• Title/Summary/Keyword: ultimate soil resistance

Search Result 73, Processing Time 0.022 seconds

An Comparative Study on the Method of Determining Allowable Horizontal Bearing Capacity of Piles (말뚝의 허용횡방향지지력 결정법의 비교연구)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.267-274
    • /
    • 2021
  • Among several methods for determining the allowable lateral resistances of piles, the subgrade reaction method and ultimate lateral resistance method are generally used. To determine the effects of the soil conditions, pile head restraint conditions, and pile lengths on determining the allowable lateral resistances of piles, computations of the allowable lateral resistances of piles using the two methods were executed, and the computation results were compared. For piles in soft cohesive soil, the pile design is governed by the allowable lateral resistance of a pile from subgrade soil reaction method regardless of the pile head restraints conditions and pile lengths. The allowable lateral resistance of a pile from the ultimate lateral resistance governs the design as the undrained shear strength increases. Except for the case of a short pile, which is installed in loose granular soil, the allowable lateral resistance of a pile from ultimate lateral resistance governs the design of laterally loaded piles. According to this study, computation of the ultimate lateral resistance of a pile is needed, even though some opinions suggest that the design of a laterally loaded pile is satisfied only by the subgrade reaction method. The pile width barely influences the coefficient of horizontal subgrade reaction. Realistically, the effect of the pile width can be disregarded in the condition of common pile widths of 20~90cm.

Estimation of Ultimate Lateral Resistances of Piles Using CPT Cone Resistance in Sand (사질토지반에서 콘관입저항치 $q_c$에 의한 단말뚝의 극한수평단위지지력 평가)

  • Kim, Min-Kee;Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.71-77
    • /
    • 2008
  • In this study, CPT-based methodology for estimating the ultimate lateral resistance, $p_u$, is proposed and verified for lateral loaded piles in sandy soil. Preexistent methods estimating the ultimate lateral resistance, $p_u$, and the ultimate lateral capacity, $H_u$, of pile have been based on the vertical effective stress, relative density, and the coefficient of lateral earth pressure. Similarly, cone resistance $q_c$ in pure sandy soil is expressed by those essential factors. As correlation between $p_u$ and $q_c$ are normalized with average effective stress ${\sigma}_m$, estimation methodology for the lateral loaded pile of $p_u$ in sandy soil is proposed. The method is verified by calibration chamber test results in pure sand. The standard derivation of estimated $p_u$ is 0.279, and COV (Coefficient Of Variation) of estimated $p_u$ is 0.272. These results showed that the estimated pus by the method are analogous with the measured $p_us$ in calibration chamber test.

Ultimate Pullout Capacity of Underreamed Anchors Using Electric Discharge in weathered soil (풍화토지반에서 전기방전에 의한 확공앵커의 극한 인발력)

  • Kim, Sung-Kyu;Kim, Nak-Kyung;Kim, Jae-Won;Kang, Byung-Chul;Kim, Tae-Hun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1354-1359
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The anchor is an underreamed anchor by using high voltage electric discharge energy. In this study, a series of field test were carried out in order to find ultimate load of underreamed anchors in weathered soil at the new apartment construction site located in Inchon, Korea. Data were analyzed in order to define a relation between ultimate load and the number of electric discharge.

  • PDF

Nonlinear Analysis for the Prediction of Lateral Behavior of Single Piles in Non-homogeneous Sandy Soil (비균질 사질토 지반에서 단일말뚝의 수평거동 예측을 위한 비선형 해석기법)

  • 김영수;김병탁;허노영
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.5-16
    • /
    • 2000
  • THe purpose of this paper is to suggest the analytical method which can predict lateral nonlinear behavior in non-homogeneous soil using the coefficient of soil resistance and ultimate soil resistance. Those parameters are obtained through back analysis on the base of the results of a series of model tests.Analytical method of Chang is more or less difficult to predict nonlinear behavior in non-homogeneous sol. So, in this study, for the prediction of nonlinear behavior the compositive analytical method which apply the p - y curve to Chang model is suggested. Also, the program is developed to predict nonlinear behavior using the compositive analytical method and it can be used to calculated the deflection, bending moment and soil reaction with DFM in non-homogeneous soil. To establish applicability of the suggested analytical method, the results of model tests and field tests and Pentagon2D finite element program are compared with those of the compositive analytical method. In the analysis values of the coefficient of soil reaction and ultimate soil resistance are also applied to the case of non-homogeneous soil. Lateral defection calculated using the compositive analytical method has been found to be in good agreement with values measured in field and model load tests.

  • PDF

A Study on the Uplift Capacity of Cylindrical Concrete Foundations for Pipe-Framed Greenhouse (파이프 골조온실의 원주형 콘크리트 기초의 인발저항력에 관한 연구)

  • ;;;;Shino Kazuo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.4
    • /
    • pp.109-119
    • /
    • 1998
  • Recently pipe-framed greenhouses are widely constructed on domestic farm area. These greenhouses are extremely light-weighted structures and so are easily damaged under strong wind due to the lack of uplift resistance of foundation piles. This experiment was carried out by laboratory soil tank to investigate the displacement be haviors of cylindrical pile foundations according to the uplift loads. Tested soils were sampled from two different greenhouse areas. The treatment for each soil type are consisted of 3 different soil moisture conditions, 2 different soil depths, and 3 different soil compaction ratios. Each test was designed to be repeated 2 times and additional tests were carried out when needed. The results are summarized as follows : 1. When the soil moisture content are low and/or pile foundations are buried relatively shallow, ultimate uplift capacity of foundation soil was generated just after begining of uplift displacement. But under the high moisture conditions and/or deeply buried depth, ultimate up-lift capacity of foundation soil was generated before the begining of uplift displacement. 2. For the case of soil S$_1$, the ultimate uplift capacity of piles depending on moisture contents was found to be highest in optimum moisture condition and in the order of air dryed and saturated moisture contents. But for the case of soil S$_2$, the ultimate uplift capacity was found to be highest in optimum moisture condition and in the order of saturated and air dryed moisture contents. 3. Ultimate uplift capacities are varied depending on the pile foundation soil moisture conditions. Under the conditions of optimum soil moisture contents with 60cm soil depth, the ultimate uplift capacity of pile foundation in compaction ratio of 80%, 85%, and 90% for soil 51 are 76kg, 115kg, and 155kg, respectively, and for soil S$_2$are 36kg, 60kg, and 92kg, respectively. But considering that typical greenhouse uplift failure be occurred under saturnted soil moisture content which prevails during high wind storm accompanying heavy rain, pile foundation is required to be designed under the soil condition of saturated moisture content. 4. Approximated safe wind velosities estimated for soil sample S$_1$and S$_2$are 32.92m/s and 26.58m/s respectively under the optimum soil condition of 90% compaction ratio and optimum moisture content. But considering the uplift failure pattern under saturated moisture contents which are typical situations of high wind accompanying heavy rain, the safe wind velosities for soil sample S$_1$and S$_2$are not any higher than 20.33m/s and 22.69m/s respectively.

  • PDF

Evaluation of the Resistance Bias Factors to Develop LRFD for Gravel Compaction Piles (LRFD 설계를 위한 쇄석다짐말뚝공법의 저항편향계수 산정)

  • Han, Yong-Bae;Park, Joon-Mo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.43-55
    • /
    • 2012
  • In this study, the resistance bias factors are calculated to determine the resistance factor of Gravel Compaction Piles which is one of the soft ground improvement methods. In order to calculate resistance bias factors for gravel compaction piles, two ultimate bearing capacities were analyzed. One is the ultimate bearing capacity in 2.54 cm settlement measured using data of the field loading test on 41 piles and the other is the ultimate bearing capacity calculated using the seven equations concerning bulging failure. The results of analysis show that the probability density function of the calculated ultimate bearing capacities has a lognormal distribution. Resistance bias factor and the coefficient of variation for Greenwood equation are 0.91 and 0.38, respectively, and for those of Hughes & Withers are 1.19 and 0.39. The two equations are suitable for calculating resistance factors for LRFD of soil improvement using gravel compaction piles.

An Analysis of Cone Penetration Based on Arbitrary Larangian-Eulerian Method (Arbitrary Lagrangian-Eulerian 기법에 의거한 콘 관입 해석)

  • Oh, Se-Boong
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.85-98
    • /
    • 2001
  • Cone penetration was analyzed by arbitrary Lagangian-Eulerian(ALE) method. In order to simulate full penetration, steady state analyses were performed using ABAQUS/Explicit, which models upward flow of soil layers. In the analysis of homogeneous layer it was found that the paths and the strain of soil particles were consistent with the result of the strain path method and that the ultimate resistance were reasonably evaluated. The cone penetration through different soil layers was also analyzed and that showed the transfer of cone resistance. The steady state ALE analysis could perform full penetration through the layered soils.

  • PDF

An Experimental Study on the Behavior of Miscopiles installed in Weathered Weak Rock (풍화암 지반에 설치된 소구경말뚝의 거동에 관한 연구)

  • 박성재;정경환;이세훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.389-396
    • /
    • 1999
  • In this study compressive and tensile load tests have been performed to investigate reinforcing effect and load transfer mechanism of small diameter piles installed in the foundation soil for the marine suspension bridge. Load tests were carried out on steel plate with diameters of 50cm, 100cm and 150cm varying loads starting from 39 tons up to 314 tons. Small diameter piles were proved to behavior like as friction piles and loads were not transmitted to the bottom of piles. From pull-out tests, the uplift capacity of small diameter piles was largely influenced by reinforcing materials compared to frictional resistance between piles and adjacent soils. The bearing capacity of small diameter piles appeared to be higher than the ultimate bearing capacity evaluated using static formulae. The load carrying capacity of small diameter piles was superior to the bored piles with a similar size. Thus, ultimate bearing capacity estimated from static formulae can provide conservative designs and thereby resulting in economic disadvantages. A further study to accumulate data regarding various soil conditions is recommended for an improved estimation of bearing capacity of piles with small diameter.

  • PDF

A Study on Behavior of Pull-out Loaded Suction Pile in Sands (사질토지반에서 인발하중을 받는 석션말뚝에 관한 연구)

  • Kim, Jin-Bok;Park, Joung-Un;Jin, Hong-Min;Kwon, Oh-Kyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.944-955
    • /
    • 2009
  • In this thesis the model tests were performed to the pull-out characteristics of a suction pile subjected to a pull-out in sands. For this model tests, three different soil conditions ($D_r$=45, 65, 82%), three pile diameters (D=100, 150, 200mm) and three pile lengths (L=100, 150, 200mm), were changed. And the experimental results were also compared with those by the theoretical methods. The results by the experimental and theoretical analysis are as follows. The ultimate pull-out resistances increased as the relative density of sands, pile diameter, length and the ratio of pile length to diameter increased. The ultimate pull-out resistance by Meyerhof method(1973) overestimated that by the model test, but the results using the soil-pile friction angle suggested by Aas(1966) in the Meyerhof(1973) method were in good agreement with the experimental results.

  • PDF

The Ultimate Bearing Capacity and Estimation Method of Rigid Pile for Port Structures under Lateral Load (횡하중이 작용하는 항만구조물에서 짧은말뚝의 극한지지력 및 평가방법)

  • Kim, Byung-Il;Han, Sang-Jae;Kim, Jong-Seok;Kim, Do-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.1
    • /
    • pp.75-91
    • /
    • 2014
  • In this study the analysis is performed for influencing factors on the behavior of rigid piles (short pile) by research papers and case study. The results indicated that the point of virtual fixity should be calculated considering the relative stiffness of soil and pile, and Chang (1937) and P-Y method estimated the similar fixity. The values of ultimate resistances of a vertical pile to a lateral load are different for laboratory and field tests in cohesive soils and its ultimate values in laboratory tests are underestimated and in field tests are under or overestimated. The estimated resistance by Hansen (1961)'s method is similar to the value of field tests. The horizontal resistances to laterally loaded pile in cohesionless soils are overestimated in laboratory tests and generally overestimated in field tests. The ultimate resistances by Zhang (2005)'s method, used to the empirical distribution of the resistance, are similar to the test results. In the paper the calculating method and distribution of the ultimate resistance in cohesive soils are proposed. The estimated value by the proposed method is closer to the test results than any other method of calculating ultimate resistance of the piles embedded into cohesive soils.