• Title/Summary/Keyword: tetracycline-HCI

Search Result 24, Processing Time 0.027 seconds

Micromorphometric change of Ti$O_2$ blast implant surface conditioned with tetracycline-HCI (산화 티타늄 블라스팅 임프란트 표면구조에 대한 염산 테트라싸이클린의 영향)

  • Lee, Jung-Min;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk;Heo, Seong-Joo
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.599-611
    • /
    • 2007
  • The present study was performed to evaluate the surface roughness and effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Ti$O_2$ surface Implant was utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for 0.5min, 1min, 1.5min, 2min, 2.5min and 3min respectively in the Tetracycline-HCI group. Then, specimens were measured surface roughness and processed for scanning electron microscopic observation. The results of this study were as follows. 1. Ti$O_2$ blast implant surface showed increased surface roughness 1.5 minute after treatment with Tetracycline-HCI. But, there were not significant differences in saline group after treatment. 2. Tetracycline-HCI group showed changed surface micro-morphology in SEM after 1.5 minute. There were not significant differences in saline group after treatment. 3. Between Tetracycline-HCI group and saline group, there were difference in surface roughness change and SEM micro-morphology. Tetracycline-HCI have influence on Ti$O_2$ blast implant surface. In conclusion, the detoxification with 50mg/ml Tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

Micromorphometric Influence of Anodic oxidation surface implant conditioned with tetracycline-HCI (양극 산화 임플란트 표면 구조에 대한 염산 테트라싸이클린의 영향)

  • Lim, Jeong-Taek;Chung, Jong-Hyuk;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.767-777
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Anodic oxidation surface were utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for ${\frac{1}{2}}min.$, 1min., $1{\frac{1}{2}}min.$, 2min., $2{\frac{1}{2}}min.$, and 3min. respectively in the test group. Then, specimens were processed for Ra Value test and scanning electron microscopic observation. The results of this study were as follows. 1. The anodic oxidation surface roughness tests don't show significant difference on conditioning with saline and Tetracycline-HCI. 2. The anodic oxidized surfaces showed the craterous structures. The surface conditioning with Tetracycline-HCI didn't influence on its micro-morphology. In conclusion, Anodic oxidation implant surface is stable to detoxificate with 50mg/ml Tetracycline-HCI of implant surface.

THE CHANGE OF THE ROOT SURFACE MORPHOLOGY BY DIFFERENT MODES OF TETRACYCLINE HYDROCHLORIDE CONDITIONING (Tetracycline Hydrochloride 적용방법에 따른 치근면 표면 형태 변화의 연구)

  • Rew, Seong-Hun;Moon, Jin-Kyun;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.76-88
    • /
    • 1995
  • The purpose of this was to evaluate the in vitro effects of different application modes of tetracycline HCI on dentin root surfaces. The study group was comprised of 30 teeth with advanced periodontal disease extracted before the start of periodontal therapy. The diseased root surface was vigorously root planed to expose dentin. The teeth were sectioned and cotton pellets. soaked in a saturated solution of tetracycline HCI, were either "placed" or "burnished" on the prepared root surface for 3, 5 min. respectively. Control surfaces were similarly treated with root planing only. Following the various treatments, teeth were fixed. dehydrated, critical point dried, and coated for scanning electron microscopic(SEM) evaluation. The surfaces of tetracycline HCI treated specimens considerably differed from specimens treated with root planing only. Results demonstrated that root-planed, no-tetracycline HCI specimens had amorphous, irregular surface which corresponded to a smear layer. Tetracycline HCI specimens exhibited collagen fibers and dentinal tubules exposed by the removal of the smear layer. Although some differences were seen in surface structures among some specimens. "burnished" application causes more extensive change than "placed" application, and application time of the tetracycline HCl did not seem to have any major impact on the surface morphology.

  • PDF

The effects of tetracycline-HCI on SLA implant surface structure (염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향)

  • Sea, Mi-Ran;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.

Micromorphometric change of implant surface conditioned with tetracycline-HCI;Hydroxyapatite surface (염산 테트라싸이클린이 HA 임플란트 표면구조에 미치는 영향)

  • Yang, Dong-Il;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.779-789
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Implant with hydroxyapatite surface was were utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution and sterilized saline for ${\frac{1}{2}}min.$, 1min., $1{\frac{1}{2}}min.$, 2min., $2{\frac{1}{2}}min.$, and 3min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation and measured surface roughness by optical interferometer. The results of this study were as follows. 1. Hydroxyapatite surface showed that round particles were deposited irregularly. 2. The roughness of surfaces conditioned with Tetracycline-HCI and saline was lessened and the cracks were increased relative to the application time. In conclusion, the detoxification with 50mg/ml Tetracycline-HCI must be applied respectively with appropriate time according to hydroxyapatite implant surfaces.

The influence of tetracycline-HCI for micromorphology of Thermal dual acid etched surface implants (염산 테트라싸이클린이 이중 산부식 임플란트 표면 구조에 미치는 영향)

  • Jeong, Do-Min;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.265-275
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Implants with thermal dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ Tetracycline-HCI solution and sterilized saline for O.5min, 1min, 1.5min, 2min, 2.5min and 3min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation and measured surface roughness by optical interferometer. The results of this study were as follows. 1. The thermal dual acid etched surfaces showed many small peaks and valleys distributed overall surface. 2. The surface conditioning with Tetracycline-HCI and saline didn't influence on its micromorphology. In conclusion, the implant with thermal dual acid etched surface has a protective micromorphology from the detoxification with $50mg/m{\ell}$ Tetracycline-HCI and a scrubbing with cotton pellet. Therefore, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI is an effective method for peri-implantitis in case implants with thermal dual acid etched surface.

SCANNING ELECTRON-MICROSCOPIC STUDY OF THE EFFECT OF CITRIC ACID AND TETRACYCLINE HCL CONDITIONING ON DISEASED ROOT SURFACE (구연산과 염산트라싸이클린이 치근면 탈회에 미치는 효과에 대한 주사전자현미경적 연구)

  • Kim, Young;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.24-34
    • /
    • 1995
  • The purpose of this study was to compare effects of demineralization of citric acid and tetracycline HCI on periodontally involved root surface. Twelve periodontally involved single rooted teeth were used. After scaling and root planing, root conditioning with citric acid and tetracycline HCI were carried and the teeth were processed scanning electron microscopic observation.The results were as follows: The scaled root surface was covered by much debris and calculus. The effect of demineralization of citric acid and tetracycline HCI was more reduced on scaling group than root planing group, because of hypermineralization of cementum surface and demineralization effect on root surface of tetracycline HCI showed tendency to reduction. The root planed group displayed more smooth root surface than scaling group, the surface was covered by smear layer, thus no exposure of dentinal tubule opening and collagen fiber, especially after root planing, citric acid and tetracycline HCl treated group showed exposure of dentinal tubule and collagen fiber, thus it was thought that new connective tissue attachment could be acquired.

  • PDF

Effect Of Tetracycline And Root Planing Methods On The Root Surface (치주과용 쿠렛과 Roto bur를 이용한 치근면 활택술을 시행한 치근의 변화 및 치근에 도포된 Tetracycline HC1의 효과에 대한 비교 연구)

  • Park, Hae-Seung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.191-203
    • /
    • 1997
  • Recently, alteration on chemical treatment on the root and removal of pathologic bacteria, which is the main reason for periodontal disease, by complete removal of infected cementum layer was been emphasied In this study, teeth extracted due to periodontal disease were root planed using periodontal curette and roto bur. Then they were treated with different concentration of Tetracycline HCI at different time. The state of root surface and change in the pre and post treatment was observed. The results were as follows. 1. The group treatment with periodontal curette and saline showed remaining plaque, debris and irregular surface and no dentianl tubule orifice could be seen. 2. The group treatment with periodontal curette and tetracycline HCI showed process compoed with decacified material and there was concanity seemed to be a lacunae of cementocyte. 3. The group treatment with roto bur and saline, there was no remaning plaque and partial dentinal tubule orifice could be seen but smear layer covering them.4. The group treatment with roto bur and tetracycline HCI showed various shape and size dentinal tubule orifice could be seen. From the results, roto bur showed cleaner surfaces than treatment with periodontal curette. But still smear layer existed. Thus for regeneration of periodontal tissue, chemical treatment using tetracycline HCI should follow roto bur treatment. And it is considered that the treatment time is more important than the concentration of tetracycline HCl.

  • PDF

Micromorphometric change of implant surface conditioned with Tetracycline-HCl : HA and Etched surface (염산테트라싸이클린의 적용시간에 따른 특수 가공된 임프란트 표면 변화)

  • Han, Ju-Young;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.731-744
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, HA-coated surface and dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-HCL solution for ${\frac{1}{2}}$min., 1min., $1{\frac{1}{2}}$min., 2min., and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The etched surfaces showed the honey comb structures. The surface conditioning with tetracycline-HCI didn't influence on its micro-morphology. In conclusion, the detoxification with $50mg/m{\ell}$ tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

Microstructural Change of Porous Surface Implant conditioned with Tetracycline-hydrochloride (염산티트라싸이클린의 적용시간에 따른 다공성 임프란트 표면 미세구조의 변화)

  • Jeong, Jae-Wook;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.319-334
    • /
    • 2006
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline-hydrochloride(TC-HCI) on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and porous surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml TC-HCI solution for $\frac{1}{2}$ min., 1 min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}$ min. respectively in the test group and with no treatment in the control group. Then, specimens were processed for scanning electron microscopic observation. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml TC-HCI solution, in general, test specimens were similar to control. 3. In the porous surfaces, the control specimen showed spherical particles of titanium alloy and its surface have a few shallow ridges. The roughness of surfaces conditioned with tetracycline-HCI was lessened and seen crater-like irregular surfaces relative to the application time. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCI solution. But the porous surfaces conditioned with tetracycline-HCI solution began to be slightly changed from 2 min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.