• 제목/요약/키워드: the pipe-to-soil potential

검색결과 33건 처리시간 0.026초

Statistical Approach for Corrosion Prediction Under Fuzzy Soil Environment

  • Kim, Mincheol;Inakazu, Toyono;Koizumi, Akira;Koo, Jayong
    • Environmental Engineering Research
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2013
  • Water distribution pipes installed underground have potential risks of pipe failure and burst. After years of use, pipe walls tend to be corroded due to aggressive soil environments where they are located. The present study aims to assess the degree of external corrosion of a distribution pipe network. In situ data obtained through test pit excavation and direct sampling are carefully collated and assessed. A statistical approach is useful to predict severity of pipe corrosion at present and in future. First, criteria functions defined by discriminant function analysis are formulated to judge whether the pipes are seriously corroded. Data utilized in the analyses are those related to soil property, i.e., soil resistivity, pH, water content, and chloride ion. Secondly, corrosion factors that significantly affect pipe wall pitting (vertical) and spread (horizontal) on the pipe surface are identified with a view to quantifying a degree of the pipe corrosion. Finally, a most reliable model represented in the form of a multiple regression equation is developed for this purpose. From these analyses, it can be concluded that our proposed model is effective to predict the severity and rate of pipe corrosion utilizing selected factors that reflect the fuzzy soil environment.

토양특성이 상수도관의 외부부식에 미치는 영향 평가 (Assessment of Soil Characteristics on External Corrosion of Water Pipes)

  • 배철호;김주환;박상영;김정현;홍성호;이경재
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.737-745
    • /
    • 2006
  • The goal of this study is to present an external pit corrosion rate($p_{ecr}$) model with considering both the age of pipe and the soil characteristics. The correlation of nonlinear exponential model among conventional empirical models was a little higher than other empirical models in the prediction of $p_{ecr}$ according to the age of pipe. However, there has been a limit to predict Peer with the model by using only a pipe age since installation as a variable. The soil analysis results from sixty nine samples showed that all of the samples were non corrosive in the assessment of ANSI/AWWA scoring system. The correlation of soil corrosion factors and $p_{ecr}$ was also low. The application result of linear and nonlinear regression models that soil characteristics only showed a low correlation with $p_{ecr}$ Proposed nonlinear regression model in this study, with considering both the age of pipe and the soil characteristics, showed a little higher correlation ($R^2=0.46$) than conventional model.

토양 매설 배관의 음극방식과 환경인자 간의 상관관계 (Relationship between the Cathodic Protection of Pipe Buried in Soil and Environmental Factors)

  • 최승헌;원석연;유영란;김영식
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.372-380
    • /
    • 2022
  • The external corrosion control of buried pipes can be achieved by a combination of coatings and cathodic protection to maximize effectiveness. One of the factors affecting cathodic protection is the environmental soil conditions. Because soil is a kind of electrolyte, the environmental conditions of soil may be changed by the atmospheric environment. Therefore, in this study, changes in environmental soil factors by atmospheric environmental factors were monitored. In cathodic protection, on-potential and off-potential were measured from December 2021 to July 2022. The effects of external environmental factors and soil environmental factors on cathodic protection were analyzed. Changes in outdoor temperature affected soil temperature, and soil conductivity had a proportional relationship with soil humidity, but outdoor humidity and precipitation did not significantly affect humidity and conductivity of the soil. In contrast, in cathodic protection, the on-potential was affected by temperature, humidity, the conductivity of the soil, and the anode used, but the off-potential was little affected by these factors.

무선전위측정시스템에 사용하는 아연전극 활용성 검토 (The Usability of Zinc Electrode using Wireless Measuring System of Electric Potential)

  • 이종락;임사환;김상오
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.177-180
    • /
    • 2006
  • This study is to make a basic study if solid zinc (Zn) can be used for buried reference electrode, so we examined the adequacy of zinc as reference electrode by using zinc which showed regular electrode for buried period. The deference of electric potential if zinc electrode for corrosion factor such as soil resistivity or pH didn't show fixed trend and there was no clear trend on the change of measurement period. From field test, it is known that the natural electric potential difference of CSE electrode and zinc electrode is 1,100mV, but the electric potential of zinc electrode for CSE electrode in the natural soil and copying soil was 1,094~1,158mV. There was no fixed trend on the change of measurement period and electric potential difference of zinc electrode for corrosion factors such as soil resistivity or pH. Consequently, there was 40~60mV of electric potential difference in every copying soil during the experiment measurement.

  • PDF

Numerical evaluation of buried composite and steel pipe structures under the effects of gravity

  • Toh, William;Tan, Long Bin;Tse, Kwong Ming;Raju, Karthikayen;Lee, Heow Pueh;Tan, Vincent Beng Chye
    • Steel and Composite Structures
    • /
    • 제26권1호
    • /
    • pp.55-66
    • /
    • 2018
  • In this paper, the response of an underground fibreglass reinforced plastic (FRP) composite pipe system subjected to realistic loading scenarios that may be experienced by an actual buried pipeline is investigated. The model replicates an arbitrary site with a length of buried pipeline, passing through a $90^{\circ}$ bend and into a valve pit. Various loading conditions, which include effects of pipe pressurization, differences in response between stainless steel and fibreglass composite pipes and severe loss of bed-soil support are studied. In addition to pipe response, the resulting soil stresses and ground settlement are also analysed. Furthermore, the locations of potential leakage and burst have also been identified by evaluating the contact pressures at the joints and by comparing stresses to the pipe hoop and axial failure strengths.

토양 특성 및 전기방식에 따른 연료 가스용 강관의 부식 차이에 관한 연구 (A Study on the Corrosivity according to Soil Characteristics and Electrolytic Protection for the Materials of Fuel Gas Pipe)

  • 임상식;김지선;류영돈;이진한
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.16-22
    • /
    • 2016
  • 연료가스용 탄소강관이 지하에 매설되는 경우 부식을 방지하기 위해 피복강관을 사용하고 있으며, 피복강관의 결함, 타공사, 시공시 피복의 손상에 대비하여, 방식전위를 이용하여 환원 분위기를 강제로 조성한다. 일반적으로 연료가스용 탄소강관이 지하에 매설된 경우 두 방법이 병행되어 사용되지만, 토양환경의 변화를 예측 할 수 없는 불확실성과 부식 정도 또는 피복의 손상 등 배관의 결함에 대해 육안으로 직접 관찰하기 어려운 문제가 공존한다. 매설배관의 부식이 발생하는 것을 직접적으로 관찰하기 어렵기 때문에, 이를 직접적으로 관찰하기 위한 방법 중 하나가 부식쿠폰을 이용한 방법이다. 본 연구에서는 3가지 토양(마사토, 진흙, 모래)과 방식전위 사용 여부에 따라 작성된 6가지의 시나리오를 토대로 약 1년간 부식쿠폰의 부식 정도를 파악하였다. 그 결과 방식전위가 흐르는 환경의 부식쿠폰은 부식이 전혀 발생하지 않았으며, 미방식 부식쿠폰은 모두 부식이 발생하였다. 토양에 따라서는 진흙에서 가장 적은 부식속도를 보였으며, 모래와 마사토는 유사한 경향을 갖는 것으로 확인되었다. 진흙의 경우 높은 함수량에 의해 국부부식이 발생하였으며, 모래에서 부식이 발생한 것은 모래에 함유된 화학적 성분에 기인한 것으로 확인되었다.

상수도 배관용 무선 원격 부식모니터링 시스템 (The Remote Wireless Corrosion Monitoring System for Water Pipeline)

  • 하태현;배정효;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.637-640
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in oder to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. In this paper, results of development about remote wireless corrosion monitoring system for water pipe line are presented briefly.

  • PDF

상·하수 배관재의 수 환경에서 부식진전도 연구 (Research of Corrosion Growth Degree According in Liquid Environment of Waterworks and Sewer Piping Material)

  • 박경동;기우태;유형주;김동욱
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.33-40
    • /
    • 2006
  • The quality of the supply water which is supplied to consumer is not the thing of water after filtrating but the thing of water from faucet through pipe. As a result, heavy metals and microorganism, that is the major materials, which cause the distrust of the supply water is generated by supply process. Especially, the heavy metal is generated by the corrosion of waterworks. Besides, rupture by corrosion of pipe becomes the factor of supply water's pollution in waterworks and the factor of pollution of the soil and environment in drain pipe. Therefore, this research examined the weight reduction electric potential measure to measure the corrosion degree of piping materials after testing the corrosion of piping materials(Copper Pipe, Galvanized Steel Pipe, Stainless Steel Pipe) which is generally used at the moment in various corrosion environments(subterranean water, supply water, 3.5% NaCl, 3.5% $HNO_3$). And let me show basic design data about problem occurrence such as leakage water, rust water, inside and outside corrosion from this.

  • PDF

지하철 누설전류 무선 원격 감시시스템 적용 사례 (A case study of remote wireless monitoring system for stray current due to subway system)

  • 배정효;하윤철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치 (DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF