• Title/Summary/Keyword: the distribution of water flow

Search Result 1,191, Processing Time 0.028 seconds

Evaluation of Heating and Cooling Thermal Output Characteristics of Prefabricated Steel Wall Panel System for Radiant Heating and Cooling (강판 마감형 조립식 벽패널 복사냉난방시스템의 냉난방 방열 특성 평가)

  • Lim, Jae-Han;Koo, Bo-Kyoung;Kim, Sung-Im;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.70-77
    • /
    • 2013
  • Recently the radiant panel heating and cooling system has been regarded as an alternative of low temperature heating and high temperature cooling by applying the renewable energy sources to the heating and cooling of buildings. Especially this system can be used as HVAC system alternatives in super high-rise buildings for energy saving and thermal comfort. Also it can be possible to reduce the plenum space because the minimum ventilation air will be supplied into the space. This study focused on the evaluation the basic characteristics of thermal output in prefabricated steel wall panel system for radiant heating and cooling. In order to evaluate the thermal output according to both various supply water temperatures and supply water flow rates, three-dimensional dynamic heat transfer analysis was performed. As results, for the heating mode, thermal output increased by 26% with the supply temperature increasing by $5^{\circ}C$. The surface temperature of panels range within $1{\sim}3^{\circ}C$. For the cooling mode, thermal output decreased by 18.2% with the supply temperature increasing by $2^{\circ}C$. The surface temperature of panels range within $0.5{\sim}1^{\circ}C$ and it was shown the even temperature distribution.

Highly filled AIN/epoxy composites for microelectronic encapsulation (반도체 봉지용 고충진 AIN/Epoxy 복합재료)

  • 배종우;김원호;황영훈
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.131-134
    • /
    • 2000
  • Increased temperature adversely affects the reliability of a device. So, package material should have high thermal diffusion, i.e., high thermal conductivity. And, there are several other physical properties of polymeric materials that are important to microelectronics packaging, some of which are a low dielectric constant, a low coefficient of thermal expansion (CTE), and a high flexural strength. In this study, to get practical maximum packing fraction of AIN (granular type) filled EMC, the properties such as the spiral flow, thermal conductivity, CTE, and water resistance of AIN-filled EMC (65-vol%) were evaluated according to the size of AIN and the filler-size distribution. Also, physical properties of AIN filled EMC above 65-vol% were evaluated according to increasing AIN content at the point of maximum packing fraction (highly loading condition). The high loading conditions of EMC were set $D_L/D_S$=12 and $X_S$=0.25 like as filler of sphere shape and the AIN filled EMC in this conditions can be obtained satisfactory fluidity up to 70-vol%. As a result, the AIN filled EMC (70-vol%) at high loading condition showed improved thermal conductivity (about 6 W/m-K), dielectric constant (2.0~3.0), CTE(less than 14 ppm/$^{\circ}C$) and water resistance. So, the AIN filled EMC (70-vol%) at high loading condition meets the requirement fur advanced microelectronic packaging materials.

  • PDF

Effects of Fertilizer Types on Pollutant Loadings from Rice Paddy Fields (비종에 따른 논에서의 배출부하량 영향평가)

  • Chang, Seung-Woo;Kang, Moon-Seong;Song, In-Hong;Jang, Jeong-Ryeol;Lee, Eun-Jeong;Park, Seung-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.111-119
    • /
    • 2011
  • The main objective of this study was to evaluate the effects of control-release fertilizer (CRF) on pollutant loadings from a small watershed. The Baran watershed, 386 ha in size, was selected as the study site, and the AGNPS (Agricultural Non-point Source Pollution) model was used to evaluate the effects of fertilizer types. Digital maps of digital elevation (DEM), slope distribution, channel, flow direction, landuse, soil, and curve number were extracted from the study watershed. Model parameters related to hydrology and water quality were calibrated and validated by comparing model predictions with the observed data collected for 2 years (1999 to 2000). Calibration and validation resulted in $R^2$ values of 0.75-0.91 for all the water quality parameters. All the paddy fields (21.2 %) of the study watershed were sprayed by either CRF or NPK (standard fertilizer). In CRF application, total nitrogen (TN) load was 4.9% less than NPK application, however total phosphorus (TP) load was 0.7 % more than NPK application. In CRF application, considering only paddy fields in the study area, TN load was 38.7 % less than NPK application. Using CRF in paddy fields could be one of the ways to reduce pollutant loadings from agricultural watersheds, however, in order to confirm it, more researches about effects of using CRF are necessary.

Calculation of Direct Runoff Hydrograph considering Hydrodynamic Characteristics of a Basin (유역의 동수역학적 특성을 고려한 직접유출수문곡선 산정)

  • Choi, Yun-Ho;Choi, Yong-Joon;Kim, Joo-Cheol;Jung, Kwan-Sue
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.157-163
    • /
    • 2011
  • In this study, after the target basin was divided into both overland and channel grids, the travel time from center of each grid cell to watershed's outlet was calculated based on the manning equation. Through this process, volumetric discharge was calculated according to the isochrones and finally, the direct runoff hydrograph was estimated considering watershed's hydrodynamic characteristics. Sanseong subwatershed located in main stream of Bocheong basin was selected as a target basin. The model parameters are only two: area threshold and channel velocity correction factor; the optimized values were estimated at 3,800 and 3.3, respectively. The developed model based on the tuned parameters led to well-matching results between observed and calculated hydrographs (mean of absolute error of peak discharge: 3.41%, mean of absolute error of peak time: 0.67 hr). Moreover, the analysis results regarding histogram of travel time-contribution area demonstrates that the proposed model characterizes relatively well hydrodynamic characteristics of the catchment due to effective rainfall.

Forced Flow Dryout Heat Flux in Heat Generating Debris Bed (열을 발생하는 Debris층에서의 강제대류 Dryout 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.273-280
    • /
    • 1986
  • The purpose of this study is to obtain the experimental data of the forced flow dryout heat flux in a heat generating debris bed which simulates the degraded nuclear reactor core after severe accident. An experimental investigation has been conducted of dryout heat flux in an inductively heated bed of steel particles with upward forced flow rising coolant circulation system under atmospheric pressure. The present observations were mainly focused on the effects of coolant mass flux, particle size, bed height, and coolant subcooling on the dryout heat flux The data were obtained when carbon steel particles in the size distribution 1.5, 2.5, 3.0 and 4.0 mm were placed in a 55 mm ID Pyrex glass column and inductively heated by passing radio frequency current through a multiturn work coil encircling the column. Distilled water was supplied with variation of mass flux from 0 to 3.5 kg/$\textrm{cm}^2$ s as a coolant in the tests, while the bed height was selected as 55 mm and 110 mm. Inlet temperature of coolant varied by 2$0^{\circ}C$ and 8$0^{\circ}C$. The principal results of the tests are: (1) Dryout heat flux increases with increase of upward forcing mass flux and particle size; (2) The dryout heat flux at the zero mass flux obviously depends on the Particle size as Previous studies; (3) The forced flow dryout heat flux in the shallow bed is somewhat higher than that in the deep bed,

  • PDF

Tube Erosion Rate of Water Wall in a Commercial Circulating Fluidized Bed Combustor (상용 순환 유동층 연소로 수관벽 전열관 마모속도)

  • Kim, Tae-Woo;Choi, Jeong-Hoo;Shun, Do-Won;Son, Jae-Ek;Jung, Bongjin;Kim, Soo-Sup;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.525-530
    • /
    • 2005
  • The erosion rate of water wall tube has been measured and discussed in a commercial circulating fluidized bed combustor (200 ton steam/hr, $4.97{\times}9.90{\times}28.98m\;height$). Tube thickness was measured with ultrasonic method. Severe tube erosion rate was observed in the splash region on all waterwalls including wingwalls. The tube erosion rate increased after an initial decrease as height from the distributor increased. The difference of erosion rate among wing walls was found due to unbalanced distribution of gas and solid flow rates. The erosion rate of the wing wall increased as location of the wing wall became closer to the center of combustor crosssection.

Spatial-temporal Distribution of Soil Moisture at Bumreunsa Hillslope of Sulmachun Watershed Through an Intensive Monitoring (설마천 유역 범륜사사면의 토양수분 시공간 집중변화양상의 측정)

  • Lee, Ga-Young;Kim, Ki-Hoon;Oh, Kyung-Joon;Kim, Sang-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.5 s.154
    • /
    • pp.345-354
    • /
    • 2005
  • Time Domain Reflectometry (TDR) with multiplex system has been installed to configure the spatial and temporal characteristics of soil moisture at the Bumreunsa hillslope of Sulmachun Watershed. An intensive surveying was performed to build a refined digital elevation model (DEM) and flow determination algorithms with inverse surveying have been applied to establish an efficient soil moisture monitoring system. Soil moisture data were collected through intensive monitoring during 380 hrs in November of 2003. Soil moisture data shows corresponding variation characteristics of soil moisture on the upper, middle and lower parts of the hillslope which were classified from terrain analysis. Measured soil moisture data have been discussed on the context of physical process of hydrological modeling.

The Development of Fully Coupled SWAT-MODFLOW Model (I) Model Development (완전 연동형 SWAT-MODFLOW 결합모형 (I) 모형의 개발)

  • Kim, Nam-Won;Chung, Il-Moon;Won, Yoo-Seung
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.6
    • /
    • pp.499-507
    • /
    • 2004
  • In this study, the fully coupled SWAT-MODFLOW model is developed by using the type of embedment MODFLOW in SWAT. Since SWAT model has semi distributed features, its groundwater component can't consider distributed parameters such as hydraulic conductivity, storage coefficient and spatially variable natures such as distribution of groundwater heads and pumping rate and so forth. The main purpose of this study is to overcome these limitations. This linkage is completed considering the interaction between stream network and aquifer to reflect boundary flow. To correspond HRU in SWAT to grid in MODFLOW, HRU-GRID conversion tool using DEM is newly suggested. As groundwater recharge of MODFLOW can be estimated accurately by SWAT model, the reliability of groundwater discharge and total runoff of watershed could be greatly enhanced.

A Study on Space Creation and Management Plan according to Characteristics by Type in Each Small-Scale Biotope in Seoul - Base on the Amphibian Habitats - (서울시 소규모 생물서식공간 유형별 특성에 따른 조성 및 관리방안 연구 - 양서류 서식지를 중심으로 -)

  • Park, Ha-Ju;Han, Bong-Ho;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.2
    • /
    • pp.110-126
    • /
    • 2024
  • This study conducted a classification of small-scale biological habitats created in Seoul to analyze and synthesize location characteristics, habitat structure, biological habitat functions, and threat factors of representative sites, as well as derive creation and management problems according to the ecological characteristics. The aim was to suggest improvement measures and management items. Data collected through a field survey was used to categorize 39 locations, and 8 representative sites were selected by dividing them into location, water system, and size as classification criteria for typification. Due to the characteristics of each type, the site was created in an area where amphibian movement was disadvantageous due to low or disconnected connectivity with the hinterland forest, and the water supply was unstable in securing a constant flow and maintaining a constant water depth. The habitat structure has a small area, an artificial habitat structure that is unfavorable for amphibians, having the possibility of sediment inflow, and damage to the revetment area. The biological habitat function is a lack of wetland plants and the distribution of naturalized grasses, and threats include the establishment of hiking trails and decks in the surrounding area. Artificial disturbances occur adjacent to facilities. When creating habitats according to the characteristics of each type, it was necessary to review the possibility of an artificial water supply and introduce a water system with a continuous flow in order to connect the hinterland forest for amphibian movement and locate it in a place where water supply is possible. The habitat structure should be as large as possible, or several small-scale habitats should be connected to create a natural waterfront structure. In addition, additional wetland plants should be introduced to provide shelter for amphibians, and facilities such as walking paths should be installed in areas other than migration routes to prevent artificial disturbances. After construction, the management plan is to maintain various water depths for amphibians to inhabit and spawn, stabilize slopes due to sediment inflow, repair damage to revetments, and remove organic matter deposits to secure natural grasses and open water. Artificial management should be minimized. This study proposed improvement measures to improve the function of biological habitats through the analysis of problems with previously applied techniques, and based on this, in the future, small-scale biological habitat spaces suitable for the urban environment can be created for local governments that want to create small-scale biological habitat spaces, including Seoul City. It is significant in that it can provide management plans.

Effect of Anionic Alkali Mineral Complex Barodon$^{(R)}$ on Body Growth and Testicular Development in Rats

  • Chung, Y.C;Kim, C.K.;Kim, I.;Kim, K.S.;J.W. Ryu;S.E. Yeon;Lee, E.S.;Park, S.I.;K.S. Jeon
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.39-39
    • /
    • 2001
  • Effects of Barodon$^{(R)}$ on body growth, histological changes in seminiferous tubules of testes and serum level of testosterone and FSH were examined in juvenile rats from 5 to 38 wks of age. All rats supplied feed and Barodon-added water(0, 0.1, 0.15, 0.3 and 1.0%) available ad libitum. DNA distribution of testicular cells from control rats obtained by flow cytometry was characterized by 4 peaks representing I : elongated, II round spermatids(1N), III: a variety of 2N cells and IV: 4N cells. Frequencies of 4 testicular cell types were calculated using cumulative DNA frequency distributions. Body growth from 18wk of age was significantly accelerated in rats supplied water with 0.15% Barodon compared to other groups. Testes weights tended to be greater in 0.15% Barodon-treated rats than in control, without significant difference. Diameter of seminiferous tubules advanced in 0.15-0.3% Barodon till 26 wk of age, but there was not significant different. Proportion of spermatids in seminiferous tubules was 48.4% at 6wk of age(round: 81.2% and elongated: 18.8% as proportion of total spermatids) and frequency of spermatids was higher in 0.3% Barodon group(57.1%) than in control(44.0%), but there was no significant difference. Serum testosterone of all groups significantly elevated at 18wk of age and level in 0.15% Barodon group was greatly higher than in others. Serum FSH at 10wks was greatly higher in 0.1-0.3% Barodon groups compared to control, but there were no significant differences. It is concluded that 0.15-0.3% Barodon treatment tended to induce precocious puberty in rats.

  • PDF