• Title/Summary/Keyword: tendon-driven

검색결과 29건 처리시간 0.025초

새로운 와이어 구동방식 외골격 보조기의 설계 및 제어 (Design and Control of a Novel Tendon-driven Exoskeletal Power Assistive Device)

  • 공경철;전도영
    • 제어로봇시스템학회논문지
    • /
    • 제11권11호
    • /
    • pp.936-942
    • /
    • 2005
  • Recently the exoskeletal power assistive equipment which is a kind of wearable robot has been widely developed to help the human body motion. For the elderly people and patients, however, some limits exist due to the weight and volume of the equipments. As a feasible solution, a tendon-driven exoskeletal power assistive device fur the lower body, and caster walker are proposed in this research. Since the caster walker carries the heavy items, the weight and volume of the wearable exoskeleton are minimized. The key control is used to generate the joint torque required to assist motions such as sitting, standing and walking. Experiments were performed for several motions and the EMG sensors were used to measure the magnitude of assistance. When the motion of sitting down and standing up was compared with and without wearing the proposed device, the $25\%$ assistance was acquired.

텐던 구동 마스터-슬레이브 조작기 최적 정적 출력 되먹임 제어 (Optimal Static Output Feedback Control of Tendon Driven Master-Slave Manipulator)

  • 강민식;이종광;윤지섭;박병석;김기호
    • 제어로봇시스템학회논문지
    • /
    • 제15권10호
    • /
    • pp.1039-1046
    • /
    • 2009
  • In this work, a bilateral control for a master-slave manipulator system which will be used for handling objects contaminated by radioactivity has been addressed. The links of manipulators are driven independently by individual motors installed on the base and the driving torque is transmitted through pre-tensioned tendons. The measurable variables are the positions and rates of master/slave motors. In the consideration of the flexibility of the tendon and available measurements for control, we proposed an optimal static output feedback control for possible bilateral control architecture. By using modal analysis, the system model is reduced to guarantee the detectability which is a necessity for the static output feedback control design. Based on the reduced model, the control gains are determined to attenuate vibration in the sense of optimality. The feasibility of the proposed control design was verified along with some simulation results.

마스터-슬레이브 조작기에서 제한된 힘반영제어기 구조를 고려한 Tendon 설계 (Tendon Design for Master-slave Manipulator in Consideration of Constrained Force Reflection Control Structure)

  • 강민식;윤우현
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1043-1052
    • /
    • 2009
  • In this work, a master-slave manipulator system which will be used for handling objects contaminated by radioactivity has been addressed. The links of manipulators are driven independently by individual motors installed on the base and the driving torque is transmitted through pre-tensioned tendons. Since the measurable variables are the positions and rates of master/slave motors, only a constrained specific bilateral control structure is available. In the consideration of the flexibility of the tendon and constrained control structure, we derived a necessity for tendon design to prevent uncontrollable vibration mode through a modal analysis. Based on a reduced rigid body model, a control design was suggested and tendons were selected. The feasibility of the proposed analysis and tendon design were verified along with some simulation results.

건구동식 로봇 의수용 착용형 인터페이스 (A Wearable Interface for Tendon-driven Robotic Hand Prosthesis)

  • 정성윤;박찬영;배주환;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제16권4호
    • /
    • pp.374-380
    • /
    • 2010
  • This paper proposes a wearable interface for a tendon-driven robotic hand prosthesis. The proposed interface is composed of a dataglove to measure finger and wrist joint angle, and a micro-control board with a wireless RF module. The interface is used for posture control of the robotic hand prosthesis. The measured joint angles by the dataglove are transferred to the main controller via the wireless module. The controller works for directly controlling the joint angle of the hand or for recognizing hand postures using a pattern recognition method such as LDA and k-NN. The recognized hand postures in this study are the paper, the rock, the scissors, the precision grasp, and the tip grasp. In experiments, we show the performances of the wearable interface including the pattern recognition method.

근전도에 기반한 근력 추정 (EMG-based Prediction of Muscle Forces)

  • 추준욱;홍정화;김신기;문무성;이진희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1062-1065
    • /
    • 2002
  • We have evaluated the ability of a time-delayed artificial neural network (TDANN) to predict muscle forces using only eletromyographic(EMG) signals. To achieve this goal, tendon forces and EMG signals were measured simultaneously in the gastrocnemius muscle of a dog while walking on a motor-driven treadmill. Direct measurements of tendon forces were performed using an implantable force transducer and EMG signals were recorded using surface electrodes. Under dynamic conditions, the relationship between muscle force and EMG signal is nonlinear and time-dependent. Thus, we adopted EMG amplitude estimation with adaptive smoothing window length. This approach improved the prediction ability of muscle force in the TDANN training. The experimental results indicated that dynamic tendon forces from EMG signals could be predicted using the TDANN, in vivo.

  • PDF

다중 DC모터를 이용한 역감처리 (Force Display Processing using Multiple DC motors)

  • 강원찬;김동옥;김원배;신석두;김영동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.183-188
    • /
    • 2001
  • In this paper, we have developed a new Force-Display system using tendon-driven method based multiple DC motors. The proposed system is based on the HIR Lab Haptic library, which calculates the real position and renders the reflecting force data to device rapidly. The system is composed of device based tendon- driving method, high-speed controller and Haptic rendering library. The developed system will be used on constructing the dynamical virtual environment. To show the efficiency of our system, we designed simulation program, which an display the moving force (attaching, grabbing, rotating) on two virtual points. As the result of the experiment, our proposed system shows much higher resolution than any others.

  • PDF

다관절 로보트 손의 설계 (Design on the articulated robotic hand)

  • 백상은;진상태;성흥석;이쾌희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.276-280
    • /
    • 1993
  • An articulated, multifinger mechanical hand can carry out grasping and manipulation operations on objects of different type and shape. In this paper the architecture of the mechanical hand is presented. Joints are driven by two antagonist tendons. Strain gauges are used to derive tendon tensions, and located in the palm of the hand. Angular defection of the joints is measured by Hall effect sensors attached to the joints. A multiprocessor-based architecture for controlling the hand is illustrated.

  • PDF

Applications of Gelatin in Food and Biotechnology

  • Yang, Jae-Sung
    • Preventive Nutrition and Food Science
    • /
    • 제2권3호
    • /
    • pp.263-268
    • /
    • 1997
  • Gelatin is a high molecular weight polypeptide derived fro mcollgen, theprimary protein component of animal connective tissues, which include bone, skin and tendon. Gelatin is usually produced from two different sources of raw materials (skins or bones) which are processed in two ways(line or acid). According to this pretreatment, gelatin can be divided into elatin type A(acid) and B(lime). The market is essentially driven by thre demand sectors: food, harmaceuticals(capsules) and photography. Although there is some potential threat in the photography sector, the oher tow sectors are well placed for futher growth.

  • PDF

Development of a coupled tendom driven robot hand

  • Choi, H.R.;Lee, Y.T.;Kim, J.H.;Chung, W.K.;Youm, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.185-190
    • /
    • 1993
  • The POSTECH Hand adopting coupled tendon driven technique with planar two fingers is developed. The hand is designed to emulate principal motions of the human hand which has two and three joints respectively. Its kinematic parameters are determined through a parameter optimizing technique to aim at improving the isotropy of fingertip motions with new criterion functions of design. For the control of the hand, tension and torque control algorithms are developed. Based on the virtual stiffness concept, we develop the stiffness control method of a grasped object with redundant finger mechnism and investigate experimentally.

  • PDF