• Title/Summary/Keyword: two-level system

Search Result 3,885, Processing Time 0.044 seconds

Cyclic testing of innovative two-level control system: Knee brace & vertical link in series in chevron braced steel frames

  • Rousta, Ali Mohammad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.301-310
    • /
    • 2017
  • For further development of passive control systems to dissipate larger seismic energy and prevent the structures from earthquake losses, this paper proposes an innovative two-level control system to improve behavior of chevron braced steel frames. Combining two Knee Braces, KB, and a Vertical Link Beam, VLB, in a chevron braced frame, this system can reliably sustain main shock and aftershocks in steel structures. The performance of this two-level system is examined through a finite element analysis and quasi-static cyclic loading test. The cyclic performances of VLB and KBs alone in chevron braced frames are compared with that of the presented two-level control system. The results show appropriate performance of the proposed system in terms of ductility and energy dissipation in two different excitation levels. The maximum load capacity of the presented system is about 30% and 17% higher than those of the chevron braced frames with KB and VLB alone, respectively. In addition, the maximum energy dissipation of the proposed system is about 78% and 150% higher than those of chevron braced frames with VLB and KB respectively under two separate levels of lateral forces caused by different probable seismic excitations. Finally, high performance under different earthquake levels with competitive cost and quick installation work for the control system can be found as main advantages of the presented system.

Two Level-Parallel Type Inventory Systems with Backorder and Redistribution (사후주문과 재분배를 고려한 2수준 재고시스템)

  • 권희철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.17 no.32
    • /
    • pp.113-120
    • /
    • 1994
  • This study presents a two level-parallel type inventory systems with one upper level facility in the first echelon and n-lower level facilities in the second echelon. The stocks at the lowest facilities can become unbalanced with the random variations in the demands. This paper deals with the imbalance by considering redistribution and backorder. The system with redistribution and the system with backorder and redistribution are analized. The comparison of two cases shows that the system with redistribution and backorder gives smaller stocks than the system with redistribution.

  • PDF

A TWO-LEVEL FINITE ELEMENT METHOD FOR THE STEADY-STATE NAVIER-STOKES/DARCY MODEL

  • Fang, Jilin;Huang, Pengzhan;Qin, Yi
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.4
    • /
    • pp.915-933
    • /
    • 2020
  • A two-level finite element method based on the Newton iterative method is proposed for solving the Navier-Stokes/Darcy model. The algorithm solves a nonlinear system on a coarse mesh H and two linearized problems of different loads on a fine mesh h = O(H4-𝜖). Compared with the common two-grid finite element methods for the considered problem, the presented two-level method allows for larger scaling between the coarse and fine meshes. Moreover, we prove the stability and convergence of the considered two-level method. Finally, we provide numerical experiment to exhibit the effectiveness of the presented method.

Two-level control system of toggle braces having pipe damper and rotational friction damper

  • Ata Abdollahpour;Seyed Mehdi Zahrai
    • Structural Engineering and Mechanics
    • /
    • v.86 no.6
    • /
    • pp.739-750
    • /
    • 2023
  • This study examines the two-level behavior of the toggle brace damper within a steel frame having a yielding pipe damper and rotational friction damper. The proposed system has two kinds of fuse for energy dissipation in two stages. In this mechanism, rotational friction damper rather than hinged connection is used in toggle brace system, connected to a pipe damper with a limited gap. In order to create a gap, bolted connection with the slotted hole is used, such that first a specific movement of the rotational friction damper solely is engaged but with an increase in movement, the yielding damper is also involved. The performance of the system is such that at the beginning of loading the rotational friction damper, as the first fuse, absorbs energy and with increasing the input load and further movement of the frame, yielding damper as the second fuse, along with rotational friction damper would dissipate the input energy. The models created by ABAQUS are subjected to cyclic and seismic loading. Considering the results obtained, the flexibility of the hybrid two-level system is more comparable to the conventional toggle brace damper. Moreover, this system sustains longer lateral displacements. The energy dissipation of these two systems is modeled in multi-story frames in SAP2000 software and their performance is analyzed using time-history analysis. According to the results, permanent relocations of the roof in the two-level system, in comparison with toggle brace damper system in 2, 5, and 8-story building frames, in average, decrease by 15, 55, and 37% respectively. This amount in a 5-story building frame under the earthquakes with one-third scale decreases by 64%.

Construction of the reduced system by two-level scheme and time integration in the reduced system under arbitrary loading (2단계 축소기법에 의한 축소시스템의 구성과 동하중에 의한 구조물의 동적 거동에 관한 연구)

  • Kim, Hyun-Gi;Cho, Maeng-Hyo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.453-458
    • /
    • 2004
  • This study proposes a new two-level condensation scheme for the construction of a reduced system. In the first step, the candidate area is selected for the construction of the reduced system by energy estimation in element-level. In the second step, primary degrees of freedom are selected by sequential elimination from the candidate degrees of freedom linked to the selected elements. Numerical examples demonstrate that the proposed method saves the computational cost effectively and provides a reduced system which predicts the eigenvalues accurately. Moreover, the well-constructed reduced system can present the reliable behavior of the structure under arbitrary dynamic loads comparing to that of global system. Time integration in a reduced system can save the computing time remarkably. Through a few numerical examples, the efficiency and reliability of the proposed scheme are verified.

  • PDF

A Two-Plan Sampling System for Life Testing Under Weibull Distribution

  • Aslam, Muhammad;Balamurali, Saminathan;Jun, Chi-Hyuck;Ahmad, Munir
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.1
    • /
    • pp.54-59
    • /
    • 2010
  • A two-plan sampling system is proposed for a failure-censored life testing when the lifetime follows a Weibull distribution with known shape parameter. The proposed sampling system is based on a switching rule, for switching between the tightened and the normal inspection levels when lots are submitted for inspection in the order of production or in some other systematic way. The design parameters of the proposed sampling system are determined by the two-point approach considering the producer's risks and the consumer's at the specified acceptable reliability level and the lot tolerance reliability level, respectively. It has been observed that the proposed system requires only a single failure for the observation.

Torque Ripple Minimization for Induction Motor Driven by a Photovoltaic Inverter

  • Atia, Yousry
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.679-690
    • /
    • 2009
  • The paper presents a new photovoltaic inverter for stand-alone induction motor application. The proposed system is composed of two stages. First stage is for the photovoltaic dc power feeding and second stage is dedicated to the motor-inverter subsystem and control technique. A direct torque control (DTC) with a novel switching strategy for motor torque ripple minimization is introduced. The novel DTC strategy is based on selecting a suitable voltage vector group for motor torque ripple minimization. A three-level voltage source inverter (VSI) is used instead of a two level inverter because the first has more available vectors and lower ripples in the output current and flux than the second, thus it has lower torque ripples. The photovoltaic array and battery bank are sized and the configuration is indicated based on sun-hour methodology. Simulation results show a comparison between three systems; two level VSI with conventional DTC strategy, three level VSI with conventional DTC, and the proposed system that has a novel DTC switching strategy applied to three level VSI. The results show that the proposed system has lower ripples in the current, flux and torque of the motor.

Two Level-Parallel Type Inventory Systems for Aggregate Backorders (총괄 사후주문을 고려한 2수준 병렬형 재고분배시스템)

  • 권희철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.13 no.21
    • /
    • pp.101-110
    • /
    • 1990
  • This study presents a two-level inventory distribution system with one-upper level facility(warehouse) in first echelon and n-lower level facilities(stores) in the second echelon. The demand process at the upper level is induced by the aggregated backorder processes of n independently operated lower level facilities in parallel. For the upper level and the lower level we find the decision points and the distribution function of the aggregate backorders from n-stores. Optimal allocation units and expected system profits are obtained. If the product is of great enough importance to the customer, echelon structure will include a shadow installation. Also, this case is analyzed. Numerical examples are presented to illustrate the results for each case.

  • PDF

Detection of the Popple Spot on the Pulse Variance of the Sonance

  • Kim, Jeong-lae;Kim, Hye-ju;Lee, Kee-young
    • International journal of advanced smart convergence
    • /
    • v.8 no.1
    • /
    • pp.106-112
    • /
    • 2019
  • Pulsation variance technique is blended the bumpy popple-sonance status of the brilliant-disparity understanding level (BDUL) on pulsation understanding gestalt. The understanding level condition by the pulsation understanding gestalt system is composed with the popple-sonance system. As to look for a two-node white-small dot of the brilliant situation, we are to take of the pulsation value with two-node white-small dot by the output signal. The concept of understanding level is composed the reference of brilliant-disparity level for variance signal by the pulsation sonance gestalt. Moreover indicating a bumpy variance of the BDUL of the maximum-minimum in terms of the popple-sonance gestalt, and pulsation two-node white-small dot sonance that was the a pulsation value of the far variance of the Pul-ug-FA-${\pi}_{MAX}$-MIN with $23.24{\pm}3.36units$, that was the a pulsation value of the convenient variance of the Pul-ug-CO-${\pi}_{MAX}$-MIN with $7.97{\pm}1.60units$, that was the a pulsation value of the flank variance of the Pul-ug-FL-${\pi}_{MAX}$-MIN with $3.02{\pm}0.47units$, that was the a pulsation value of the vicinage variance of the Pul-ug-VI-${\pi}_{MAX}$-MIN with $0.50{\pm}(-0.01)units$. The popple sonance will be to evaluate at the bumpy ability of the popple-sonance gestalt with two-node white-small dot by the pulsation understanding level on the BDUL that is indicated the brilliant-disparity gestalt by the understanding level system. We will be possible to suppress of a gestalt by the special signal and to utilize a pulsation data of popple sonance level by the popple understanding system.

A study on power control of nuclear reactor using revised two-level costate prediction method (개선된 two-level costate prediction method를 이용한 원자로 출력 제어)

  • 천희영;박귀태;이희정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.244-247
    • /
    • 1986
  • A revised two-level costate prediction algorithm is developed for the optimization of nonlinear nuclear power plant. The algorithm is proved to converge very well, and appears to require substantially small computation time and storage than previous nonlinear optimization algorithm. To cope with unknown external disturbances, we construct a closed loop control system. In order to get a smaller sampling time, this paper proposes the two-level Kalman filter.

  • PDF