• 제목/요약/키워드: surge protection device

검색결과 73건 처리시간 0.019초

RCD와 SPD의 접속 위치에 따른 보호협조 (Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices)

  • 이복희;박희열;신건진;배관영;류춘형;이강희
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.

내장 순시 트립장치를 이용한 MOV의 열폭주 보호와 SPD의 안전성 개선 (Protection of MOV Thermal Runaway and Safety Improvement of SPD using Built-in Instantaneous Trip Device)

  • 김주철;전주술;기채옥;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • SPDs are increasingly being used against lightning and switching surge according to the applicable revised standard and equipotential grounding system. SPDs are equipped usually with a MOV voltage regulating element. The MOV, however, always is exposed to the danger of thermal runaway resulting from inrushing temporary overvoltage and deterioration. In this paper, the authors made two prototype SPDs built-in Instantaneous trip device and analyzed their limiting voltage through test of the MOV breakdown. As the result of the analysis, the SPDs built-in Instantaneous trip device was proven to be effective for protecting MOV against thermal runaway and Instantaneous trip device react for limiting voltage is considered that is applicable to SPD.

전기철도환경하에서의 서지방호용 절연변압기 제작 및 성능평가 (Manufacture and Performance Evaluation of Insulating Transformer for surge protection under Electric Railway Environments)

  • 이강원;김명룡;온정근;박대원;박건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.176-177
    • /
    • 2006
  • The main aim of the paper is the study of the surge voltages in electric railway signal security system. Hence these studies will provide means of introducing a suitable protective device insulating transformer. This influences the surge voltage interrupting capacity using surge arresters and bypass capacitors. This circuit can be used for investigating surge phenomenon in electric railway signal security system. In this paper a insulating transformer has been introduced for the reduction of surge voltages in the above circuit model and performance evaluation.

  • PDF

인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선 (Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module)

  • 김주철;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

Data Transmission over Power Line with Lightning Protection Devices

  • Kim, Sungeon;Jeon, Taehyun
    • International journal of advanced smart convergence
    • /
    • 제2권1호
    • /
    • pp.27-29
    • /
    • 2013
  • This paper discusses comparative analysis of the effects of surge protection devices (SPD) upon the power line communication channels. The quality of the data transmission channel is measured based on the data rate for the various channel parameters which include channel length and application method of the lightning protection device. The performance measurements are also carried out for various lengths of the communication channel. Experiment results show that specific combination of SPDs applied in the network causes severe degradation of the channel quality which is associated with the combination of grade levels and channel lengths.

저압 전기설비의 과전압 억제 필요성 판단 (Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations)

  • 이주철;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발 (Development of a Surge Protective Device for Computer Network to International Standards)

  • 박대원;송재용;한주섭;길경석
    • 한국정보통신학회논문지
    • /
    • 제9권6호
    • /
    • pp.1253-1259
    • /
    • 2005
  • 본 논문은 외부의 서지로부터 컴퓨터 네트워크회로의 보호를 위한 서지방호장치에 대하여 기술하였다. 서지방호장치는 동작속도가 빠른 아발란시 다이오드와 에너지 내량이 큰 가스튜브의 하이브리드형으로 구성하였으며, 고주파 대역에서의 삽입손실을 줄이기 위하여 고속회복 다이오드를 사용하였다. 제안한 서지전압 차단장치의 성능 평가를 위하여 국제규격 IEC 61000-4-5 및 IEC 61643-21에 따라 서지차단특성과 신호전송 특성평가를 수행하였다. 실험결과로부터 본 서지차단장치는 국제규격에 제시된 서지차단특성을 만족하였으며, -3dB의 고역차단 주파수가 204 MHz로 100 Mbps급 근거리 통신네트워크에 적합한 특성을 나타내었다.

전지관리장치(BMS)의 서지내성 성능향상 기법 (Surge Immunity Performance Enhancement Techniques on Battery Management System)

  • 김용성;임성정;서우현;정중일
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.

SPD의 설치조건이 보호효과에 미치는 영향 (Protection Effects Associated with the Conditions for the Installations of SPDs)

  • 이복희;이동문;이승칠
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.60-67
    • /
    • 2006
  • 이 논문은 서지보호기의 설치조건에 따른 보호효과에 대하여 기술하였으며, 뇌서지로부터 정보통신설비를 효과적으로 보호하는 설치기법을 제안하기 위해 서지보호기의 보호효과에 미치는 설치위치, 분기회로의 길이, 배선방법, 전선관 재료의 영향에 대해서 실규모 조건에서의 실험을 수행하였다. 그 결과, 보호하고자 하는 각각의 전자기기의 입력단에 서지보호기를 설치하는 것이 효과적이며, 선간에 서지보호기를 설치할 때는 접속선의 길이가 최소가 되도록 하는 배선방법이 효과적이다.

전원계통의 접지방식 및 배선방식에 따른 서지보호기의 효과 (REffects of Surge Protective Devices with Respect to Types of System Grounding and Wiring Methods)

  • 이수봉;이복희;길형준
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.90-99
    • /
    • 2004
  • 고도 정보화 사회의 발달과 함께 정보통신 설비는 빠른 전송속도를 필요로 하며, 지능형 산업설비와 행정, 금융, 교통시스템과 같은 사회시스템은 집적회로와 초소형 반도체로 구성되므로 원격감시, 조작에 의해 점차적으로 자동화 되어가고 있다. 이와 같은 현대의 초소형 전자회로는 뇌 서지에 의해 흔히 손상을 입을 수 있으며, 뇌 과전압으로부터 전자회로의 보호에 관심이 집중되고 있다. 본 논문은 일반주택에서 뇌 서지로부터 초소형 컴퓨터와 같은 전자기기의 효과적인 보호방법을 제안하기 위하여 전원계통의 접지방식에 따른 서지보호기의 보호효과를 실험적으로 분석하였다. 또한 서지보호기의 효과적인 설치방법을 조사하고 제안하였다. 기존의 설비에 추가적으로 서지보호기를 설치하는 것은 서지보호기까지의 긴 접속선으로 인한 인덕턴스 때문에 높은 잔류전압이 나타난다. 서지보호기의 설치에 있어 두 접속선을 꼬는 방법이 급격하게 상승하는 과도과전압에 매우 효과적이다.