.org/10.1016/0022-3913(85)90160-X
  9. Japatti SR, Engineer PJ, Reddy BM, Tiwari AU, Siddegowda CY, Hammannavar RB. Anthropometric assessment of the normal adult human ear. Ann Maxillofac Surg 2018;8:42-50.  https://doi.org/10.4103/ams.ams_183_17
  10. Leukhardt M. Transferring esthetically relevant facial reference lines to the articulator. J Craniomandib Func 2010;2:311-28. 
  11. Lee SH, Jeong CM, Yun MJ, Huh JB, Lee SH. Treatment of upper and lower 3D printing CAD-CAM dentures using the POP (PNUD Occlusal Plane) Bow system, a prefabricated occlusal plane transfer device: A case report. J Korean Acad Prosthodont 2023;61:44-54.  https://doi.org/10.4047/jkap.2023.61.1.44
  12. Park D, Bae E, Jung I, Jeong C, Yun M, Huh J, Lee S. 3D printed interim immediate denture by using the occlusal plane digital transfer method of the POP BOW system in a patient planning to extract upper and lower residual teeth: a case report. J Dent Rehabil Appl Sci 2022;38:178-88.  https://doi.org/10.14368/jdras.2022.38.3.178
  13. Tak SM, Jeong CM, Huh JB, Lee SH, Yun MJ. Full-mouth rehabilitation with increasing vertical dimension on the patient with severely worn-out dentition and orthognathic surgery history: A case report. J Korean Acad Prosthodont 2023;61:33-43.  https://doi.org/10.4047/jkap.2023.61.1.33
  14. Lee JY, Jeong CM, Huh JB, Lee SH, Yun MJ. Full mouth rehabilitation of an edentulous patient with fixed full-arch implant-supported prostheses: a case report. J Implantol Appl Sci 2022;26:234-42.  https://doi.org/10.32542/implantology.2022023
  15. Jeong YS, Jeong CM, Yun MJ, Lee SH, Huh JB. Implant-assisted removable partial denture using milledbar and attachment in partially edentulous maxilla: A case report. J Korean Acad Prosthodont 2022;60:412-9.  https://doi.org/10.4047/jkap.2022.60.4.412
  16. The Glossary of Prosthodontic Terms: Ninth edition. J Prosthet Dent 2017;117:e1-105.  https://doi.org/10.1016/j.prosdent.2016.12.001
  17. Al Quran FA, Hazza'a A, Al Nahass N. The position of the occlusal plane in natural and artificial dentitions as related to other craniofacial planes. J Prosthodont 2010;19:601-5.  https://doi.org/10.1111/j.1532-849X.2010.00643.x
  18. Chaturvedi S, Thombare R. Cephalometrically assessing the validity of superior, middle and inferior tragus points on ala-tragus line while establishing the occlusal plane in edentulous patient. J Adv Prosthodont 2013;5:58-66.  https://doi.org/10.4047/jap.2013.5.1.58
  19. Shaikh SA, K L, Mathur G. Relationship between occlusal plane and three levels of ala tragus line in dentulous and partially dentulous patients in different age groups: a pilot study. J Clin Diagn Res 2015;9:ZC39-42.  https://doi.org/10.7860/JCDR/2015/11820.5575
  20. Hatzi P, Millstein P, Maya A. Determining the accuracy of articulator interchangeability and hinge axis reproducibility. J Prosthet Dent 2001;85:236-45.  https://doi.org/10.1067/mpr.2001.10998
  21. Maveli TC, Suprono MS, Kattadiyil MT, Goodacre CJ, Bahjri K. In vitro comparison of the maxillary occlusal plane orientation obtained with five facebow systems. J Prosthet Dent 2015;114:566-73.  https://doi.org/10.1016/j.prosdent.2015.02.030
  22. Bamber MA, Firouzal R, Harris M, Linney A. A comparative study of two arbitrary face-bow transfer systems for orthognathic surgery planning. Int J Oral Maxillofac Surg 1996;25:339-43.  https://doi.org/10.1016/S0901-5027(06)80025-1
  23. Preston JD. A reassessment of the mandibular transverse horizontal axis theory. J Prosthet Dent 1979;41:605-13.  https://doi.org/10.1016/0022-3913(79)90054-4
  24. Morneburg TR, Proschel PA. Impact of arbitrary and mean transfer of dental casts to the articulator on centric occlusal errors. Clin Oral Investig 2011;15:427-34.  https://doi.org/10.1007/s00784-010-0395-9
  25. Ahlers MO, Edelhoff D, Jakstat HA. Reproduction accuracy of articulator mounting with an arbitrary facebow vs. average values-a controlled, randomized, blinded patient simulator study. Clin Oral Investig 2019;23:1007-14.  https://doi.org/10.1007/s00784-018-2499-6
  26. Farias-Neto A, Dias AH, de Miranda BF, de Oliveira AR. Face-bow transfer in prosthodontics: a systematic review of the literature. J Oral Rehabil 2013;40:686-92. https://doi.org/10.1111/joor.12081