• Title/Summary/Keyword: Dental articulator

Search Result 49, Processing Time 0.025 seconds

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

Full Adjustable Articulator (전조절성 교합기)

  • Yoon, Chang-Keun;Cho, Young-Hak;Ho, Key-Young
    • The Journal of the Korean dental association
    • /
    • v.21 no.10 s.173
    • /
    • pp.793-797
    • /
    • 1983
  • The aim of this article is to review the literature concerning the general aspects of a fully adjustable articulator. A computer can play back when the informations are put into the computer and programmed. A fully adjustable articulator is a computer like device. Even though the fully adjustable articulator is designed precisely, it can not work without inputing the informations and programming into the articulator. That is the reason why various factors controlling the mandibular movements should be recorded and duplicated on articulator avoiding the possible errors.

  • PDF

An Experimental study on the gap of movement by the hinge articulator (단순교합기에 의한 하악운동의 오차에 대한 실험적 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

A Study of Simple Hinge Articulator Mounting Method (단순접번 교합기의 모형부착 방법에 관한 연구)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.95-102
    • /
    • 2003
  • The purpose of this study was to show occlusion on the simple hinge articulator optionally mounted. Modelling of upper-lower jaw and simple hinge articulator were developed. This modelling of upper-lower jaw inserting wax bite was mounted imaginary on the modelling of simple hinge articulator by use of the computer simulation. From changes of THA(transverse horizontal axis)-incisor distance, Balkwill angle and THA deviation, eight types were mounted respectively. After removal of wax bite, upper-lower jaw position changing were compared with centric jaw relation. The results were as follows: 1. The change of THA-incisor distance had influence on mostly a vertical shift of upper jaw. 2. The change of Balkwill angle had influence on mostly a horizontal shift of upper jaw. 3. Inferior type in the THA deviations was the least shift of upper jaw. The above results suggest that the simple hinge articulator optionally mounted effect a shift of upper jaw.

  • PDF

THE COMPARATIVE STUDY FOR OCCLUSAL PLANE BETWEEN ARTICULATED CAST MODEL AND CEPHALOGRAM IN ORTHOGANTIHIC SURGERY PATIENTS (악교정수술 환자에서 교합기 석고 모형과 측면두부방사선사진의 교합평면에 관한 비교 연구)

  • Seo, Kyung-Suk;Park, Mi-Hwa;Lee, Ju-Hyun;Kim, Chul-Hwan;Chae, Jong-Moon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.239-244
    • /
    • 2003
  • The common errors in preoperative treatment plan for the orthognathic surgery can be occurred during cast impression, cast mounting procedure with face-bow transfer, surgical stent fabrication, and so on. One of the most common errors exists during mounting process of the model on the articulator. Accurate mounting of dental casts to articulator should be achieved by transferring the 3-dimensional spatial relationship of the maxillary arch to an articulator. A face-bow is used for transfer this relationship to articulator, usually by relating the face-bow to a plane of reference of maxillary cast. The purpose of this study is evaluation of the accuracy of face-bow transferring of maxillary model to the articulator. The maxillary casts of thirty patients for orthognathic surgery were mounted on articulator with an face-bow instrument. The relationship of occlusal plane angle to Frankfort horizontal plane relations were compared the cephalogram with the cast-mounted articulator. As a result of this study, the significant difference between the maxillary occlusal planes angle in the cephalogram and articulator were found. The results were followed, 1. The mean occlusal plane angle in cast-mounted articulator was $13.5^{\circ}\;(SD{\pm}5.4)$. 2. The mean occlusal plane angle in cephalogram was $10.4^{\circ}\;(SD{\pm}4.3)$. 3. The mean difference of occlusal plane angle between cast-mounted articulator and cephalogram was $3.3^{\circ}\;(SD{\pm}4.6)$. According to the result, we should suggest that the occlusal plane angle to Frankfort plane in cast-mounted articulator is more steeper than that of cephalogram. And then, maxillofacial surgeon should try to get a more predictable result by suggesting the proper correction method and mounting the cast accurately.

A Comparative Sudy on Accuracy of Occlusal Plane Angle on Mounting The Hanau 96-H2 Articulator (Hanau 96-H₂교합기에 상악 모형 부착시 교합면 경사각에 대한 비교 연구)

  • Hwang, Hie-Seong;Lee, Ho-Yong
    • The Journal of the Korean dental association
    • /
    • v.25 no.9 s.220
    • /
    • pp.861-872
    • /
    • 1987
  • The Purpose of this study was to know the differences between the occlusal plane angles formed by F-H plane on cephalograms and the occlusal plane angles by the upper margin of the articulator, and to ind the contributing factors to the difference of occlusal angles. for this study, 39 young adults (20 men, 19 women) were selected who had normal occlusion, no severe attrition, no missing tooth, not been under orthodontic treatment and occlusal equilibration and no temporomandibular disorders. The maxillary casts were mounted with Hanau 159-1 ear piece type face-bow and measured the occlusal plane angle with prototype occlusal plane projector. The following results were obtained; 1. The mean value of the ear rod F-H plane occlusal angle was 14.75˚, articulator occlusal angle was 9.26˚ and strong positive correlation between these angles, 2. It was almost same angle between the ear rod F-H plane angle (14.75˚) and the beyron point to infraorbital rim-6mm. occlusal angle (14.46˚) 3. The mean distance from the ear rod porion to the Byron point was 5.67mm. 4. It was no significant correlation between the distances Po-Beyron point, Or-infraorbital rim and articulator occlusal angle.

  • PDF

A Study of the Hinge Axis Point (Hinge Axis Point에 관한 연구)

  • Jung, Kum-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.72-78
    • /
    • 1984
  • The notion that the axis of the shaft of the articulator must coincide the patient's mandibular transverse axis tells us the importance of locating the axis precisely. When using kinematic axis to transfer a cast to an articulator, the anatomic asymmetry of the contralateral points will result in certain distortion when the axis transferred to an articulator where the mechanical axis produces symmetry. In this study, after locating the true hinge axis point with Denar hinge axis locator, the discrepancies between true hinge axis point and arbitrary hinge axis point that was 13mm anterior from the posterior margin of center of trangus to the outer canthus of eye were measured. And the discrepancies between left and right true hinge axis point in the superoinferior and anteroposterior directions were measured. For this study, 20 dental students who have no missing teeth and no difficulties of mandibular movement were selected. Upper and lower cast of subjects were mounted on Denar Mark II articulator uisng Denar Slidematic face-bow and centric relation record for the measurement of discrepancies between left and right true hinge axis points. The results obtained as follows. 1. The mean distance from the arbitrary hinge axis point to the true hinge axis point was as follows. Right: horizontal distance; 1.99mm, vertical distance; 2.12mm, linear distance; 3.36 mm. Left: horizontal distance; 1.39mm, vertical distance; 2.06mm, linear distance; 2.09mm. Total: horizontal distance; 1.69mm, vertical distance; 2.09mm linear distance; 3.06 mm. 2. The 87.5% of true hinge axis points were within 5mm of the arbitrary hinge axis point. 3. The mean discrepancies between the right and left hinge axis point were 2.92mm in superoinferior direction and 4.74mm in anteroposterior direction. 4. When transferring the axis to the articulator, anatomic asymmetry between right: and left axis point produces in dislocation of cast on the articulator, and undesirable shift in esthetic tooth position will be resulted.

  • PDF

A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device

  • Liya Ma;Fei Liu;Jiansong Mei;Jiarui Chao;Zhenyu Wang;Jiefei Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2023
  • PURPOSE. To compare the sagittal condylar inclination (SCI) in dentate individuals measured by the different methods with mechanical articulator (MA), virtual articulator (VA), and a jaw tracking device (JTD) system. MATERIALS AND METHODS. A total of 22 healthy dentate participants were enrolled in this study. For MA workflow, the SCI was obtained by a semi-adjustable articulator with protrusive interocclusal records. The SCI was also set on a VA by aligning intraoral scan (IOS) with cone beam computed tomography (CBCT) and facial scan (FS), respectively. These virtual workflows were conducted in a dental design software, namely VAIOS-CBCT and VAIOS-FS. Meanwhile, a JTD system was also utilized to perform the measurement. Intraclass correlation was used to assess the repeatability within workflows. The bilateral SCI values were compared by Wilcoxon matched-pairs signed rank test for each workflow, and Kruskal-Wallis test and post hoc p-value Bonferroni correction were used to compare the differences among four workflows. The agreement of VAIOS-CBCT, VAIOS-FS, and JTD compared with MA was evaluated by Bland-Altman analysis. RESULTS. Intraclass correlation of the SCI revealed a high degree of repeatability for each workflow. There were no significant differences between the left and right sides (P > .05), except for VAIOS-CBCT (P = .028). Significant differences were not found between MA and VAIOS-FS (P > .05). Bland-Altman plots indicated VAIOS-CBCT, VAIOS-FS, and JTD were considered to substitute MA with high 95% limits of agreement. CONCLUSION. The workflow of VAIOS-FS provided an alternative approach to measure the SCI compared with MA.

The Study on the improvement of dental technician practical examination I (치과기공사 실기시험 개선에 관한 조사 연구 I)

  • Bae, Eun-Jeong;Kim, Woong-Chul;Chung, In-Sung;Nam, Sang-Yong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.413-421
    • /
    • 2012
  • Purpose: The purpose of this study is to investigate the improvement measure of dental technician practical examination. Methods: A survey was performed on 111 dental technicians who were self-written questionnaire. The results were analyzed by SPSS 12.0. The collected data was analyzed by frequency and chi-square test. Results: Questions most necessary work tools with the articulator was the highest with 55.9%, Electric wax carver(16.2%), heating clear(14.4%), CAD/CAM program(9.0%) was in the order. The need for additional practical test in response to actions included maxillary and mandibular comments occlusal work that you have to wax up the highest rate of 63.8%. Items most in need of improvement was strengthen of clinically oriented(48.0%), separation of written and practical(14.6%), control the degree of difficulty(11.4%) were the next order. Conclusion: Based on the results of this study, the current dental technician did not show major problems in the practical test. However, clinicians should be strengthened mainly. To do this, the use of the articulator is essential.