Acknowledgement
Supported by : 한국연구재단, 한국방사선안전재단
References
- 1998, Tower, S.N., Schulz, T.L. and Vijuk, R.P., "Passive and simplified system features for the advanced westinghouse 600 MWe PWR," Nucl. Eng. Des., Vol.109, pp.147-154.
- 2006, Schulz, T.L., "Westinghouse AP1000 advanced passive plant," Nucl. Eng. Des., Vol.236, pp.1547-1557. https://doi.org/10.1016/j.nucengdes.2006.03.049
- 1997, Chang, S.H., No, H.C., Baek, W.P., Lee, S.I. and Lee, S.W., "Conceptual desing of CARR passive PWR 1300MWe (CP1300)," Nucl. Eng. Int.
- 2013, Chang, S.H., Kim, S.H. and Choi, J.Y., "Design of integrated passive safety system (IPSS) for ultimate passive safety of nuclear power plants," Nucl. Eng. Des., Vol.260, pp.104-120. https://doi.org/10.1016/j.nucengdes.2013.03.018
- 1999, Tuunanen, J., Vihavainen, J., D'Auria, F. and Kimber, G., "Assessment of passive safety injection systems of ALWRs," Final report of the European Commission 4th Framework Programme Project FI4I-CT95-0004, Technical Research Centre of Finland.
- 2000, IAEA, "Natural circulation data and methods for advanced water cooled nuclear power plant designs," Proceedings of a Technical Committee meeting, Vienna, Austria.
- 2013, Wang, M., Tian, W., Qiu, S., Su, G. and Zhang, Y., "An evaluation of designed passive Core Makeup Tank (CMT) for China pressurized reactor (CPR1000)," Ann. Nucl. Energy, Vol.56, pp.81-86. https://doi.org/10.1016/j.anucene.2013.01.010
- 2006, Yonomoto, T. and Sibamoto, Y., "Summary on natural circulation phenomena observed in ROSA/AP600 tests," IAEA's Third Research Coordination Meeting, CEA, Cadarache, France.
- 1998, Lee, S.I. and No, H.C., "Gravity-driven injection experiments and direct-contact condensation regime map for passive high-pressure injection system," Nucl. Eng. Des., Vol.183, pp.213-234. https://doi.org/10.1016/S0029-5493(98)00174-5
- 1997, Lee, S.I. and No, H.C., "Assessment of RELAP5/MOD3.1 for direct-contact condensation in the core makeup tank of the CARR passive reactor," Ann. Nucl. Energy, Vol.24, pp.445-562.
- 1998, Lee, S.I. and No, H.C., "Improvement of direct contact condensation model of RELAP5/MOD3.1 for passive high-pressure injection system," Ann. Nucl. Energy, Vol.25, pp.677-688. https://doi.org/10.1016/S0306-4549(97)00115-1
- 2004, Thermal Hydraulic Safety Research Department, MARS code manual Vol. I: Code structure, system models, and solution methods, Korea Atomic Energy Research Institute.
- 2013, Chun, J.H., Lee, G.H., Bae, Y.J., Chung, Y.J. and Kim, K.K., "Performance Evaluation of SMART Passive Safety System for SBLOCA Using MARS Code," Transactions of Korean Nuclear Society Spring Meeting, Gwangju, Korea.
- 2001, Nuclear Safety Analysis Division, RELAP5 /MOD3.3 Code Manual Vol. I: Code structure, system models, and solution methods, Idaho National Engineering and Environmental Laboratory, USA.
- 1996, Wright, R.F., Hundal, R., Hochreiter, L.E., Friend M.T. and Ogrins, M., "Analysis and evaluation of the AP600 SPES-2 integral system tests," Proceedings of the 4th International Conference on Nuclear Engineering, NewOrleans, USA.
- 2013, Park, I.K., Lee, J.R., Lee, S.W., Yoon, H.Y. and Jeong, J.J., "An implicit code coupling of 1-D system code and 3-D in-house CFD code for multi-scaled simulations of nuclear reactor transients," Ann. Nucl. Energy, Vol.59, pp.80-91. https://doi.org/10.1016/j.anucene.2013.03.048