The Study on the Prediction and Measurement for the Behaviour of Structures and Weathered Soil & Rock in Excavating the Ventilation Shaft

지하철 개착구 굴착시 주변자반과 구조물에 대한 거동예측과 실측의비교평가

  • 김융태 ((주) 벽산엔지니어링 플랜트사업본부 이사) ;
  • 안대영 ((주)벽산엔지니어링 플랜트사업본부이사) ;
  • 김득기 ((주)벽산엔지니어링 특수사업부 계장) ;
  • 한창헌 ((주)벽산엔지니어링 특수사업부 계장)
  • Published : 1994.04.01

Abstract

This paper discusses contents of the existing design, the behaviours prediction on the strut and retaining wall around subsurfaces, and also evaluates the measured results in comparison with the management criterion during excavation period of ventilation shaft at Pusan-Subway 220. Field measurements showed that maximum displacement 23.74 mm at boundary site of multistratification and the weathered rock to be formed at 0.2~0.6 H of total excavating depth(H), 68 ton of maximum axial force and 4.4X102 kg/cm2 of stress on strut. The measured axial force exceeds prediction levels by up to 50 percent at the weathered soil & rock, and the others come under the category of their levels. The great gap of both field measurements and prediction on behaviour makes a difference of the site situation at the design stage and the practical working. This measured value is greatly safety in comparison with that of the safety criterion, but axial force at 4~5 strut of ventilation shaft l is higher than the prediction.

Keywords