A Study on the description of Horizontal Geothermal Heat pump Type on Small Residential House
소규모 주택에 대한 수평형 지열 히트펌프 형태 결정에 관한 연구
- Yun, Jang-Ryeol (Dept. of Green Energy Graduate School, Changwon National University) ;
- Cho, Sung-Woo (Dept. of Architectural Eng., Changwon National University) ;
- Choi, Jung-Min (Dept. of Architectural Eng., Changwon National University)
- Published : 2011.11.24
Abstract
The conclusion is derived from the arranged results and using a simulation by determining the shape of an optimum heat pump which is appropriate for small scale houses. It is concluded as 3 meters long for the laying depth of underground piping of the horizontal type geothermal heat pump system in regard to the 5 RT capacity standard that is suitable for a small scale house. The shape of the horizontal type geothermal heat pump system for a small scale house is theThree pipe shape whose trench length is short and pipe length laid in a trench is short. It is 9 for the number of laying pipes that is most appropriate to system.