• Title/Summary/Keyword: type B

Search Result 9,652, Processing Time 0.034 seconds

Characterization and Enterotoxigenicity of Staphylococcus aureus Isolated form Patient and Healthy Human (환자 및 건강인 유래 Staphylococcus aureus의 특성과 Enterotoxin 산생성)

  • 최홍근;손원근;강호조
    • Journal of Food Hygiene and Safety
    • /
    • v.6 no.2
    • /
    • pp.89-93
    • /
    • 1991
  • The present study was conducted to investigate the prevalence, the biochemical properties and the enterotoxin types of Staphylococcus aureus in healthy human and patient. A total of 61 S. aureus strains were isolated from 142 samples. The prevalence of S. aureus isolated from healthy human and patient were 17.7% and 14.0%, respectively. All the isolates showed the production of coagulase, lecithinase and hemolysis (${\alpha}-hemolysis;\;32.8%,\;{\beta}-hemolysis;\;67.2%$) on sheep blood agar. Coagulase type VII (38.4%) and type 111 (26.0%) were dominant among coagulase types I through VIII. Twenty-four (52.2%) of 46 strains tested produced one or more enterotoxin; enterotoxin A, Band C were produced by 3, 9 and 12 strains, respectively. Enterotoxins were produced by 100% of type 11 strains, 75% of type 111 and 39.1 % of type VII. Commonly, coagulase type II produced enterotoxin B or C, and type VII produce enterotoxin C.

  • PDF

ON THE OSTROWSKI INEQUALITY FOR THE RIEMANN-STIELTJES INTEGRAL ${\int}_a^b$ f (t) du (t), WHERE f IS OF HÖLDER TYPE AND u IS OF BOUNDED VARIATION AND APPLICATIONS

  • DRAGOMIR, S.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.5 no.1
    • /
    • pp.35-45
    • /
    • 2001
  • In this paper we point out an Ostrowski type inequality for the Riemann-Stieltjes integral ${\int}_a^b$ f (t) du (t), where f is of p-H-$H{\ddot{o}}lder$ type on [a,b], and u is of bounded variation on [a,b]. Applications for the approximation problem of the Riemann-Stieltjes integral in terms of Riemann-Stieltjes sums are also given.

  • PDF

GENERALIZED COMPOSITION OPERATORS FROM GENERALIZED WEIGHTED BERGMAN SPACES TO BLOCH TYPE SPACES

  • Zhu, Xiangling
    • Journal of the Korean Mathematical Society
    • /
    • v.46 no.6
    • /
    • pp.1219-1232
    • /
    • 2009
  • Let H(B) denote the space of all holomorphic functions on the unit ball B of $\mathbb{C}^n$. Let $\varphi$ = (${\varphi}_1,{\ldots}{\varphi}_n$) be a holomorphic self-map of B and $g{\in}2$(B) with g(0) = 0. In this paper we study the boundedness and compactness of the generalized composition operator $C_{\varphi}^gf(z)=\int_{0}^{1}{\mathfrak{R}}f(\varphi(tz))g(tz){\frac{dt}{t}}$ from generalized weighted Bergman spaces into Bloch type spaces.

INTEGRAL REPRESENTATION OF SOME BLOCH TYPE FUNCTIONS IN ℂn

  • Choi, Ki Seong;Yang, Gye Tak
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1997
  • Let B be the open unit ball in the complex space $\mathbb{C}^n$. A holomorphic function $f:B{\rightarrow}C$ which satisfies sup{(1- ${\parallel}\;{\nabla}_zf\;{\parallel}\;{\mid}z{\in}B$} < $+{\infty}$ is called Bloch type function. In this paper, we will find some integral representation of Bloch type functions.

  • PDF

SPECTRAL DECOMPOSITION OF k-TYPE NONWANDERING SETS FOR ℤ2-ACTIONS

  • Kim, Daejung;Lee, Seunghee
    • Bulletin of the Korean Mathematical Society
    • /
    • v.51 no.2
    • /
    • pp.387-400
    • /
    • 2014
  • We prove that the set of k-type nonwandering points of a Z2-action T can be decomposed into a disjoint union of closed and T-invariant sets $B_1,{\ldots},B_l$ such that $T|B_i$ is topologically k-type transitive for each $i=1,2,{\ldots},l$, if T is expansive and has the shadowing property.

ON BARYCENTRIC TRANSFORMATIONS OF FANO POLYTOPES

  • Hwang, DongSeon;Kim, Yeonsu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.5
    • /
    • pp.1247-1260
    • /
    • 2021
  • We introduce the notion of barycentric transformation of Fano polytopes, from which we can assign a certain type to each Fano polytope. The type can be viewed as a measure of the extent to which the given Fano polytope is close to be Kähler-Einstein. In particular, we expect that every Kähler-Einstein Fano polytope is of type B. We verify this expectation for some low dimensional cases. We emphasize that for a Fano polytope X of dimension 1, 3 or 5, X is Kähler-Einstein if and only if it is of type B.

GEOMETRY OF GENERALIZED BERGER-TYPE DEFORMED METRIC ON B-MANIFOLD

  • Abderrahim Zagane
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.4
    • /
    • pp.1281-1298
    • /
    • 2023
  • Let (M2m, 𝜑, g) be a B-manifold. In this paper, we introduce a new class of metric on (M2m, 𝜑, g), obtained by a non-conformal deformation of the metric g, called a generalized Berger-type deformed metric. First we investigate the Levi-Civita connection of this metric. Secondly we characterize the Riemannian curvature, the sectional curvature and the scalar curvature. Finally, we study the proper biharmonicity of the identity map and of a curve on M with respect to a generalized Berger-type deformed metric.

Comparative Study on the Subsurface Drainage Discharge Performance by the Type of Non-Excavation Subsurface Drainage Culvert (비굴착 지하배수암거 형태별 지하배수 성능 비교분석)

  • Kim, Hyuntai;Ryu, Jeonyong;Jung, Kiyuol;Seo, Donguk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.73-81
    • /
    • 2018
  • In this study, subsurface discharge performance has been studied through theoretical seepage analysis on four types of culverts that can be installed under the condition of non-excavation, such as (a)perforated pipe(${\Phi}50mm$), (b)perforated pipe+horizontal mat (B50cm) (c)perforated pipe+horizontal mat+vertical gravel(B<10cm), (d)perforated pipe+vertical gravel(B<10cm), and existing typical type (e)perforated pipe with gravel (B40, h=40cm) which can be installed by excavation. The analysis results were as follows. i) Subsurface discharge performance per unit (m) was (a)type 56%, (b) 91%, (c) 96%, (d) 76%, respectively, lower than the value of (e)culvert. ii) However, considering that non-excavation culvert can be installed at a spacing of 5m with the installation cost of the existing excavation culvert at the interval of 10m, it was analyzed that unit subsurface discharge(q) of (a)20.2mm/day(110%), (b)32.8(178%), (c)34.6(188%) (d)27.5(149%) in the four types of non-excavation culvert installed at intervals of 5m under the condition of $ k=10^{-4}cm/s$ was much larger than the amount of (e)type 18.5(100%), existing excavation culvert installed at 10m interval. iii) Through the test construction, peak subsurface drainage discharge($q_p$) was 38.4mm/day, which is larger than the value of design criteria and confirmed that it satisfies the analysis results as well. iv) In particular, it was evaluated that (b)perforated pipe+horizontal mat(B50cm) are low cost, high efficiency subsurface drainage culvert type with sufficient drainage performance(178%).

A Study on the Evaluation of the Daylighting Performance in the Sound Barrier Tunnel (축소모형을 이용한 방음터널의 자연채광 성능평가에 관한 연구)

  • Kim, Oim-Gon;Choi, Jeong-Min;Park, Chang-Seob;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • This study aims to evaluate the natural lighting performance in the sound barrier tunnel. Therefore, to evaluate the daylighting performance, the combinations of 3 tunnel roof types which are flat-roof-type(type A), slope-roof-type(type B), arch-roof-type(type C) and 3 window types which are side-window-type(type 1), one-window-roof type(type 2), two-window-roof type(type 3) are evaluated by experimenting small scaled models. In this 9 cases of experiment, illuminance levels of each case are analyzed and evaluated. The conclusion of this study is that slope-roof-type(B) and arch-roof-type(C) is preferable to flat-roof-type(A) and one-window-roof-type(B) and two-window-roof-type(C) is preferable to side-window-type(A) for daylighting in the sound barrier tunnel.

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.