• Title/Summary/Keyword: test standard

Search Result 8,477, Processing Time 0.037 seconds

A Study on Standard Process of Risk Management for Defense Systems Test Works (무기체계 시험업무에 대한 리스크 관리 표준 프로세스 연구)

  • Taeheum Na;Dongeun Heo;Youngmin Kim;Jooyeoun Lee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.364-374
    • /
    • 2024
  • Today, risks created by uncertainty must be managed for successful project execution. From this perspective, applying a risk management process is very important for successful defense systems test works. This paper describes 'the implentation of risk management process for test work' carried out by DTERI's process improvement activities. In this study, the concept of risk management process, and details of the risk management process are examined through PMBOK and ISO/IEC/IEEE 15288, CMMI. After that, we defined 'Standard Process for Risk Management' of defence systems test works. And, we describe 'Risk Management Function' of DTERI's Project Management System(PMS) and the risk management process of DTERI. Finally, the effectiveness of the risk management standard process is verified through quantitative analysis.

An execution of the performance test for EMU (도시철도차량의 성능시험 시행 및 현황)

  • 김원경;정종덕;홍용기;김명룡;배창한
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.131-136
    • /
    • 2002
  • Performance test is carried out in accordance with "performance test standard for Electrical Multiple Unit", noticed by Ministry of Construction & Transportation in 2000. The object of this standard is to ensure that vehicle is tested after completion and before entry into service. Performance test is classified by type test to be carried out for the first car and its components in order to verify their performance and by routine test to be carried out on the whole quantity in order to prove the performance of individual items. Scope of the test is divided by components, completed car, preliminary adjustment test and running test on main line. The paper introduces a testing procedure and an execution method of the performance test.

  • PDF

Optimum Compaction Test of Roller Compacted Concrete Pavement (롤러전압 콘크리트포장의 적정 다짐실험 방안 고찰)

  • Chung, Gun Woo;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.27-33
    • /
    • 2015
  • PURPOSES : To ensure appropriate RCC properties with sufficient strength development and workability, it is necessary to secure a proper level of consistency. It is also necessary to secure maximum dry density, which is an important factor for increasing the interaction of aggregate interlocking, leading to an augmentation of RCC strength. On the other hand, the dry density of RCC can be changed owing to the compaction conditions, water content, and particle size distribution. A Proctor test and a modified Proctor test were used for determining the optimum water content needed to achieve maximum dry density with different amounts of compaction energy. A Vebe test, on the other hand, was used for checking the level of consistency, which is important for producing a workable mixture. METHODS : To confirm the degree of compaction at various particle sizes, RCC mixtures with different sand/aggregate ratios were evaluated. The Proctor test and modified Proctor test were applied to these mixtures to check the effect of the aggregate gradation and compaction energy on the maximum dry density and optimum water content. During each test, three specimens were produced for all types of water content under each aggregate gradation. A compaction curve and the optimum water content and maximum dry density for each aggregate gradation were then obtained for both tests. The range of water content for the appropriate consistency of each aggregate gradation was determined through a Vebe test. The optimum water content was then evaluated based on this range. RESULTS : The compaction test results show that the modified Proctor test provides a higher maximum dry density and lower optimum water content compared with the standard Proctor test. For the modified Proctor test, two cases of aggregate gradation (s/a = 30% and 70%) had the optimum water contents outside of the appropriate water content range. For the standard Proctor test, on the other hand, none of aggregate gradations provided the optimum water content within the desired range. CONCLUSIONS : The modified Proctor test should be used for an RCC mixture design because it can provide adequacy between maximum dry density and consistency. Moreover, the compaction roller has become highly developed for higher compaction energy.

A study on the Estimation of Standard Heating City Gas Consumption of Apartment Housing (공동주택의 난방용 도시가스 표준사용량 산정에 관한 연구)

  • Shim, Yun-Hee;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.89-97
    • /
    • 2006
  • Our Housing culture continuously changes for the correspondence to social development and changes of economy, and be developing. A massive apartment complex continuously increased, and According to this in our country heating energy consumption of a residential building is continuously increasing at country me whom was limited in order to raise efficient residential land use and diffusion ratio of house. If confirm an element to be able to reduce use of a heating energy, and there is saving possibility to parts of energy saving, this study will present the standard amount used with bases to the gas amount used for heating and Field Test data about room temperature. Execute simulation with building balance (public area, a plain), the gas amount useds such as incense of a building, indoor setting temperature ($^{\circ}C$), a position of an apartment house etc. to affect the energy amount used of a valuation object building of a variable through Field Test and research on the actual condition. Calculate the standard amount used of city gas for winter season heating of a comparative analysis apartment house to data value getting the above results through Field Test and simulations with bases.

The effect of short and long duration sintering method on microstructure and flexural strength of zirconia (단시간과 장시간의 소결방법에 따른 지르코니아의 굴곡 강도와 미세구조의 변화)

  • Lee, Ha-Bin;Lee, Tae-Hee;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.73-79
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the influence of short and long duration sintering on microstructure and flexural strength of zirconia. Methods: To conduct three-point bending test, Zirconia specimens are milled according to ISO 6872 guidelines(N=18, n=9 per group). Two specimens group(n=8) is sintered for 10 hours(Standard schedule) and 3 hours(Speed schedule) at the peak temperature of 1550℃ with silicon carbide sintering furnace. Flexural strength of specimens are measured by instron. After coating each specimen(n=1), microstructure of specimens is observed using Scanning Electron Microscope(SEM). T-test was utilized to statistically assess the data. Results: The mean and standard deviation value of the flexural strength for standard schedule group are 578.15±57.48Mpa, that of speed schedule are 465.9±62.34Mpa. T-test showed significant differences in flexural strength between two zirconia specimen group which applied standard schedule and speed schedule respectively(p<0.05). Conclusion: The result of this study showed that the increase in sintering time led to increased grain size, and also to a positive effect on the flexural strength.

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

The use of neural networks for the prediction of the settlement of pad footings on cohesionless soils based on standard penetration test

  • Erzin, Yusuf;Gul, T. Oktay
    • Geomechanics and Engineering
    • /
    • v.5 no.6
    • /
    • pp.541-564
    • /
    • 2013
  • In this study, artificial neural networks (ANNs) were used to predict the settlement of pad footings on cohesionless soils based on standard penetration test. To achieve this, a computer programme was developed to calculate the settlement of pad footings from five traditional methods. The footing geometry (length and width), the footing embedment depth, $D_f$, the bulk unit weight, ${\gamma}$, of the cohesionless soil, the footing applied pressure, Q, and corrected standard penetration test, $N_{cor}$, varied during the settlement analyses and the settlement value of each footing was calculated for each method. Then, an ANN model was developed for each traditional method to predict the settlement by using the results of the analyses. The settlement values predicted from the ANN model were compared with the settlement values calculated from the traditional method for each method. The predicted values were found to be quite close to the calculated values. It has been demonstrated that the ANN models developed can be used as an accurate and quick tool at the preliminary designing stage of pad footings on cohesionless soils without a need to perform any manual work such as using tables or charts. Sensitivity analyses were also performed to examine the relative importance of the factors affecting settlement prediction. According to the analyses, for each traditional method, $N_{cor}$ is found to be the most important parameter while ${\gamma}$ is found to be the least important parameter.

A Study on the Standard of Test Method for Estimation of Usage Environment Safety and Performance of U-health Medical Device (유헬스케어의료기기의 사용환경 안전성 및 성능평가를 위한 표준시험방법 연구)

  • Park, S.K.;Cha, J.H.;Hur, C.H.;Park, K.J.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • According to graying of population and income enlargement of people, interest about U-Healthcare of new form fusing with IT technology are enlarged. Need a estimation technology and standard of test method for safety and performance considering usage environment of U-Healthcare medical device. In this research, developed the standard of test method for usage environment safety and performance of U-Healthcare medical device referring IEC standards and KS standards.

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

A Study on the Standard Criteria of Solid Particle Separation Test for Marine Centrifugal Purifier (선박용 정유기 고형분 분리 성능시험 규격기준에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1028-1034
    • /
    • 2007
  • In order to establish a criteria of solid particle separation performance test on marine centrifugal purifier at factory acceptance test, an investigation had been done on criteria of test standards, regulations and test specifications of purifier manufactures. KS V 7836, fuel oil and lubricating oil purifiers for marine use-centrifugal type, the criteria of solid particle separation is studied in the point of reality, restricts and analysis method. It is proposed that a reasonable criteria and analysis method should be adopted, and the current criteria shall be revised to adequate levels considering reasonable basis and industrial technology levels. Also, the test analysis conceptions, separation efficiency method and particle size restriction method, are reviewed to fulfil separation performance test for marine centrifugal purifiers.