• 제목/요약/키워드: thermal sensitivity

검색결과 647건 처리시간 0.041초

마이크로 무아레 간섭계를 이용한 초정밀 변형 측정 (Nano-level High Sensitivity Measurement Using Microscopic Moiré Interferometry)

  • 주진원;김한준
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.186-193
    • /
    • 2008
  • [ $Moir{\acute{e}}$ ] interferometry is an optical method, providing whole field contour maps of in-plane displacements with high resolution. The demand for enhanced sensitivity in displacement measurements leads to the technique of microscopic $moir{\acute{e}}$ interferometry. The method is an extension of the $moir{\acute{e}}$ interferometry, and employs an optical microscope for the required spatial resolution. In this paper, the sensitivity of $moir{\acute{e}}$ interferometry is enhanced by an order of magnitude using an immersion interferometry and the optical/digital fringe multiplication(O/DFM) method. In fringe patterns, the contour interval represents the displacement of 52 nm per fringe order. In order to estimate the reliability and the applicability of the optical system implemented, the measurements of rigid body displacements of grating mold and the coefficient of thermal expansion(CTE) for an aluminium block are performed. The system developed is applied to the measurement of thermal deformation in a flip chip plastic ball grid array package.

경계적분방정식을 이용한 축대칭 열전도 고체의 형상설계민감도 해석 (Shape Design Sensitivity Analysis of Axisymmetric Thermal Conducting Solids Using Boundary Integral Equations)

  • 이부윤
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.141-152
    • /
    • 1993
  • 본 연구에서는 축대칭 열전도 고체의 형상설계민감도 해석을 위하여 2차원 문 제를 다룬 Lee, Choi와 Kwak의 방법을 축대칭 문제로 확장하였다.축대칭 형태로 표 시된 직접 및 간접 경계적분방정식의 정식화에 기초하여 전미분방접과 보조변수방법으 로 형상최적화 문제에서 발생하는 일반적인 성능 범함수의 형상설계민감도 공식을 유 도하고, 온도 및 열속의 제한조건에 이를 응용하였다. 제시된 민감도해석방법의 정 확성을 검증하기 위하여 해석적인 해를 갖는 원통문제와 구문제를 다루었는데, 두 문 제에 대하여 민감도 공식을 이용하여 수치계산된 결과를 해석적인 민감도와 비교하였 다. 또한 복잡한 수치해로서 냉각핀(cooling fin)문제를 다루었으며, 민감도 공식에 의한 계산 결과를 유한차분(finite difference)으로 수치미분한 결과와 비교하였다.

자계-열계 시스템의 3차원 위상최적설계 (3-D Topology Optimization of Magneto-Thermal Systems)

  • 심호경;왕세명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.939-941
    • /
    • 2005
  • This research presents a 3D multi-objective approach regarding both magnetic and thermal characteristics associated with design of C-core actuator. The adjoint variable topology sensitivity equations are derived using the continuum method for three dimension. The sensitivity is verified using the Finite Difference Method(FDM). Convection interpolation function is proposed for density method of topologies such that convection term can be taken into consideration for practical design in the process of the optimization.

  • PDF

Dry thermal development of negative electron beam resist polystyrene

  • Con, Celal;Abbas, Arwa Saud;Yavuz, Mustafa;Cui, Bo
    • Advances in nano research
    • /
    • 제1권2호
    • /
    • pp.105-109
    • /
    • 2013
  • We report dry thermal development of negative resist polystyrene with low molecular weight. When developed on a hotplate at $350^{\circ}C$ for 30 min, polystyrene showed reasonable high contrast and resolution (30 nm half-pitch), but low sensitivity. Resist sensitivity was greatly improved at lower development temperatures, though at the cost of reduced contrast. In addition, we observed the thickness reduction due to thermal development was higher for larger remaining film thickness, implying the thermal development process is not just a surface process and the more volatile chains below the top surface may diffuse to the surface and get evaporated.

Fabrication of a superheated emulsion based on Freon-12 and LiCl suitable for thermal neutrons detection

  • Sara Sadat Madani Kouchak;Dariush Rezaei Ochbelagh;Peiman Rezaeian;Majid Abdouss
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1425-1430
    • /
    • 2024
  • This study develops superheated emulsion detectors that are both sensitive to fast neutrons, and thermal neutrons owing to the exergonic 63Li(n, α)31H capture reaction caused by the 6Li-containing compound dispersed throughout the gel-like medium. The experimental research was conducted on two SEDs. One detector was an ordinary Freon-12 detector and the other was a Freon-12 detector containing 3.4 % (by weight) LiCl. In order to investigate the sensitivity of lithium-containing SEDs to thermal neutrons, two types of SEDs were simultaneously exposed to various flux levels of thermal neutrons from 241Am-Be neutron source inside a cylindrical tank filled with water. A Boron-lined proportional counter was used to estimate the thermal neutron flux and the relevant MCNP code was developed for flux and dose calculations in the prepared set-up around 241Am-Be source. The results demonstrate that there is a proportional relationship between the variations of SED response and the change in thermal neutron flux and dose. Also, the sensitivity of SED was estimated.

The Influence of Temperature and Strain Rate on the Mechanical Behavior in Uranium

  • Lee, Key-Soon;Park, Won-Koo
    • Nuclear Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.73-78
    • /
    • 1978
  • 온도 및 연신율변화 (strain-rate change)가 $\alpha$-uranium의 변형거동에 미치는 영향을 30$0^{\circ}C$에서 55$0^{\circ}C$까지 연구하였으며, strain rate sensitivity, activation volume, strain rate sensitivity exponent 및 dislocation velocity exponent을 조사하였다. 40$0^{\circ}C$이하에서 strain rate sensitivity exponent는 strain의 증가에 따라 증가하였으나 50$0^{\circ}C$이상에서는 strain의 증가에 따라 감소하는 경향을 나타냈다. 40$0^{\circ}C$이하에서는 strain에 의해 생기는 가공경화로 인한 내부 용력의 증가가 strain rate sensitivity exponent에 영향을 미치나 50$0^{\circ}C$이상에서는 많은 slip system이 변형에 기여하게 되므로 가공경화 보다는 thermal softening이 더 큰 영향을 미쳐서 strain rate sensitivity가 감소된다고 추측된다.

  • PDF

노심보충수탱크의 직접접촉응축에 대한 MARS의 계산능력평가 (ASSESSMENT OF MARS FOR DIRECT CONTACT CONDENSATION IN THE CORE MAKE-UP TANK)

  • 박근태;박익규;이승욱;박현식
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.64-72
    • /
    • 2014
  • This study aimed at assessing the analysis capability of thermal-hydraulic computer code, MARS for the behaviors of the core make-up tank (CMT). The sensitivity study on the nodalization to simulate the CMT was conducted, and the MARS calculations were compared with KAIST experimental data and RELAP5/MOD3.3 calculations. The 12-node model was fixed through a nodalization study to investigate the effect of the number of nodes in the CMT (2-, 4-, 8-, 12-, 16-node). The sensitivity studies on various parameters, such as water subcooling of the CMT, steam pressure, and natural circulation flow were done. MARS calculations were reasonable in the injection time and the effects of several parameters on the CMT behaviors even though the mesh-dependency should be properly treated for reactor applications.

가열 전극 통합 채널 공진기의 진공 환경 구동에 의한 열물성 측정의 민감도 향상 (Sensitivity Enhancement for Thermophysical Properties Measurements via the Vacuum Operation of Heater-integrated Fluidic Resonators)

  • 고주희;이정철
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.39-43
    • /
    • 2023
  • Microscale thermophysical property measurements of liquids have been developed considering the increasing interest in the thermal management of cooling systems and energy storage/transportation systems. To accurately predict the heat transfer performance, information on the thermal conductivity, heat capacity, and density is required. However, a simultaneous analysis of the thermophysical properties of small-volume liquids has rarely been considered. Recently, we proposed a new methodology to simultaneously analyze the aforementioned three intrinsic properties using heater-integrated fluidic resonators (HFRs) in an atmospheric pressure environment comprising a microchannel, resistive heater/thermometer, and mechanical resonator. Typically, the thermal conductivity and volumetric heat capacity are measured based on a temperature response resulting from heating using a resistive thermometer, and the specific heat capacity can be obtained from the volumetric heat capacity by using a resonance densitometer. In this study, we analyze methods to improve the thermophysical property measurement performance using HFRs, focusing on the effect of the ambience around the sensor. The analytical method is validated using a numerical analysis, whose results agree well with preliminary experimental results. In a vacuum environment, the thermal conductivity measurement performance is enhanced, except for the thermal conductivity range of most gases, and the sensitivity of the specific heat capacity measurement is enhanced owing to an increase in the time constant.