• Title/Summary/Keyword: top-open space

Search Result 31, Processing Time 0.026 seconds

Field Tests and Analysis of Groundwater System for Stabilization of Slope in Large Open-Pit Coal Mine (대규모 노천 석탄광산의 사면 안정화를 위한 지하수 유동 체계 분석)

  • Ryu, D.W.;Kim, H.M.;Oh, J.H.;Sunwoo, C.;Jung, Y.B.
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.248-260
    • /
    • 2009
  • With regard to oversea mineral resources development, recent trend has been changed from a simple capital investment to a direct development of the resources. In relation to the stability of a slope in large open-pit coal mine, groundwater system was investigated and the validity of horizontal drainage hole was evaluated in Pasir coal mine, Indonesia. In this work, various field tests were carried out for a characterization of groundwater system, which included in-situ permeability measurement, tracer test and monitoring of groundwater levels. Especially, the influence of SM river on the characteristics of the groundwater flow system was mainly inspected. For the permeability measurement, Guelph permeameter was employed, and was found that sandstone was more permeable than mudstone and coal seam. From a comparison of lithological structure and the results of groundwater level monitoring, sandstone and thin coal seam with fractures were found to be a main channel for groundwater flow. In the results of tracer tests, the effect of SM river on the groundwater system depends on the geological structure of its base. To identify the effect of horizontal drainage holes, 2-D groundwater modeling was performed. Four different cases were tested, which are different from the length of drainage hole and the existence of pond on top of the slope. To enhance the drainage effect and slope stability, the drainage hole should be drilled to the depth of coal seam layer, which provides a main pathway of groundwater flow and embedded by sandstone. For this purpose, correct identification of surrounding geology should be preceded.

A Study on the Characteristics of Colors Used for Apartment Model Houses - Focused on Living Rooms of Medium Size Houses($100-165m^2$) Built in Metropolitan Area in the late 2000s - (아파트 모델하우스의 단위주호에 사용된 색채특성에 관한 연구 - 2000년대 후반 수도권 지역에 건설된 중규모($100-165m^2$) 단위주호 공간의 거실을 중심으로 -)

  • Choi, Jin-Hee;Jeong, Yoo-Na
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.244-253
    • /
    • 2011
  • Due to the development of modern society, desire for residence is not merely for the purpose of habitation. It's also used to represent the joy of living, the resident's emotional expressions, and social status. In order to express such desires, one of the most important factors used to portray them visually is the usage of color. When apartments are constructed, model houses are created to show potential tenants a sample house. The color scheme of those sample houses have been changed in accordance to the transition in the eras. Since 2000, construction companies have created their own apartment brand in order to create their own signature image. To achieve this signature image, one can alter the surface level and use other materials, and colors. I have researched the usage of colors out of the above. The criteria that need to be fulfilled to be a subject for my research are in the top 5 construction companies of the year 2010, within the metropolitan area, and open after 2009. As the result, all construction companies used colors Y and YR. An as accent colors on props such furniture and curtains, they used colors P, PB, and R. They were differences in color tones in each construction company and as the square footage increase, they used color contrasts. Hillstate and Raemian used darker shades in the larger houses. But the color tones YR and Y were used in all houses regardless of their size. E-world, Xi, and Prugio showed differences in shade and tone of colors regardless of size but rather depending on the locations of the apartments.

Fundamental Study of Energy Harvesting using Thermoelectric Module on Road Facilities (열전소자를 활용한 도로구조물에서의 에너지 하베스팅 기초 연구)

  • Lee, Jae-Jun;Kim, Dae-Hoon;Lee, Kang-Hwi;Lim, Jae-Kyu;Lee, Seung-Tae
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : An conventional method for electric power generation is converting thermal energy into mechanical energy then to electrical energy. Due to environmental issues such as global warming related with $CO_2$ emission etc., were the limiting factor for the energy resources which resulting in extensive research and novel technologies are required to generate electric power. Thermal energy harvesting using thermoelectric generator is one of energy harvesting technologies due to diverse advantages for new green technology. This paper presents a possibility of application of the thermoelectric generator's application in the direct exchange of waste solar energy into electrical power in road space. METHODS : To measure generated electric power of the thermoelectric generator, data logger was adopted as function of experimental factors such as using cooling sink, connection methods etc. Also, the thermoelectric generator、s behavior at low ambient temperature was investigated as measurement of output voltage vs. elapsed times. RESULTS : A few temperature difference between top an bottom of the thermoelectric generator is generated electric voltage. Components of an electrical circuit can be connected in various ways. The two simplest of these are called series and parallel and occur so open. Series shows slightly better performance in this study. An installation of cooling sink in the thermoelectric generator system was enhanced the output of power voltage. CONCLUSIONS : In this paper, a basic concepts of thermoelectric power generation is presented and applications of the thermoelectric generator to waste solar energy in road is estimated for green energy harvesting technology. The possibility of usage of thermoelectric technology for road facilities was found under the ambient thermal gradient between two surfaces of the thermoelectric module. An experiment results provide a testimony of the feasibility of the proposed environmental energy harvesting technology on the road facilities.

A Study on the Living Quarter interior design of Offshore Ship - Focused on the Living Qauter of FPSO - ("Offshore"해양특수선의 LQ실내디자인에 관한 연구 - FPSO선박의 Living Quarter를 중심으로 -)

  • Joo, Min-Kyoo;Lee, Gyoo-Baek
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.357-366
    • /
    • 2013
  • Global Energy Industry's high oil prices persist while their petroleum and gas production areas are entering the decline phase. More and more the drilling facilities used to bore oil from deeper depths are advancing further out into the oceans, which cause the development of "OFFSHORE" ship manufacturer facility's production demands to increase. The "OFFSHORE" ships provide a living space or L.Q (Living Quarters) for crewmen who work on the water far away from any mainland for extended periods of time. This research analyzes the LQ areas and the characterization of interior designs of different types of "OFFSHORE" ships that were built in South Korea. Also using overseas countries' Classification Society, known as "NORSOK," and analyzing their own design guidelines in conjunction with the research, the process of interior design and baseline data research was used to blueprint the new LQ areas. According to the results of the research, where ships get comprised of characteristics and operations by standards of the Classification Society's RULE, has the greatest effect on the design and design method of the LQ area. The research also shows that a conservative shipbuilding market of the Shipbuilding Company and ship owners' feelings are steadily changing to more open mindedness of acceptance. Therefore, the Korean Classification Society has to provide the new design principle to correspond to the international regulations and more various interior design plans of LQ areas needed to be present based on the new design guidelines. The capacity of the South Korean OFFSHORE shipbuilding industry is the world's top leader; however, the interior design of the LQ areas are still based from outdated designs from the 1980's. Hopefully these research results will be the cornerstone to help the shift from the outdated designs of the LQ areas to more practical modern designs.

Air Temperature Decreasing Effects by Shading and Ventilation at Micro-scale Experiment Plots (소공간 실험구의 차광과 통풍에 의한 기온저감 효과)

  • Kim, Hyun-Cheol;Woo, Ji-Keun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.6
    • /
    • pp.39-48
    • /
    • 2010
  • The purpose of this study was to analyze air temperature decreasing effects by shading and ventilation at micro-scale experiment plots, especially focused on the Wet Bulb Globe Temperature (WBGT) in outdoor spaces. To monitor the time-serial changes of Dry-bulb Temperature (DT), Globe Temperature (GT) and Relative Humidity (RH) in the wind blocking and shading conditions, Two hexahedral steel frames were established on the open grass field, the dimension of each frame was 1.5m(W)${\times}$1.5m(L)${\times}$1.5m(H). Four vertical side of one frame was covered by transparent polyethylene film to prevent wind passing through (Wind break plot; WP). The top side of the other frame was covered with shading curtain which intercept 95% of solar light and energy (Shading plot; SP). And, Another vertical steel frame without any treatment preventing ventilation and sunlight was set up, which represents natural conditions (Control plot; CP). The major findings were as follows; 1. The average globe temperature (GT) was highest at WP showing $50.94^{\circ}C$ and lowest at SP showing $34.58^{\circ}C$. The GT of natural condition (SP) was $42.31^{\circ}C$ locating the midst between WP and SP. The difference of GT of each plot was about $8-16^{\circ}C$, which means the ventilation and shading has significant effect on decreasing the temperature. 2. WP showed the highest average dry-bulb temperature (DT) of $38.41^{\circ}C$ which apparently differ from SP and CP showing $31.94^{\circ}C$ and $33.15^{\circ}C$ respectively. The DT of SP and CP were nearly the same. 3. The average relative humidity (RH) was lowest at WP showing 15.21%, but SP and CP had similar RH 28.79%, 28.02% respectively. 4. The average of calculated WBGT were the highest at the WP ($27.61^{\circ}C$) and the lowest at the SP ($23.64^{\circ}C$). The CP ($25.49^{\circ}C$) was in the middle of the others. As summery, compared with natural condition (CP), the wind blocking increased about $2.11^{\circ}C$ WBGT, but the shading decreased about $1.84^{\circ}C$ WBGT. So It can be apparently said that the open space with much shading trees, sheltering furnitures and well-delivered wind corridor can reduce useless and even harmful energy for human outdoor activity considerably in outdoor spaces.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Numerical modeling of secondary flow behavior in a meandering channel with submerged vanes (잠긴수제가 설치된 만곡수로에서의 이차류 거동 수치모의)

  • Lee, Jung Seop;Park, Sang Deog;Choi, Cheol Hee;Paik, Joongcheol
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.743-752
    • /
    • 2019
  • The flow in the meandering channel is characterized by the spiral motion of secondary currents that typically cause the erosion along the outer bank. Hydraulic structures, such as spur dike and groyne, are commonly installed on the channel bottom near the outer bank to mitigate the strength of secondary currents. This study is to investigate the effects of submerged vanes installed in a $90^{\circ}$ meandering channel on the development of secondary currents through three-dimensional numerical modeling using the hybrid RANS/LES method for turbulence and the volume of fluid method, based on OpenFOAM open source toolbox, for capturing the free surface at the Froude number of 0.43. We employ the second-order-accurate finite volume methods in the space and time for the numerical modeling and compare numerical results with experimental measurements for evaluating the numerical predictions. Numerical results show that the present simulations well reproduce the experimental measurements, in terms of the time-averaged streamwise velocity and secondary velocity vector fields in the bend with submerged vanes. The computed flow fields reveal that the streamwise velocity near the bed along the outer bank at the end section of bend dramatically decrease by one third of mean velocity after the installation of vanes, which support that submerged vanes mitigate the strength of primary secondary flow and are helpful for the channel stability along the outer bank. The flow between the top of vanes and the free surface accelerates and the maximum velocity of free surface flow near the flow impingement along the outer bank increases about 20% due to the installation of submerged vanes. Numerical solutions show the formations of the horseshoe vortices at the front of vanes and the lee wakes behind the vanes, which are responsible for strong local scour around vanes. Additional study on the shapes and arrangement of vanes is required for mitigate the local scour.

Implementation of PersonalJave™ AWT using Light-weight Window Manager (경량 윈도우 관리기를 이용한 퍼스널자바 AWT 구현)

  • Kim, Tae-Hyoun;Kim, Kwang-Young;Kim, Hyung-Soo;Sung, Min-Young;Chang, Nae-Hyuck;Shin, Heon-Shik
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.3
    • /
    • pp.240-247
    • /
    • 2001
  • Java is a promising runtime environment for embedded systems because it has many advantages such as platform independence, high security and support for multi-threading. One of the most famous Java run-time environments, Sun's ($PersonalJave^{TM}$) is based on Truffle architecture, which enables programmers to design various GUIs easily. For this reason, it has been ported to various embedded systems such as set-top boxes and personal digital assistants(PDA's). Basically, Truffle uses heavy-weight window managers such as Microsoft vVin32 API and X-Window. However, those window managers are not adequate for embedded systems because they require a large amount of memory and disk space. To come up with the requirements of embedded systems, we adopt Microwindows as the platform graphic system for Personal] ava A WT onto Embedded Linux. Although Microwindows is a light-weight window manager, it provides as powerful API as traditional window managers. Because Microwindows does not require any support from other graphics systems, it can be easily ported to various platforms. In addition, it is an open source code software. Therefore, we can easily modify and extend it as needed. In this paper, we implement Personal]ava A WT using Microwindows on embedded Linux and prove the efficiency of our approach.

  • PDF

A Study on the Original Landscape for the Restoration and Maintenance of Buyongjeong and Juhamnu Areas in Changdeokgung Palace (창덕궁 부용정과 주합루 권역의 복원정비를 위한 원형 경관 고찰)

  • Oh, Jun-Young;Yang, Ki-Cheol
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.24-37
    • /
    • 2021
  • This study was conducted to newly examine the original landscape of Buyongjeong(芙蓉亭) and Juhamnu(宙合樓) areas in Changdeokgung Palace(昌德宮), focusing on the modern period including the Korean Empire, and to derive useful research results for restoration and maintenance in the future. The study results can be summarized as follows. First, the artificial island in Buyongji(芙蓉池) was originally made up of a straight layer using well-trimmed processed stone. However, during the maintenance work in the 1960s and 1970s, the artificial island in Buyongji was transformed into a mixture of natural and processed stones. The handrail installed on the upper part of the artificial island in Buyongji is a unique facility that is hard to find similar cases. The handrail existed even during the Korean Empire, but was completely destroyed during the Japanese colonial period. Second, Chwibyeong(翠屛), which is currently located on the left and right of Eosumun(魚水門), is the result of a reproduction based on Northern bamboo in 2008. Although there is a view that sees the plant material of Eosumun Chwibyeong as Rigid-branch yew, the specific species is still vague. Looking at the related data and circumstances from various angles, at least in the modern era, it is highly probable that the Eosumun Chwibyeong was made of Chinese juniper like Donggwanwangmyo Shrine(東關王廟) and Guncheongung(乾淸宮) in Gyeongbokgung Palace(景福宮). Third, the backyard of Juhamnu was a space with no dense trees on top of a stone staircase-shaped structure. The stone stairway in the backyard of Juhamnu was maintained in a relatively open form, and it also functioned as a space to pass through the surrounding buildings. However, as large-scale planting work was carried out in the late 1980s, the backyard of Juhamnu was maintained in the same shape as a Terraced Flower Bed, and it was transformed into a closed space where many flowering plants were planted. Fourth, Yeonghwadang Namhaenggak(暎花堂 南行閣), which had a library function like Gyujanggak(奎章閣) and Gaeyuwa(皆有窩), was destroyed in the late 1900s and was difficult to understand in its original form. Based on modern photographs and sketch materials, this study confirmed the arrangement axis of Yeonghwadang Namhaenggak, and confirmed the shape and design features of the building. In addition, an estimated restoration map referring to 「Donggwoldo(東闕圖)」 and 「Donggwoldohyung(東闕圓形)」 was presented for the construction of basic data.

A Study on the Integrated Utilization of Nationally-Supported Research Vessels Using Cost-Benefit Analysis (비용-편익 분석을 통한 국가 해양 연구·조사선의 최적 통합활용 방안 연구)

  • Park, Cheong Kee;Park, Se Hun;Park, Seong Wook;Lee, Gun Chang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.719-730
    • /
    • 2017
  • Recently, oceanic research has been carried out investigating global scientific interests and the territorial management of national marine jurisdictional waters, including exclusive economic zones (EEZ) and the open seas. To meet the needs of ocean researchers pursuing these - objectives, acquiring advanced research infrastructure, including research vessels, large facilities, and equipment, is a top priority in ocean science. However, ocean science is a similar to space science, and securing resources and state-of-the-art technology can be expensive. Faced with these challenges, our study focused on establishing a strategy for the efficient operation and management of research vessels, attempting to establish benchmarks from foreign examples that can be adapted to suit the target context. The results of this study provide ways to identify operating systems that could increase the efficiency of joint-use research vessels. The different systems examined in this study included a joint-use committee-based management system (JCMS, Type 1), private enterprise entrusted operating system (PEOS, Type 2), institutional investment operating system (IIOS, Type 3), and commissioned executive operating system (CEOS, Type 4). The efficiencies of JCMS, PEOS, IIOS and CEOS were 9.17, 5.82, 11.2 and -1.72 %, respectively. Given the total costs involved, the most affordable operating system was IIOS. JCMS was the most cost-effective system based on a quantitative cost-benefit analysis, but IIOS also had an acceptable cost-benefit balance. An operational committee would be required and regulations and guidelines shoulde be established to employ, JCMS, while a strategy to yield independent revenue would be needed to utilize an IIOS system.