• Title/Summary/Keyword: underground depth

Search Result 657, Processing Time 0.029 seconds

Groundwater Flow Analysis for a Block Cavern Type Radwaste Repository (방사성폐기물 동굴처분 안전성 평가를 위한 지하수 유동 평가)

  • 황용수;서은진;강철형
    • Tunnel and Underground Space
    • /
    • v.14 no.3
    • /
    • pp.203-214
    • /
    • 2004
  • For total system performance of a potential radwaste repository, a hypothetical site is assumed with feasible boundary conditions. Assuming a coastal repository, the sensitivity of the depth and the location of a repository along with the distance to a joint on groundwater transport pathways is studied. Results from Connectflow analysis could be used as input of the MASCOT-t the probabilistic safety assessment code.

Preliminary results of groundwater flow simulation for high level radioactive disposal in Yu-seong area

  • Park kyung-woo;Cho sung-il;Kim chun-soo;Kim kyung-su;Lee kang-keun
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.253-257
    • /
    • 2005
  • This research aims to demonstrate the regional and site scale groundwater flow simulation for the high level radioactive disposal research site in Yu-seong. We used the Modflow by a finite difference method for groundwater flow simulation, and Modpath module in Modflow package for particle tracking simulation. The range of numerical domain for regional groundwater flow model is $16.32km{\times}20.16km$. And, the depth of numerical domain was expanded to 6,000m. The area of numerical domain for the site scale groundwater flow simulation is $1.6km{\times}1.6km$. Since 2005, the underground research tunnel(URT) is being constructed at KAERI(Korea Atomic Energy Research Institute) site. In the site scale groundwater flow model, the groundwater flow around the KAERI site is simulated. And the change of groundwater level with tunnel excavation is also predicted.

  • PDF

Assessment of Sinkhole Occurrences Using Fuzzy Reasoning Techniques

  • Deb D.;Choi S.O.
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2004.10a
    • /
    • pp.171-180
    • /
    • 2004
  • Underground mining causes surface subsidence long after the mining operation had been ceased. Surface subsidence can be in the form of saucer-shaped depression or collapsed chimneys or sinkholes. Sinkhole formations are predominant over shallow-depth room and pillar mines having weak overburden strata. In this study, occurrences of sinkholes due to mining activity are assessed based on local geological conditions and mining parameters using fuzzy reasoning techniques. All input and output parameters are represented with linguistic hedges. Numerous fuzzy rules are developed to relate sinkhole occurrences with input parameters using fuzzy relational matrix. Based on the combined fuzzy rules, possibility of sinkhole occurrences can be ascertained once the geological and mining parameters of any area are known.

  • PDF

Estimation of Preceding Displacement at Tunnel Excavation by NATM (NATM 시공에 의한 터널 굴착시 선행변위 추정에 관한 연구)

  • 신동오;임한욱;김치환
    • Tunnel and Underground Space
    • /
    • v.8 no.2
    • /
    • pp.87-95
    • /
    • 1998
  • Field instrumentation and numerical analysis by the finite difference method were applied to estimate the relaxed zone in a subway tunnel of shallow depth in soft rock, excavated by NATM. The convergence and ground displacement can be used to estimate the deformation behavior and the relaxed zone. Parameters for the several models previously suggested were measured using regression analysis techniques adopting a function of time and the face advance. The estimated relaxed zone by the MPBX and FDM analysis were 1.5~3.0 m and 1.5~2.0 m, respectively. It was concluded that the visco-elastic model and the time-dependent elasto-plastic model correlate very well ($r^2$>0.9) with results of the numerical analyses.

  • PDF

The Study on the Prediction and Measurement for the Behaviour of Structures and Weathered Soil & Rock in Excavating the Ventilation Shaft (지하철 개착구 굴착시 주변자반과 구조물에 대한 거동예측과 실측의비교평가)

  • 김융태;안대영;김득기;한창헌
    • Tunnel and Underground Space
    • /
    • v.4 no.1
    • /
    • pp.63-76
    • /
    • 1994
  • This paper discusses contents of the existing design, the behaviours prediction on the strut and retaining wall around subsurfaces, and also evaluates the measured results in comparison with the management criterion during excavation period of ventilation shaft at Pusan-Subway 220. Field measurements showed that maximum displacement 23.74 mm at boundary site of multistratification and the weathered rock to be formed at 0.2~0.6 H of total excavating depth(H), 68 ton of maximum axial force and 4.4X102 kg/cm2 of stress on strut. The measured axial force exceeds prediction levels by up to 50 percent at the weathered soil & rock, and the others come under the category of their levels. The great gap of both field measurements and prediction on behaviour makes a difference of the site situation at the design stage and the practical working. This measured value is greatly safety in comparison with that of the safety criterion, but axial force at 4~5 strut of ventilation shaft l is higher than the prediction.

  • PDF

Evaluation on the Performance of Design Parameters in Earth Tube System (지중튜브시스템 주요 설계 변수의 성능 평가)

  • Hwang, Yong-Ho;Hwang, Seok-Ho;Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.87-94
    • /
    • 2016
  • Earth tube system can be installed in many ways. However, performance data on earth tube system is still insufficient. Therefore, in this study seven design parameters of earth tube systems were chosen such as underground earth tube length, depth, tube thermal conductivity, thickness, radius, soil conditions, and fan type. And the change effects in the values of the seven parameters on earth tube exit temperatures and heat transfer rate were examined through Energyplus simulations.

A Study on the description of Horizontal Geothermal Heat pump Type on Small Residential House (소규모 주택에 대한 수평형 지열 히트펌프 형태 결정에 관한 연구)

  • Yun, Jang-Ryeol;Cho, Sung-Woo;Choi, Jung-Min
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.328-332
    • /
    • 2011
  • The conclusion is derived from the arranged results and using a simulation by determining the shape of an optimum heat pump which is appropriate for small scale houses. It is concluded as 3 meters long for the laying depth of underground piping of the horizontal type geothermal heat pump system in regard to the 5 RT capacity standard that is suitable for a small scale house. The shape of the horizontal type geothermal heat pump system for a small scale house is theThree pipe shape whose trench length is short and pipe length laid in a trench is short. It is 9 for the number of laying pipes that is most appropriate to system.

  • PDF

Evaluation of Numerical Experiment of Pollution Dispersion on the Sewer Crack Occurrence (하수관거 균열발생에 따른 오염확산의 수치실험 평가)

  • Park, Jaesung;Bae, Wooseok;Lee, Hojin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • Because sewer is embedded in land, the pollutant permeating to underground so fast can cause contamination of soil when crack of sewer occurs. In this study, numerical modelling on dispersion of pollutant at sewer crack was performed. Based upon the study, the following conclusions were obtained. It was shown that transfer direction of pollutant was similar to the flow with topography slope of surface. It was exposed that the pollutant permeated to 8~10m depth. It is expected to offer efficiency in sewer management in the future through this research.

  • PDF

Experimental Study on the Behavior of Psudo Circular Concrete Column (원형기둥 콘크리트 구멍손실 단면적의 압축거동에 관한 축소모델 실험적 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.89-98
    • /
    • 2001
  • There have been a lot of studies about repair & strengthening of the concrete structure. But there has almost not been my study on section damage effect due to holes drilled out for installing additional facilities or equipment, such as rack on the wall of building or underground culvert system, plumbing system through the column or wall of it, after being occupied. This study is to find out how much the section loss due to holes will give loss of section strength. We cm determine if we repair or reinforce it completely or not, using strength loss from the hole. Hole size of diameter 3cm, 2cm, lcm, depth of 3cm, 5cm, 10cm, and position of each hole has been considered as variables of this study. It is concluded that section loss 30% results in 53% of strength damage.

  • PDF

A Study of seismic analysis method of urban rail transit's underground concrete structure (도시철도 지중 콘크리트 구조물의 내진해석법 적용에 관한 연구)

  • Lee, Hee-Young;Lee, Dong-Ho;Kim, Eun-Kyum
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1159-1164
    • /
    • 2005
  • Seismic analysis methods in use on ground structure are equivalentstatic analysis, response-displacement method and dynamic analysis etc. Equivalentstatic analysis does not considerdynamic effect, and dynamic analysis process is very complex. then 'Urbanrail transit earthquake-resistance design standard (2005.06)' is persuading that analyze by response displacement method that consider enough dynamic effect of ground structure statically. But, It is very complex and difficult to apply response-displacement method in the field. So, modified equivalentstatic analysis or pseudo static analysis that is easy to apply in the field and have rationality of design is practically used. In this study, I try to prescribe the applicable scale of structure and static analysis that have calculative effectiveness about response-displacement method by comparing and analyzing the result of each analysis method according to the scale of urban rail transit' box type concrete structure and by performing seismic analysis that apply modified equivalentstatic analysis, pseudo static analysis and response-displacement method changing the kind of ground, depth of bedrock, size of structure.

  • PDF